| Plan Review Stops For Permit 03040853 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2003-05-20 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-05-20 |
Time |
14:31 |
Rev Time |
1.00 |
| Received By |
sthyng |
Date |
2003-05-20 |
Time |
14:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-05-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-05-19 |
Time |
07:37 |
Rev Time |
4.00 |
| Received By |
sthyng |
Date |
2003-04-29 |
Time |
10:01 |
Sent To |
|
|
| Notes |
| 2003-04-29 00:00:00 | **********CORRECTIONS************ | | | | | | 1.)BEFORE A PERMIT TO CONSTRUCT MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 2.)PROVIDE PRODUCT APPROVALS FOR THE | | | ROOF COVERINGS. | | | | | | 3.)FBC 104.3.1.1, PROVIDE A WALL | | | SECTION FROM FOUNDATION THROUGH ROOF, | | | INCLUDING FIRESTOP, DRYWALL, SHEATHING, | | | INSULATION, ROOF AND STUCCO. | | | | | | 4.)PLANS WITH AN ARCHITECT TITLE BLOCK | | | ARE REQUIRED TO BE SEALED, SIGNED AND | | | DATED. | | | | | | 5.)GIVE DIMENSIONS FOR THE EXISTING | | | FOOTER AND NEW FOOTERS. | | | | | | 6.)FBC 11-4.22.2, PROVIDE A BATHROOM | | | WITH A DOOR WITH A 29" CLEAR OPENING. | | | | | | 7.)PROVIDE A WINDOW AND DOOR SCHEDULE. | | | | | | 8.)FBC 705.3.2, DRAFTSTOPPING | | | REQUIRED. | | | | | | 9.)FBC 905.2.2, SMOKE DETECTOR | | | REQUIRED. | | | | | | 10.) ADDITIONAL FEES DUE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2003-05-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-05-19 |
Time |
07:37 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2003-05-19 |
Time |
07:37 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-04-24 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-05-15 |
Time |
16:14 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2003-04-24 |
Time |
12:20 |
Sent To |
M |
|
| Notes |
| 2003-04-24 00:00:00 | UNSAT | | | ~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | 1} PLEASE NOTE THAT ALL PLANS | | | DRAWN BY AN ARCHITECT/ENGINEER CONTAIN- | | | ING A TITLE BLOCK, MUST BE SIGNED, | | | DATED AND SEALED BY THE ARCH/ENGINEER OF | | | RECORD. PER FS/FAC 481.221 & 471.025 | | | ALL SHEETS,SEE 1,2 & 3. | | | | | | 2} PLEASE NOTE RECEPTACLES SERVING | | | KITCHEN COUNTERTOPS MUST COMPLY WITH | | | 210-52(C)(1) AND 210-8(A)(6). | | | | | | 3} ALL BATH RECEPTACLES MUST COMPLY WITH | | | 210-8(A)(1). | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-05-15 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-05-15 |
Time |
16:14 |
Rev Time |
0.00 |
| Received By |
sthyng |
Date |
2003-05-15 |
Time |
16:14 |
Sent To |
E |
|
| Notes |
| 2003-05-15 00:00:00 | TO DP DESK (BT OUT) |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-04-21 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-21 |
Time |
13:21 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-04-21 |
Time |
13:21 |
Sent To |
E |
|
| Notes |
| 2003-04-21 00:00:00 | GAVE COPY OF APPLIC. TO LOU HATTEN, PER | | | COMMENTS AT BOTTOM. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-04-11 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2003-04-17 |
Time |
10:39 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-04-11 |
Time |
09:18 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2003-04-28 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-04-24 |
Time |
12:37 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2003-04-28 |
Time |
15:17 |
Sent To |
B |
|
| Notes |
| 2003-04-28 00:00:00 | MECHANICAL PERMIT 03040853 - | | | AC WAS UPGRADED UNDER MECHANICAL PERMIT | | | 99100149, ADDITION WAS TAKEN INTO | | | ACCOUNT WHEN AC SYSTEM WAS UPGRADED. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2003-04-23 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2003-04-23 |
Time |
18:30 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2003-04-23 |
Time |
18:29 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-04-17 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-11 |
Time |
09:18 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
I |
|
| Notes |
|
|