| Plan Review Stops For Permit 03040755 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
29 |
Status |
P |
Date |
2005-02-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-02-10 |
Time |
09:02 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2005-02-10 |
Time |
09:02 |
Sent To |
PC |
|
| Notes |
| 2005-02-10 00:00:00 | REVISED SHEETS AP A5.02, AP A6.01 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
28 |
Status |
P |
Date |
2004-08-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-08-24 |
Time |
08:46 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2004-08-24 |
Time |
08:46 |
Sent To |
|
|
| Notes |
| 2004-08-24 00:00:00 | SUBMITTALS - STRUC.DETAIL, TRUSS | | | | | | NEW GROUT FOR NEW OPENING, (FIX FOR | | | OPENING BIGGER THAN 12") | | | | | | TRUSS ENGINEERING, PICNIC PAVILLION AND | | | MAIL KIOSK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
27 |
Status |
P |
Date |
2004-07-27 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-05 |
Time |
16:45 |
Rev Time |
0.50 |
| Received By |
alange |
Date |
2004-07-27 |
Time |
15:15 |
Sent To |
|
|
| Notes |
| 2004-07-27 00:00:00 | SUBMITTAL OK, STUCCO |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
26 |
Status |
P |
Date |
2004-05-14 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-22 |
Time |
09:11 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2004-05-14 |
Time |
16:57 |
Sent To |
|
|
| Notes |
| 2004-05-14 00:00:00 | TRUSS REPAIRS PREPARED BY JULIUS LEE, PE | | | DATED 4/27/4 | | | SHEETS 65, 62, 91, 90, 88, 89, 87, 86 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
25 |
Status |
F |
Date |
2004-05-04 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-12 |
Time |
14:24 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-05-04 |
Time |
16:50 |
Sent To |
|
|
| Notes |
| 2004-05-04 00:00:00 | ****CORRECTIONS**** | | | RINKER BLOCK SUBMITTAL | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 | | | | | | DOCUMENTS PREPARED BY AN ENGINEER AND | | | FILED FOR PUBLIC RECORD ARE TO HAVE AN | | | ORIGINAL SEAL AND SIGNATURE.TITLE | | | BLOCK REQUIRED INCLUDING PRINTED LICENSE | | | NUMBER, FAC61G15-23.002. | | | | | | CC:DON NEELY |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
24 |
Status |
P |
Date |
2004-04-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-04-19 |
Time |
11:43 |
Rev Time |
0.25 |
| Received By |
shill |
Date |
2004-04-19 |
Time |
11:43 |
Sent To |
|
|
| Notes |
| 2004-04-19 00:00:00 | LETTER IN RESPONSE TO DOOR LOUVER | | | CORRECTION PREPARED BY BJ&K DATED 4/7/4 | | | | | | LETTER IN RESPONSE TO CABINET CORRECTION | | | | | | STEEL SHOPS (BEAM & COLUMN) |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
23 |
Status |
P |
Date |
2004-04-01 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-08 |
Time |
08:05 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-04-01 |
Time |
12:08 |
Sent To |
|
|
| Notes |
| 2004-04-01 00:00:00 | SHORING INSPECTION LETTER, 5TH FLOOR | | | PREPARED BY CALVIN FOONG, PE AND | | | LETTER FROM BJ&K |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
22 |
Status |
P |
Date |
2004-03-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-03-22 |
Time |
14:41 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-03-22 |
Time |
14:41 |
Sent To |
|
|
| Notes |
| 2004-03-22 00:00:00 | SUBMITTALS | | | | | | MASONRY SPECS | | | WEDGE ANCHOR SPECS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
21 |
Status |
P |
Date |
2004-03-22 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-22 |
Time |
14:26 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-03-22 |
Time |
13:10 |
Sent To |
|
|
| Notes |
| 2004-03-22 00:00:00 | TRUSS DRAWINGS PREPARED BY JULIUS LEE,PE | | | 2/12/04 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
20 |
Status |
P |
Date |
2004-03-18 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-19 |
Time |
16:15 |
Rev Time |
0.25 |
| Received By |
shill |
Date |
2004-03-18 |
Time |
17:19 |
Sent To |
|
|
| Notes |
| 2004-03-18 00:00:00 | SHORING 4TH FLOOR INSPECTION LETTER | | | PREPARED BY CALVIN FOONG, PE |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
19 |
Status |
P |
Date |
2004-03-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-03-06 |
Time |
17:31 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-03-06 |
Time |
17:31 |
Sent To |
|
|
| Notes |
| 2004-03-06 00:00:00 | PRECAST WINDOW SILL SPECS | | | CASTCRETE |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
18 |
Status |
P |
Date |
2004-03-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-03-05 |
Time |
08:08 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-03-05 |
