Plan Review Details - Permit 03040987
Plan Review Stops For Permit 03040987
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2003-07-29 Cont ID  
Sent By alange Date 2003-08-04 Time 13:09 Rev Time 0.00
Received By hpiskura Date 2003-07-29 Time 12:27 Sent To  
Notes
2003-07-29 00:00:00WINDOW/DOOR REVISION DATED 5/15/03.
 PROVIDE THE DESIGN PRESSURES FOR THE
 WINDOWS AND DOORS AND THE SIZES OF THE
 WINDOWS AND DOORS.
  
 THERE IS NO NOA FOR THE SLIDING GLASS
 DOORS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-05-13 Cont ID  
Sent By alange Date 2003-07-28 Time 11:00 Rev Time 0.00
Received By hpiskura Date 2003-05-13 Time 13:12 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2003-04-25 Cont ID  
Sent By hpiskura Date 2003-04-25 Time 11:37 Rev Time 0.00
Received By hpiskura Date 2003-04-25 Time 11:37 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-07-14 Cont ID  
Sent By dpalmer Date 2003-07-14 Time 12:14 Rev Time 0.25
Received By dpalmer Date 2003-07-14 Time 12:14 Sent To  
Notes
2003-07-14 00:00:00REV TO ADD STEAM UNIT ONLY. 30A

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-05-12 Cont ID  
Sent By shernand Date 2003-07-07 Time 10:19 Rev Time 0.33
Received By dpalmer Date 2003-05-12 Time 07:52 Sent To  
Notes
2003-05-12 00:00:00*********** PLANS REDLINED *********
  
 PLEASE SEE 210-52C-1
 PLEASE SEE 210-8A-6

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-04-23 Cont ID  
Sent By dpalmer Date 2003-04-23 Time 19:59 Rev Time 0.25
Received By dpalmer Date 2003-04-23 Time 19:59 Sent To  
Notes
2003-04-23 00:00:00********** PLANS REDLINED *******
  
  
 210-52C-1 KITCHEN COUNTERSPACE RECEPTS.
 210-8A-6 GFI PROTECTION FOR ALL KITCHEN
 RECEPTS SERVING COUNTERSPACE
 SD`S REQ`D INSIDE AND OUTSIDE ALL
 SLEEPING ROOMS. NFPA-72 8-1.4.2

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2003-05-27 Cont ID  
Sent By nmccray Date 2003-05-27 Time 13:38 Rev Time 0.00
Received By nmccray Date 2003-05-27 Time 13:38 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2003-04-25 Cont ID  
Sent By mcarsill Date 2003-04-25 Time 14:02 Rev Time 0.00
Received By mcarsill Date 2003-04-25 Time 14:02 Sent To  
Notes
2003-04-25 00:00:001) PLANS DO NOT INDICATE EXISTING
 ELECTRIC POWERED SMOKE DETECTORS. PLEASE
 DISPLAY EXISTING SMOKE DETECTORS OR
 INSTALL ONES IF NOT ALREADY PRESENT.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 659-8096,EXT.8497
 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2003-08-04 Cont ID  
Sent By alange Date 2003-08-04 Time 13:08 Rev Time 0.00
Received By alange Date 2003-08-04 Time 13:08 Sent To B
Notes
2003-08-04 00:00:00TO HP DESK

Review Stop I INCOMING/PROCESSING
Rev No 4 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By alange Date 2003-07-28 Time 11:00 Sent To  
Notes
2003-07-28 00:00:00TO HP DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-07-07 Cont ID  
Sent By shernand Date 2003-07-07 Time 10:19 Rev Time 0.00
Received By shernand Date 2003-07-07 Time 10:19 Sent To E
Notes
2003-07-07 00:00:00DP DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-05-08 Cont ID  
Sent By shernand Date 2003-05-08 Time 10:53 Rev Time 0.00
Received By shernand Date 2003-05-08 Time 10:53 Sent To  
Notes
2003-05-08 00:00:00COMM BOARD #32

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-04-14 Cont ID  
Sent By shernand Date 2003-04-14 Time 13:21 Rev Time 0.00
Received By shernand Date 2003-04-14 Time 13:21 Sent To  
Notes
2003-04-14 00:00:00COMM BOARD #20

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-05-27 Cont ID  
Sent By pkrauss Date 2003-05-27 Time 14:06 Rev Time 0.35
Received By pkrauss Date 2003-05-27 Time 13:58 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2003-05-03 Cont ID  
Sent By pkrauss Date 2003-05-03 Time 09:48 Rev Time 0.25
Received By pkrauss Date 2003-05-03 Time 09:48 Sent To  
Notes
2003-05-03 00:00:00 
 1.PLEASE PROVIDE DUCT SIZE OF THE
 TRUNK LINE TO LIVING RM (12 X 4 GRILLE),
 DUCT TO (8 X 4 GRILLE) AND DUCT TO THE
 MASTER BATH (8 X 8 GRILLE).
  
 2.PLEASE NOTE, PRIOR TO CONNECTING NEW
 DUCTWORK TO EXISTING, MAKE SURE EXISTING
 DUCT IS CLEAN.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 1 Status N Date 2003-04-26 Cont ID  
Sent By kstevens Date 2003-04-26 Time 09:54 Rev Time 0.25
Received By kstevens Date 2003-04-26 Time 09:54 Sent To  
Notes
2003-04-26 00:00:00NO PLUMBING PLANS SUBMITTED

Review Stop Z ZONING
Rev No 1 Status N Date 2003-05-27 Cont ID  
Sent By pkrauss Date 2003-05-27 Time 14:07 Rev Time 0.00
Received By pkrauss Date   Time   Sent To  
Notes
***NONE***