| Plan Review Stops For Permit 03040986 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2003-06-18 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-06-30 |
Time |
08:41 |
Rev Time |
0.50 |
| Received By |
lsmith |
Date |
2003-06-18 |
Time |
11:59 |
Sent To |
|
|
| Notes |
| 2003-06-18 00:00:00 | ****************FAILED*************** | | | | | | NO DETAIL SHOWN ON PLANS FOR | | | CONSTRUCTION OF RAISED WALL. | | | | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 805-6713 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2003-04-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-06-18 |
Time |
11:08 |
Rev Time |
0.50 |
| Received By |
sthyng |
Date |
2003-04-22 |
Time |
08:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2003-06-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-06-30 |
Time |
07:36 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2003-06-30 |
Time |
07:36 |
Sent To |
P |
|
| Notes |
| 2003-06-30 00:00:00 | *********** UNSAT ************** | | | | | | 1)NOTE: PLEASE CORRELATE ELECTRICAL | | | DIAGRAM WITH ALL EQUIPMENT BEING INSTALL | | | -ED. | | | PLEASE SEE PLAN, ONLY ONE PUMP SHOWN? | | | | | | PLEASE INCLUDE ALL WIRE, CONDUIT SIZES. | | | PLEASE INCLUDE LOAD CALCULATIONS WITH | | | NEW AND EXISTING LOADS AND SIZE OF | | | EXISTING SERVICE. | | | | | | PLEASE SEE LETTER ATTACHED FOR DESIGNER | | | OF RECORD. PLEASE NOTE, THIS IS REQ'D | | | UNDER FS 553.80(2)(B). | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION | | | FOR REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2003-06-18 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-19 |
Time |
15:36 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-06-18 |
Time |
11:06 |
Sent To |
B |
|
| Notes |
| 2003-06-18 00:00:00 | ***************** UNSAT ************ | | | | | | NOTES FROM PREVIOUS REVIEWS HAVE NOT | | | BEEN ADDRESS. | | | | | | PLEASE SEE THAT PLANS SUBMITTED DO NOT | | | CORRELATE WITH WORK DESCRIBE, NEW PUMPS | | | HEAT PUMP ETC ETC. | | | | | | PLEASE SEE LETTER ATTACHED REFERENCED TO | | | FS 553.80(2)(B). | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2003-05-27 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-06-17 |
Time |
12:11 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2003-05-27 |
Time |
13:37 |
Sent To |
|
|
| Notes |
| 2003-05-27 00:00:00 | UNSAT | | | ~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | SEE ATTACHED NOTE FROM PREVIOUS REVIEW. | | | NEED PLANS & AND CALC'S. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
N |
Date |
2003-04-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-04-22 |
Time |
11:04 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2003-04-22 |
Time |
11:03 |
Sent To |
|
|
| Notes |
| 2003-04-22 00:00:00 | SEPARATE PLANS AND PERMIT FOR ELECTRIC. | | | LOAD CALCS FOR HEAT PUMP. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-04-22 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-04-18 |
Time |
16:13 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2003-04-22 |
Time |
07:47 |
Sent To |
B |
|
| Notes |
| 2003-04-22 00:00:00 | ************ UNSAT ************** | | | | | | 1)NOTE: PLEASE SUBMIT SPEC/CUT SHEETS | | | FOR HEAT PUMP. | | | | | | 2)NOTE: PLEASE SHOW SIZE OF WIRING AND | | | METHOD ON WIRING/ELECTRICAL DIAGRAM. | | | | | | 3)NOTE: PLEASE SUBMIT LOAD CALCULATION | | | FOR EXISTING SERVICE AND NEW LOADS | | | ADDED. PLEASE ALSO SHOW SIZE OF EXSITING | | | SERVICE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-06-19 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-19 |
Time |
15:35 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-06-19 |
Time |
15:35 |
Sent To |
E |
|
| Notes |
| 2003-06-19 00:00:00 | DP DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-06-12 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-12 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-06-12 |
Time |
09:52 |
Sent To |
P |
|
| Notes |
| 2003-06-12 00:00:00 | PLUMBING REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-04-15 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-15 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-04-15 |
Time |
15:53 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2003-06-30 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-06-30 |
Time |
08:41 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2003-06-30 |
Time |
08:40 |
Sent To |
B |
|
| Notes |
| 2003-06-30 00:00:00 | REVISION OK - 3 SHEER DECENTS AND 1 NEW | | | PUMP FOR POOL |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2003-06-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-06-30 |
Time |
07:36 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2003-06-17 |
Time |
12:04 |
Sent To |
E |
|
| Notes |
| 2003-06-17 00:00:00 | DENIED | | | REFERENCE: FBC-2001 424.2 SWIMMING POOLS | | | | | | 1) SECTION 424.2.6.6.3, A MINIMUM OF TWO | | | SUCTION INLETS SHALL BE PROVIDED FOR | | | EACH PUMP IN THE INLET SYSTEM, SEPARATED | | | BY A MINIMUM OF 3 FEET OR LOCATED ON TWO | | | DIFFERENT PLANES ECT. - ONLY TWO DRAIN | | | ARE SHOWN ON PLANS. MINIMUM OF 4 MAIN | | | DRAINS REQUIRED. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 | | | (561) 805-6721 | | | FAX (561) 653-2692 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2003-04-22 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-12 |
Time |
09:52 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2003-04-22 |
Time |
09:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-04-18 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2003-04-17 |
Time |
12:07 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-04-18 |
Time |
16:09 |
Sent To |
E |
|
| Notes |
| 2003-04-18 00:00:00 | DENIED | | | REFERENCE: FBC-2001 424.2 SWIMMING POOLS | | | | | | A) PLEASE ADJUST YOUR NOTES, DETAILS, OR | | | SUBMITTALS TO REFLECT THE FOLLOWING IN- | | | FORMATION REQUIRED FOR PLAN REVIEW | | | 1) FBC-2001 424.2.14.1 SWIMMING POOL | | | WATER HEATERS SHALL BEAR THE LABEL OF A | | | RECOGNIZED TESTING AGENCY. MANUFACTURE | | | SHEETS REQUIRED. (SUBMITTAL) | | | 2) FBC-2001 424.2.14.2 WATER RETENTION, | | | PROVIDE A POSITIVE MEANS OF RETAINING | | | WATER IN THE HEATER WHEN PUMP IS SHUT | | | OFF. (MANUFACTURE CUT SHEETS SUBMITTAL) | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 | | | (561) 805-6721 | | | FAX (561) 653-2692 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-04-17 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-15 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
P |
|
| Notes |
|
|