Time |
08:08 |
Sent To |
|
|
| Notes |
| 2004-03-05 00:00:00 | SHORING/RESHORE LETTER, 3RD FLOOR DECK | | | PREPARED BY CALVIN FOONG, PE 3/3/4 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
17 |
Status |
P |
Date |
2004-03-01 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-03-01 |
Time |
18:01 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2004-03-01 |
Time |
18:01 |
Sent To |
|
|
| Notes |
| 2004-03-01 00:00:00 | SUBMITTALS - BONSAL GROUT, POWER | | | FASTENERS FOR DRILL & EPOXY |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
16 |
Status |
F |
Date |
2004-02-24 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-25 |
Time |
14:51 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2004-02-24 |
Time |
16:33 |
Sent To |
|
|
| Notes |
| 2004-02-24 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)DRAWINGS PREPARED BY AND ENGINEER | | | ARE TO HAVE A TITLE BLOCK WITH THE | | | FOLLOWING: | | | AUTH # OF FIRM | | | PRINTED NAME & LIC # OF PERSON SEALING | | | THE PLAN | | | ADDRESS | | | | | | POWER SYSTEMS ENGINEERING IS REQUIRED | | | TO HAVE AN AUTHORIZATION NUMBER FROM | | | FBPE TO PRACTICE ENGINEERING IN FLORIDA. | | | SOME SHEETS WERE SUBMITTED WITHOUT | | | ANY TITLE BLOCK.PLEASE READ FAC | | | 61G15-23.002. | | | | | | | | | CC:DON NEELY |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
15 |
Status |
P |
Date |
2004-02-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-02-20 |
Time |
10:54 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-02-20 |
Time |
10:54 |
Sent To |
|
|
| Notes |
| 2004-02-20 00:00:00 | SHORING INSPECTION LETTERS, 2ND FLOOR, | | | PREPARED BY CALFIN FOONG, PE AND CAPRI | | | ENGINEERING, PE |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
14 |
Status |
F |
Date |
2004-02-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-02-19 |
Time |
12:11 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-02-19 |
Time |
12:11 |
Sent To |
|
|
| Notes |
| 2004-02-19 00:00:00 | ***CORRECTIONS*** | | | | | | TRASH, ELEC METER, PHONE/CABLE, ELEV, | | | EQUIP AND FACP ROOM DOORS | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)THE NOTATION ON SHEET 2 TO CUT | | | THE DOORS TO INSTALL LOUVERS IS NOT | | | COVERED BY THE PRODUCT APPROVALS | | | SUBMITTED WITH THE BUILDING PERMIT | | | APPLICATION. | | | | | | CC:DON NEELY |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
13 |
Status |
P |
Date |
2004-02-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-02-19 |
Time |
11:50 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-02-19 |
Time |
11:50 |
Sent To |
|
|
| Notes |
| 2004-02-19 00:00:00 | STAIR DOORS SUBMITTAL |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
12 |
Status |
P |
Date |
2004-02-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-02-11 |
Time |
15:54 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-02-11 |
Time |
15:54 |
Sent To |
|
|
| Notes |
| 2004-02-11 00:00:00 | REVISED SHORING PLAN DATED 2/10/04 | | | FILED W/03040756 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
11 |
Status |
P |
Date |
2004-02-09 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-09 |
Time |
16:30 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2004-02-09 |
Time |
11:20 |
Sent To |
|
|
| Notes |
| 2004-02-09 00:00:00 | SHORING & RESHORINGBY CALVIN FOONG | | | PE DATED 2/4/04 (ALSO 03040756) |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
10 |
Status |
P |
Date |
2004-01-30 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-06 |
Time |
11:58 |
Rev Time |
0.25 |
| Received By |
shill |
Date |
2004-01-30 |
Time |
15:16 |
Sent To |
|
|
| Notes |
| 2004-01-30 00:00:00 | ELEVATION TOP OF EXPANSION JOINTS | | | CRAIG A SMITH & ASSOCIATES |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
9 |
Status |
P |
Date |
2004-01-29 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-30 |
Time |
11:08 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-01-29 |
Time |
18:31 |
Sent To |
|
|
| Notes |
| 2004-01-29 00:00:00 | 4000 PSI CONCRETE MIX AND ADMIXTURES | | | RINKER MATERIALS (UNDERMINED FOOTINGS) |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
F |
Date |
2004-01-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-01-28 |
Time |
11:42 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2004-01-28 |
Time |
11:42 |
Sent To |
|
|
| Notes |
| 2004-01-28 00:00:00 | *****CORRECTIONS***** | | | | | | ELEVATION CERTIFICATE PREPARED BY CRAIG | | | A. SMITH & ASSOCIATES | | | | | | 1.)THE ELEVATION CERTIFICATE IS FOR | | | "BUILDING 1" WITH A PROJECT NUMBER. | | | PLEASE REFER TO AN ADDRESS AND PERMIT | | | NUMBER. | | | | | | CC:DON NEELY |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
