Plan Review Details - Permit 03041003
Plan Review Stops For Permit 03041003
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-07-21 Cont ID  
Sent By lmartine Date 2003-07-21 Time 16:57 Rev Time 1.00
Received By lmartine Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2003-04-25 Cont ID  
Sent By btrobaug Date 2003-07-21 Time 14:43 Rev Time 1.00
Received By lmartine Date   Time   Sent To E
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-07-21 Cont ID  
Sent By btrobaug Date 2003-07-21 Time 14:43 Rev Time 0.50
Received By btrobaug Date 2003-07-21 Time 14:36 Sent To B
Notes
2003-07-21 00:00:00TO LUIS ./WRT.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2003-04-25 Cont ID  
Sent By lmartine Date 2003-04-25 Time 12:45 Rev Time 1.00
Received By btrobaug Date 2003-04-25 Time 13:39 Sent To M
Notes
2003-04-25 00:00:00UNSAT
 ~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 PLEASE REDRAW THE PLANS TO REFLECT
 COMPLIANCE WITH THE FOLLOWING CODE
 ARTICLES, AND RESUBMIT FOR REVIEW.
  
 1} PLEASE LIST THE REQ'D BATH(S)
 CIRCUIT(S). PER 210-11-C-3
 MUST BE 20A AND #12AWG.
  
 2} PLEASE LIST THE REQ'D ARC
 FAULT PROTECTED CIRCUITS ON PANEL
 SCHEDULE OR NOTE ON PLANS FOR BRANCH
 CIRCUIT PROTECTION. PER 210-12
  
 3} PLEASE NOTE, EITHERMISSING
 LIGHTING AND/OR CLARIFY EGRESS LIGHTING
 PER 210-70 OF THE NEC.
  
 4} PLEASE SHOW ALL OUTLET SPACING
 TO MEET 2',6',12' RULE PER 210-52.
  
 5} PLEASE ADD SMOKE DETECTORS TO COMPLY
 WITH 8-1.4.2 NFPA-72.
  
 6} ADD OUTSIDE GFI TO COMPLY WITH
 210-52(E),IF THERE IS NONE.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-04-14 Cont ID  
Sent By shernand Date 2003-04-14 Time 13:45 Rev Time 0.00
Received By shernand Date 2003-04-14 Time 13:45 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-04-25 Cont ID  
Sent By btrobaug Date 2003-04-25 Time 14:01 Rev Time 0.40
Received By pkrauss Date 2003-04-25 Time 14:28 Sent To P
Notes
2003-04-25 00:00:00MECHANICAL PERMIT 03041007

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-04-26 Cont ID  
Sent By pkrauss Date 2003-04-25 Time 14:29 Rev Time 0.25
Received By kstevens Date 2003-04-26 Time 07:16 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-04-22 Cont ID  
Sent By shernand Date 2003-04-14 Time 13:46 Rev Time 0.00
Received By sgraham Date   Time   Sent To B
Notes
***NONE***