Plan Review Details - Permit 03040986
Plan Review Stops For Permit 03040986
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2003-06-18 Cont ID  
Sent By kstevens Date 2003-06-30 Time 08:41 Rev Time 0.50
Received By lsmith Date 2003-06-18 Time 11:59 Sent To  
Notes
2003-06-18 00:00:00****************FAILED***************
  
 NO DETAIL SHOWN ON PLANS FOR
 CONSTRUCTION OF RAISED WALL.
  
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 805-6713

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2003-04-22 Cont ID  
Sent By dpalmer Date 2003-06-18 Time 11:08 Rev Time 0.50
Received By sthyng Date 2003-04-22 Time 08:48 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 5 Status F Date 2003-06-30 Cont ID  
Sent By dpalmer Date 2003-06-30 Time 07:36 Rev Time 0.33
Received By dpalmer Date 2003-06-30 Time 07:36 Sent To P
Notes
2003-06-30 00:00:00*********** UNSAT **************
  
 1)NOTE: PLEASE CORRELATE ELECTRICAL
 DIAGRAM WITH ALL EQUIPMENT BEING INSTALL
 -ED.
 PLEASE SEE PLAN, ONLY ONE PUMP SHOWN?
  
 PLEASE INCLUDE ALL WIRE, CONDUIT SIZES.
 PLEASE INCLUDE LOAD CALCULATIONS WITH
 NEW AND EXISTING LOADS AND SIZE OF
 EXISTING SERVICE.
  
 PLEASE SEE LETTER ATTACHED FOR DESIGNER
 OF RECORD. PLEASE NOTE, THIS IS REQ'D
 UNDER FS 553.80(2)(B).
  
 PLEASE SUBMIT THE ABOVE INFORMATION
 FOR REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2003-06-18 Cont ID  
Sent By shernand Date 2003-06-19 Time 15:36 Rev Time 0.50
Received By dpalmer Date 2003-06-18 Time 11:06 Sent To B
Notes
2003-06-18 00:00:00***************** UNSAT ************
  
 NOTES FROM PREVIOUS REVIEWS HAVE NOT
 BEEN ADDRESS.
  
 PLEASE SEE THAT PLANS SUBMITTED DO NOT
 CORRELATE WITH WORK DESCRIBE, NEW PUMPS
 HEAT PUMP ETC ETC.
  
 PLEASE SEE LETTER ATTACHED REFERENCED TO
 FS 553.80(2)(B).
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2003-05-27 Cont ID  
Sent By kstevens Date 2003-06-17 Time 12:11 Rev Time 0.33
Received By btrobaug Date 2003-05-27 Time 13:37 Sent To  
Notes
2003-05-27 00:00:00UNSAT
 ~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 SEE ATTACHED NOTE FROM PREVIOUS REVIEW.
 NEED PLANS & AND CALC'S.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718

Review Stop E ELECTRICAL
Rev No 2 Status N Date 2003-04-22 Cont ID  
Sent By dpalmer Date 2003-04-22 Time 11:04 Rev Time 0.25
Received By dpalmer Date 2003-04-22 Time 11:03 Sent To  
Notes
2003-04-22 00:00:00SEPARATE PLANS AND PERMIT FOR ELECTRIC.
 LOAD CALCS FOR HEAT PUMP.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2003-04-22 Cont ID  
Sent By kstevens Date 2003-04-18 Time 16:13 Rev Time 0.25
Received By dpalmer Date 2003-04-22 Time 07:47 Sent To B
Notes
2003-04-22 00:00:00************ UNSAT **************
  
 1)NOTE: PLEASE SUBMIT SPEC/CUT SHEETS
 FOR HEAT PUMP.
  
 2)NOTE: PLEASE SHOW SIZE OF WIRING AND
 METHOD ON WIRING/ELECTRICAL DIAGRAM.
  
 3)NOTE: PLEASE SUBMIT LOAD CALCULATION
 FOR EXISTING SERVICE AND NEW LOADS
 ADDED. PLEASE ALSO SHOW SIZE OF EXSITING
 SERVICE.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-06-19 Cont ID  
Sent By shernand Date 2003-06-19 Time 15:35 Rev Time 0.00
Received By shernand Date 2003-06-19 Time 15:35 Sent To E
Notes
2003-06-19 00:00:00DP DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-06-12 Cont ID  
Sent By shernand Date 2003-06-12 Time 09:52 Rev Time 0.00
Received By shernand Date 2003-06-12 Time 09:52 Sent To P
Notes
2003-06-12 00:00:00PLUMBING REVISION

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-04-15 Cont ID  
Sent By shernand Date 2003-04-15 Time 15:53 Rev Time 0.00
Received By shernand Date 2003-04-15 Time 15:53 Sent To Z
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status P Date 2003-06-30 Cont ID  
Sent By kstevens Date 2003-06-30 Time 08:41 Rev Time 0.33
Received By kstevens Date 2003-06-30 Time 08:40 Sent To B
Notes
2003-06-30 00:00:00REVISION OK - 3 SHEER DECENTS AND 1 NEW
 PUMP FOR POOL

Review Stop P PLUMBING
Rev No 3 Status F Date 2003-06-17 Cont ID  
Sent By dpalmer Date 2003-06-30 Time 07:36 Rev Time 0.33
Received By kstevens Date 2003-06-17 Time 12:04 Sent To E
Notes
2003-06-17 00:00:00DENIED
 REFERENCE: FBC-2001 424.2 SWIMMING POOLS
  
 1) SECTION 424.2.6.6.3, A MINIMUM OF TWO
 SUCTION INLETS SHALL BE PROVIDED FOR
 EACH PUMP IN THE INLET SYSTEM, SEPARATED
 BY A MINIMUM OF 3 FEET OR LOCATED ON TWO
 DIFFERENT PLANES ECT. - ONLY TWO DRAIN
 ARE SHOWN ON PLANS. MINIMUM OF 4 MAIN
 DRAINS REQUIRED.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377
 (561) 805-6721
 FAX (561) 653-2692

Review Stop P PLUMBING
Rev No 2 Status P Date 2003-04-22 Cont ID  
Sent By shernand Date 2003-06-12 Time 09:52 Rev Time 0.25
Received By kstevens Date 2003-04-22 Time 09:49 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-04-18 Cont ID  
Sent By sgraham Date 2003-04-17 Time 12:07 Rev Time 0.50
Received By kstevens Date 2003-04-18 Time 16:09 Sent To E
Notes
2003-04-18 00:00:00DENIED
 REFERENCE: FBC-2001 424.2 SWIMMING POOLS
  
 A) PLEASE ADJUST YOUR NOTES, DETAILS, OR
 SUBMITTALS TO REFLECT THE FOLLOWING IN-
 FORMATION REQUIRED FOR PLAN REVIEW
 1) FBC-2001 424.2.14.1 SWIMMING POOL
 WATER HEATERS SHALL BEAR THE LABEL OF A
 RECOGNIZED TESTING AGENCY. MANUFACTURE
 SHEETS REQUIRED. (SUBMITTAL)
 2) FBC-2001 424.2.14.2 WATER RETENTION,
 PROVIDE A POSITIVE MEANS OF RETAINING
 WATER IN THE HEATER WHEN PUMP IS SHUT
 OFF. (MANUFACTURE CUT SHEETS SUBMITTAL)
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377
 (561) 805-6721
 FAX (561) 653-2692

Review Stop Z ZONING
Rev No 1 Status P Date 2003-04-17 Cont ID  
Sent By shernand Date 2003-04-15 Time 15:53 Rev Time 0.00
Received By sgraham Date   Time   Sent To P
Notes
***NONE***