F |
Date |
2004-01-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-01-28 |
Time |
11:29 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2004-01-28 |
Time |
11:29 |
Sent To |
|
|
| Notes |
| 2004-01-28 00:00:00 | ****CORRECTIONS***** | | | | | | CABINET SHOP DRAWINGS PREPARED BY AC | | | CABINETRY CORP 11/25/03 | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)THE SUPPORT BRACKETS (FOR | | | ACCESSIBILITY) HAVE DIMENSIONS NOT | | | CONSISTENT WITH YOUR APPROVED.THEY | | | DO NOT CONFORM TO ANSI 1986 (SEE | | | ATTACHED).TO CHANGE THIS SIZE, SUBMIT | | | AS A REVISION FROM THE ARCHITECT, NOT | | | AS A SHOP DRAWING, FOR REVIEW FOR CODE | | | COMPLIANCE. | | | | | | CC:DON NEELY |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2004-01-22 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-27 |
Time |
12:24 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-01-22 |
Time |
19:51 |
Sent To |
|
|
| Notes |
| 2004-01-22 00:00:00 | SHOP DRAWINGS, FILLED CELLS & BEAMS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2003-12-30 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-20 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-12-30 00:00:00 | TRUSS DRAWINGS FROM PRODUCTION TRUSS AND | | | FABRICATION ARE NOT SIGNED AND SEALED. | | | | | | THE ARCHITECTURAL REVISIONS ARE NOT | | | SIGNED AND SEALED AND MUST BE SUBMITTED | | | AS REVISIONS AND THE FEES PAID. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2003-12-22 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2003-12-22 |
Time |
16:16 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-12-22 |
Time |
16:16 |
Sent To |
|
|
| Notes |
| 2003-12-22 00:00:00 | BUILDING/ELECTRICAL/PLUMBING REVISION | | | SUBMITTED ON 11/10/03 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2003-09-05 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-12 |
Time |
14:26 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-12-22 |
Time |
16:12 |
Sent To |
|
|
| Notes |
| 2003-12-22 00:00:00 | PASSED BY H. PISKURA ON 9/4/03 SEE BELOW | | 2003-09-04 00:00:00 | PROVISO: | | | | | | THE GENERAL NOTES ON THE FIRE | | | PROTECTIONPLANS, SHEET FP 13.01 HAVE | | | SEVERAL REFERENCES TO NFPA 13R FOR THE | | | DESIGN STANDARD.THIS DESIGN MUST BE | | | AN NFPA 13 DESIGN IN ITS ENTIRETY IN | | | ACCORDANCE WITH FBC 903.2. | | | | | | ALSO THE FLORIDA BUILDING CODE INVOKES | | | NFPA 13-99 NOT THE 2000 EDITION | | | DECLARED.PLEASE REVISE AS NECESSARY | | | AND ENSURE COMPLIANCE WITH THE 1999 | | | EDITION. | | | | | | SHEET FP 13.02 SHOWS A 6" WAFER CHECK | | | VALVE ON THE SUCTION SIDE OF THE PUMP | | | WITHIN TEN PIPE DIAMETERS OF THE FLANGE. | | | SEE NFPA 20-99 SECTION 2-21.3. | | | | | | SEE NFPA 13-99 CHAPTER 8 FOR DESIGN | | | PLAN AND CALCULATION CRITERIA. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2003-06-26 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-06-26 |
Time |
10:10 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-06-25 |
Time |
14:26 |
Sent To |
|
|
| Notes |
| 2003-06-26 00:00:00 | SECOND PAID PLAN REVIEW, NOT A PERMIT | | | APPLICATION. | | | | | | COMMENTS ARE APPLICABLE TO BOTH | | | BUILDING TYPES. | | | | | | THE TRESHOLD INSPECTION PLAN MUST BE | | | SIGNED, SEALED AND DATED WHEN SUBMITTED | | | FOR PERMIT APPLICATION.THE STATEMENT | | | CONTAINED IN FBC 105.13.4.4 MUST APPEAR | | | ON THE PERMIT PLANS. | | | | | | ADVISORY NOTE:THE U904 THREE HOUR FIRE | | | RATED MASONRY WALL SYSTEM REQUIRES | | | BLOCKS WITH UL CLASSIFICATION.THERE | | | ARE FEW IF ANY MANUFACTURERS IN THIS | | | AREA THAT PROVIDE UL CLASSIFICATION. | | | | | | SHEET S3.01 GENERAL NOTE #3 DECLARES | | | COMPONENT AND CLADDING PRESSURES OF | | | +37.1 AND -48.4.THE "ROOF FASTENING | | | ZONE" SHOWS 4' AND 5' FOR ZONE 3. | | | SHEET 3.02 DECLARES A "BASIC PRESSURE" | | | FROM TABLE 1606.2A AS P=38.5 PSF.THE | | | TABLE WITH THE COMPONENT AND CLADDING | | | PRESSURES FOR OPENINGS IN WALLS CALLS | | | OUT AN INTERIOR ZONE AND EDGE STRIP. | | | THIS TABLE HAS A COEFFICIENT OF 1.10 | | | AND LIST OF VALUES.THE ARCHITECT'S | | | RESPONSE LETTER DATED 5/28/03 STATED | | | THAT THE SIMPLIFIED WINDLOAD METHOD IN | | | FBC 1606.2 WAS TO BE USED. | | | | | | WHERE ARE THE PRESSURES IN GENERAL NOTE | | | # 3 TO BE APPLIED?HOW WERE THEY | | | DETERMINED? | | | | | | TABLE 1606.2A IS THE TABLE FOR THE MAIN | | | WIND FORCE RESISTING SYSTEM, NOT | | | COMPONENTS AND CLADDING.FBC 1606.2 | | | DOES NOT USE A "BASIC PRESSURE" SUCH AS | | | THAT DECLARED AS "P= 38 PSF."SEE FBC | | | 1606.2.2.1. | | | | | | WHERE IS THE DETERMINATION FOR THE ZONES | | | 1 THROUGH 5?SEE FBC 1606.2.3. | | | | | | AS AN EXAMPLE: SEE FBC TABLE 1606.2B, | | | UNDER HEADING "WALL" ZONE 5, EFFECTIVE | | | WIND AREA 20 SF, READ ACROSS TO COLUMN | | | NUMBERED 140 MPH, TO FIND 33.7 AND | | | -44.0.SEE FOOTNOTE 2 TO TABLE 1606.2B. | | | | | | GO TO TABLE 1606.2D, USING A MEAN ROOF | | | HEIGHT OF 50' FIND A COEFFICIENT OF | | | 1.16 TO BE USED FOR EXPOSURE B. | | | | | | 1.16 X -44.0 = -51.04.THIS DOES NOT | | | AGREE WITH THE NUMBERS IN THE TABLE ON | | | SHEET S3.02 OR THE GENERAL NOTE #3. | | | | | | WILL THERE BE ANY TESTS REQUIRED FOR THE | | | REINFORCED MASONRY?SECTION 04000 OF | | | THE CITED PROJECT MANUAL DOES NOT SPEAK | | | TO FREQUENCY OF GROUT TESTS, IF ANY, | | | PRISM TESTS, IF ANY OR EVEN | | | MANUFACTURER'S CERTIFICATION.THERE | | | ARENO QUALIFICATIONS FOR HEIGHTS OF | | | GROUT LIFT, CLEAN OUT, CORE SIZE OR ANY | | | SIGNIFICANT PORITION OF THE CRITERIA | | | CONTAINED IN ACI 530-99/ASCE 5-99/TMS | | | 402-99, AS NOTED IN FBC 2103.1. | | | | | | THE DRAFTSTOPPING ON SHEET A5.08 DOES | | | NOT APPEAR TO BE EFFECTIVELY PLACED. | | | PLEASE SEE FBC 2305.2.3 EXCEPTION #3 | | | FOR BEST APPLICATION. | | | | | | THE ENERGY CODE CALCULATIONS SHOULD BE | | | ON FORM 400.SEE FBC 13-400.0 AND | | | 13-101.2.1.ENSURE ALL SIGNATURES AS | | | REQUIRED ON THAT FORM ARE PROVIDED. | | | | | | SHEET A7.01 SHOWS A SLAB RECESS OF | | | 3/4",THE CITY HAS AMENDED THIS CODE | | | SECTION AND REQUIRES 1.5".PLEASE | | | REVISE AS NECESSARY. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-04-29 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-04-28 |
Time |
16:22 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-04-25 |
Time |
14:21 |
Sent To |
|
|
| Notes |
| 2003-04-29 00:00:00 | THESE WILL BE THRESHOLD BUILDINGS AND | | | MUST COMPLY WITH FBC 105.13 AND FS 553. | | | | | | SHEET S4.02 ARE THE THIRD THROUGH FIFTH | | | FLOORS TO BE ASSUMED THE SAME AS THE | | | SECOND?PLEASE CLARIFY DESIGN INTENT | | | THROUGHOUT, INCLUDING THE ARCHITECTURAL | | | PAGES.SEE FBC 104.2 AND THE LIST IN | | | FBC 104.3.1.1 FOR PERMIT PLAN | | | INFORMATION. | | | | | | SHEET S3.01, HOW WERE THE COMPONENT AND | | | CLADDING PRESSURES OF +33.7 AND -44.0 | | | DETERMINED FOR BUILDINGS OF THIS | | | HEIGHT. | | | | | | WILL THERE BE ANY TEST REQUIEMENTS OF | | | THE REINFORCED MASONRY? | | | | | | SHEET S3.02 DECLARES A 130 MPH WIND | | | SPEED, WEST PALM BEACH IS IN AN 140 MPH | | | ZONE. | | | | | | SHEET S3.02 CITES COMPONENT AND CLADDING | | | PRESSURES FROM FIGURE (TABLE) 1606.2B. | | | IT APPEARS THE FACTORS FROM 1606.2D | | | HAVE NOT BEEN APPLIED AND THE ZONES | | | SHOWN ON SHEET S3.01 ARE NOT CORRECT | | | FOR THESE BUILDINGS.FURTHER, THESE | | | BUILDINGS DO NOT APPEAR TO HAVE THE | | | SYMMETRY OF A SIMPLE DIAPHRAGM BUILDING | | | AS PROVIDED FOR IN FBC 1606.2.1 AND | | | SHOULD BE DESIGNED TO THE WIND | | | PROVISIONS OF ASCE 7-98. | | | | | | THE WOOD TRUSS NOTES ON S3.01 CITE AN | | | NDS STANDARD FOR DESIGN.SEE FBC | | | 2309.2 FOR MANDATORY DESIGN | | | SPECIFICATIONS AND FBC TABLE 1604.1 FOR | | | MINIMUM LIVE LOAD REQUIREMENTS. | | | | | | SHEET A9.01, THE STAIR DOORS SHOWN AS | | | #15 ARE REQUIRED TO BE 90 MINUTE, SEE | | | FBC TABLE 705.1. | | | | | | DRAFTSTOPPING OF THE ATTIC SPACE IN | | | ACCORDANCE WITH FBC 2305.2.3 IS | | | REQUIRED. | | | | | | SHOW THE ATTIC ACCESS, FBC 2309.6 AND | | | VENTILATION REQUIREMENTS OF FBC 2309.7, | | | INCLUDE FREE AREA OF ANY SCREEN VENTS. | | | | | | SHOW THE DESIGN LOADS FOR THE HAND AND | | | GUARD RAILS.SEE FBC 1608.2. | | | | | | BEFORE A PERMIT TO CONSTRUCT MAY BE | | | ISSUED IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY THE PERMIT PLANS STAMPED | | | BY THAT OFFICE AND A COPY OF THE PAID | | | RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. CALL 561-233-5025 FOR MORE | | | INFORMATION. | | | | | | IF PRODUCT ACCEPTANCE AND/OR TEST | | | REPORTS FOR THE DOORS, WINDOWS AND ROOF | | | COVERINGS ARE NOT INCLUDED WITH THE | | | PERMIT APPLICATION, SEPARATE PERMITS | | | AND ADDITIONAL FEES WILL BE REQUIRED. | | | | | | PERMIT INFORMATION, PLANS, | | | SPECIFICATIONS, ETC. ARE TO BE PROVIDED | | | TO THE CITY IN TRIPLICATE FOR THRESHOLD | | | BUILDINGS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
8 |
Status |
P |
Date |
2004-05-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-05-08 |
Time |
07:08 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-05-08 |
Time |
07:08 |
Sent To |
|
|
| Notes |
| 2004-05-08 00:00:00 | REV'S STAMPED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
P |
Date |
2004-04-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-04-23 |
Time |
07:21 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2004-04-23 |
Time |
07:21 |
Sent To |
|
|
| Notes |
| 2004-04-23 00:00:00 | OK,PLANS STAMPED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
|
Date |
2004-04-06 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-04-06 |
Time |
08:34 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2004-04-06 |
Time |
08:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2004-02-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-02-02 |
Time |
07:20 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2004-02-02 |
Time |
07:19 |
Sent To |
|
|
| Notes |
| 2004-02-02 00:00:00 | **** UNSAT **** | | | | | | SEE NOTES UNDER 03040756 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2003-11-17 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-11-17 |
Time |
16:36 |
Rev Time |
0.25 |
| Received By |
btrobaug |
Date |
2003-11-17 |
Time |
16:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2003-09-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-09-09 |
Time |
19:53 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2003-09-09 |
Time |
19:53 |
Sent To |
|
|
| Notes |
| 2003-09-09 00:00:00 | ELECTRICAL PLANS OK,STAMPED AND SIGNED | | | OFF. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2003-06-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-06-24 |
Time |
08:23 |
Rev Time |
2.00 |
| Received By |
dpalmer |
Date |
2003-06-24 |
Time |
08:22 |
Sent To |
|
|
| Notes |
| 2003-06-24 00:00:00 | PLEASE SEE NOTES, UNDER 03040756 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-04-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-04-29 |
Time |
18:13 |
Rev Time |
2.00 |
| Received By |
dpalmer |
Date |
2003-04-29 |
Time |
18:13 |
Sent To |
|
|
| Notes |
| 2003-04-29 00:00:00 | ********** UNSAT ********* | | | | | | PLEASE SEE NOTES UNDER #03040756 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
4 |
Status |
P |
Date |
2003-11-24 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2003-11-24 |
Time |
08:45 |
Rev Time |
0.50 |
| Received By |
mamini |
Date |
2003-11-24 |
Time |
08:45 |
Sent To |
|
|
| Notes |
| 2003-11-24 00:00:00 | PASSED: | | | 1. SEE PERMIT # 03111160 FOR UNDERGROUND | | | UTILITIES AND SITE WORK. | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
P |
Date |
2003-09-08 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2003-09-08 |
Time |
11:38 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2003-09-08 |
Time |
11:37 |
Sent To |
|
|
| Notes |
| 2003-09-08 00:00:00 | PASSED WITH PROVISOS: | | | 1. SEE REVIEW COMMENTS UNDER PERMIT # | | | 03040754 DATED 9-8-03. | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
F |
Date |
2003-06-05 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2003-06-05 |
Time |
14:29 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2003-06-05 |
Time |
14:29 |
Sent To |
|
|
| Notes |
| 2003-06-05 00:00:00 | FAILED: | | | 1. SEE REVIEW COMMENT UNDER PERMIT # | | | 0304074 DATED 6-05-03. | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2003-04-16 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2003-04-16 |
Time |
11:31 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2003-04-16 |
Time |
11:30 |
Sent To |
|
|
| Notes |
| 2003-04-16 00:00:00 | FAILED: | | | 1. SEE REVIEW COMMENTS UNDER PERMIT # | | | 03040754. (PLAN CHECK) | | | IF ANY QUESTION PLEASE CONTACT 659-8096 | | | EXT. 8492 MOHAMMAD R. AMINI |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
7 |
Status |
P |
Date |
2004-05-10 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2004-05-10 |
Time |
12:08 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2004-05-10 |
Time |
12:07 |
Sent To |
|
|
| Notes |
| 2004-05-10 00:00:00 | REVISION 5-04-04 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
6 |
Status |
|
Date |
2004-04-30 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-04-30 |
Time |
12:14 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-04-30 |
Time |
12:14 |
Sent To |
|
|
| Notes |
| 2004-04-30 00:00:00 | 1) THE ENTRY SIGN LOCATED NEAR THE | | | OPENING SHALL BE IN ADDITION TO THE | | | SIGN REQUIRED ON EXECUTIVE CENTER | | | DRIVE TO DIRECT EMERGENCY SERVICES TO | | | THE TWO APARTMENT BUILDINGS LOCATED | | | BEHIND THE EXISTING CLEAR LAKE | | | COLONY. | | | | | | 2) END OF LINE DEVICES SHOWN ON FIRE | | | ALARM SYSTEM WIRING. THE FIRE ALARM | | | SYSTEMS SHALL BE CLASS A, STYLE D, OR | | | FULLY ADDRESSABLE. | | | | | | 3) NFPA 13R IS REFERENCED ON PLANS. | | | NFPA 13R SYSTEMS ARE FOR RESIDENTIAL | | | BUILDINGS OF FOUR OR LESS STORIES. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
P |
Date |
2004-01-29 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2004-01-29 |
Time |
15:02 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2004-01-29 |
Time |
15:02 |
Sent To |
|
|
| Notes |
| 2004-01-29 00:00:00 | 1) ENTRANCE SIGN SHALL PROVIDE THE | | | ADDRESSES WITH AT LEAST 6" NUMBERS. | | | | | | 2) STANDPIPE SYSTEM SHALL BE | | | EQUIPPED WITH 2 1/2 TO 1 1/2 REDUCERS. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2003-12-11 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-12 |
Time |
14:13 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-12-11 |
Time |
14:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2003-09-04 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-09-04 |
Time |
16:48 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-09-04 |
Time |
16:48 |
Sent To |
|
|
| Notes |
| 2003-09-04 00:00:00 | APPROVED PROVISO: PLEASE SEE | | | COMMENTS AT 03040756. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2003-07-01 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-07-01 |
Time |
07:59 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-07-01 |
Time |
07:59 |
Sent To |
|
|
| Notes |
| 2003-07-01 00:00:00 | SEE NOTES FOR 03040754. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2003-05-09 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-05-09 |
Time |
15:22 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-05-09 |
Time |
15:22 |
Sent To |
|
|
| Notes |
| 2003-05-09 00:00:00 | 1) WET FIRE HYDRANTS ARE REQUIRED PRIOR | | | TO,DURING,AND AFTER CONSTRUCTION. | | | | | | 2) PLEASE PROVIDE AN OVERALL SITE PLAN | | | DISPLAYING ALL EXISTING BUILDINGS AND | | | CONDITIONS. | | | | | | 3) TAMPER SWITCHES,CHAINS AND LOCKS | | | ARE REQUIRED ON BACKFLOW DEVICE. | | | | | | 4) ALL GATE ENTRY SYSTEMS ARE TO BE | | | PROPERLY PERMITTED. | | | | | | 5) KNOX-BOX RAPID ENTRY SYSTEM ARE | | | REQUIRED FOR THE BUILDINGS. | | | | | | 6) BUILDING ADDRESSES REQUIRED. | | | | | | 7) PLEASE INDICATE INTERIOR FINISH | | | CLASSIFICATION INFORMATION FOR | | | WALLS AND CEILINGS OF CLUBHOUSE. | | | | | | 8) NFPA 13R NOTE DOES NOT APPLY. | | | | | | 9) THE STANDPIPE SYSTEM SHALL BE | | | EQUIPPED WITH 2 1/2 TO 1 1/2 REDUCERS. | | | | | | 10) TACTILE SIGNAGE REQUIRED AT | | | STAIRWAYS. | | | | | | 11) ALL SHAFTS THAT ARE LARGE ENOUGH | | | FOR PERSONS TO FALL INTO SHALL BE | | | MARKED SHAFTWAY. | | | | | | 12) PLEASE PROVIDE WRITTEN DOCUMENTATION | | | THAT EITHER BUILDING WILL NOT BE SOLD | | | INDEPENDENTLY FROM THE OTHER ONE SINCE | | | ONLY ONE FIRE PUMP IS SHOWN. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
32 |
Status |
N |
Date |
2005-02-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-02-09 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-02-09 |
Time |
14:14 |
Sent To |
B |
|
| Notes |
| 2005-02-09 00:00:00 | TO SHILL DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
31 |
Status |
N |
Date |
2004-08-26 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-26 |
Time |
15:11 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-26 |
Time |
15:11 |
Sent To |
P |
|
| Notes |
| 2004-08-26 00:00:00 | TO KS BOX/SUBMITTAL | | | PAN DRAIN DETAIL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
30 |
Status |
N |
Date |
2004-08-05 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-05 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-05 |
Time |
16:43 |
Sent To |
B |
|
| Notes |
| 2004-08-05 00:00:00 | TO SH DESK/SUBMITTAL | | | FIX FOR OPENING BIGGER THAN 12" | | | MAIL KIOSK & PICNIC PAVILLONQA |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
29 |
Status |
N |
Date |
2004-07-22 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-07-22 |
Time |
09:11 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-07-22 |
Time |
09:10 |
Sent To |
B |
|
| Notes |
| 2004-07-22 00:00:00 | TO SH DESK/SUBMITTAL | | | STUCCO OVERE BLOCK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
28 |
Status |
N |
Date |
2004-06-09 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-09 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-09 |
Time |
10:43 |
Sent To |
P |
|
| Notes |
| 2004-06-09 00:00:00 | TO KS BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
27 |
Status |
N |
Date |
2004-06-03 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-06-08 |
Time |
16:36 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-03 |
Time |
16:38 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
26 |
Status |
N |
Date |
2004-06-03 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-03 |
Time |
08:21 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-03 |
Time |
08:20 |
Sent To |
B |
|
| Notes |
| 2004-06-03 00:00:00 | TO SH DESK/ |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
25 |
Status |
N |
Date |
2004-05-12 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-12 |
Time |
14:24 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-12 |
Time |
14:24 |
Sent To |
B |
|
| Notes |
| 2004-05-12 00:00:00 | TO SH DESK/SUBMITTAL/TRUSS CUT OUT & | | | CONCRETE MASONRY UNIT |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
24 |
Status |
N |
Date |
2004-05-07 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-07 |
Time |
12:07 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-07 |
Time |
12:07 |
Sent To |
|
|
| Notes |
| 2004-05-07 00:00:00 | TO COMM BD#36 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
23 |
Status |
N |
Date |
2004-05-07 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-07 |
Time |
12:02 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-07 |
Time |
12:01 |
Sent To |
B |
|
| Notes |
| 2004-05-07 00:00:00 | TO SH DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
22 |
Status |
N |
Date |
2004-04-20 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-05 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-04-20 |
Time |
16:16 |
Sent To |
|
|
| Notes |
| 2004-04-20 00:00:00 | TO COMM BD#62 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
21 |
Status |
N |
Date |
2004-04-08 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-08 |
Time |
08:05 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-04-08 |
Time |
08:05 |
Sent To |
B |
|
| Notes |
| 2004-04-08 00:00:00 | TO SH DESK/4 SUBMITTALS/RINKER MASONARY | | | UNITS/DOOR SHOP DRAWS/CABINET SHOP DRAWS | | | BOND BEAM -5TH FLR #1 & 2 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
20 |
Status |
N |
Date |
2004-03-22 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-22 |
Time |
14:26 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-03-22 |
Time |
14:26 |
Sent To |
B |
|
| Notes |
| 2004-03-22 00:00:00 | TO SH DESK/SUBMITTALS/WEDGE ANCHORS FOR | | | STRUCTURAL STEEL COL & TPE N&S&M MORTAR | | | MIX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
19 |
Status |
N |
Date |
2004-03-19 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-19 |
Time |
16:15 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-03-19 |
Time |
16:15 |
Sent To |
B |
|
| Notes |
| 2004-03-19 00:00:00 | TO SH DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
18 |
Status |
N |
Date |
2004-02-25 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-25 |
Time |
14:51 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-25 |
Time |
14:51 |
Sent To |
B |
|
| Notes |
| 2004-02-25 00:00:00 | TO SH DESK/POWER FASTENERS SYSTEM FOR | | | DRILL & EPOXY\ BONSAL F-77 GROUT |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
17 |
Status |
N |
Date |
2004-02-09 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-09 |
Time |
16:30 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-09 |
Time |
16:30 |
Sent To |
B |
|
| Notes |
| 2004-02-09 00:00:00 | TO SH DESK/RAILING/SITE & POOL FENCE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
16 |
Status |
N |
Date |
2004-02-06 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-06 |
Time |
11:58 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-06 |
Time |
11:58 |
Sent To |
B |
|
| Notes |
| 2004-02-06 00:00:00 | TO SH DESK/SUBMITALL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
15 |
Status |
N |
Date |
2004-02-06 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-06 |
Time |
11:57 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-06 |
Time |
11:57 |
Sent To |
P |
|
| Notes |
| 2004-02-06 00:00:00 | TO KS BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
14 |
Status |
N |
Date |
2004-02-05 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-05 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-05 |
Time |
10:25 |
Sent To |
B |
|
| Notes |
| 2004-02-05 00:00:00 | TO SH DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2004-01-30 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-30 |
Time |
11:08 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-30 |
Time |
11:08 |
Sent To |
B |
|
| Notes |
| 2004-01-30 00:00:00 | TO SH DESK/SUBMITTAL/PAD ELEV SURVEY 1&2 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2004-01-27 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-27 |
Time |
12:24 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-27 |
Time |
12:24 |
Sent To |
B |
|
| Notes |
| 2004-01-27 00:00:00 | TO SH DESK/SUBMITTAL/FOOTINGS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2004-01-27 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-27 |
Time |
11:35 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-27 |
Time |
11:35 |
Sent To |
B |
|
| Notes |
| 2004-01-27 00:00:00 | TO SH DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2004-01-20 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-20 |
Time |
15:46 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-20 |
Time |
15:46 |
Sent To |
M |
|
| Notes |
| 2004-01-20 00:00:00 | TO PK BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2004-01-20 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-20 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-20 |
Time |
15:40 |
Sent To |
B |
|
| Notes |
| 2004-01-20 00:00:00 | TO SH DESK/SUBMITTAL/FILL CELLS & BEAMS | | | & CABINET SHOP DRAWING |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2004-01-08 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-08 |
Time |
16:47 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-08 |
Time |
16:47 |
Sent To |
|
|
| Notes |
| 2004-01-08 00:00:00 | TO DON NEELY |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2004-01-06 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-06 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-06 |
Time |
13:45 |
Sent To |
|
|
| Notes |
| 2004-01-06 00:00:00 | TO DON NEELY'S DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2003-12-12 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-12 |
Time |
14:26 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-12 |
Time |
14:26 |
Sent To |
B |
|
| Notes |
| 2003-12-12 00:00:00 | TO HP DESK/4 SUBMITTALS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2003-12-12 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-12 |
Time |
14:13 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-12 |
Time |
14:13 |
Sent To |
FIRE |
|
| Notes |
| 2003-12-12 00:00:00 | SUBMITTAL/SHOP DRAWINGS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-12-09 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-09 |
Time |
10:56 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-09 |
Time |
10:56 |
Sent To |
B |
|
| Notes |
| 2003-12-09 00:00:00 | TO HP DESK/SUBMITTALS/21 MISC SHOP | | | DRAWINGS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-11-10 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-05 |
Time |
14:17 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-11-10 |
Time |
16:25 |
Sent To |
|
|
| Notes |
| 2003-11-10 00:00:00 | TO COMM BD#41 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-06-05 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-05 |
Time |
10:29 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-06-05 |
Time |
10:29 |
Sent To |
|
|
| Notes |
| 2003-06-05 00:00:00 | COMM BOARD #39 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-04-11 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-11 |
Time |
10:08 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-04-11 |
Time |
10:08 |
Sent To |
|
|
| Notes |
| 2003-04-11 00:00:00 | COMM BOARD #43 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
P |
Date |
2004-05-11 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-05-11 |
Time |
07:17 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2004-05-11 |
Time |
07:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
F |
Date |
2004-04-24 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-04-24 |
Time |
08:24 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2004-04-24 |
Time |
08:00 |
Sent To |
|
|
| Notes |
| 2004-04-24 00:00:00 | DENIED: | | | PLAN SHEETS AP-M15.01 & M15.03, REMOVAL | | | OF LOUVERED DOOR.PLEASE INDICATE HOW | | | THIS COMPLIES WITH 2001 FBC(M) 502.1, | | | THE TOTAL OUTDOOR MAKE-UP AIR SHALL BE | | | EQUAL TO THAT REMOVED. | | | | | | AUXILIARY DRAIN PAN REQUIRED PER 2001 | | | FBC(M) 307.2.3 & 307.2.4. | | | | | | OTHER PLAN SHEETS ARE APPROVED. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
F |
Date |
2004-02-19 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-02-19 |
Time |
10:49 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2004-02-19 |
Time |
10:49 |
Sent To |
|
|
| Notes |
| 2004-02-19 00:00:00 | DENIED: | | | PLANS INDICATE THE REMOVAL OF THE | | | OUTSIDE AIR DUCT.PER 2001 FBC(M) | | | 403.3, THE ONLY BUILDINGS EXEMPT FROM | | | THE OUTSIDE AIR REQUIREMENTS ARE ONE | | | AND TWO FAMILY DWELLINGS.THIS PROJECT | | | IS MULTI-FAMILY THEREFOR OUTSIDE AIR IS | | | REQUIRED. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2004-01-28 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2004-01-28 |
Time |
19:07 |
Rev Time |
0.50 |
| Received By |
hmoser |
Date |
2004-01-28 |
Time |
19:06 |
Sent To |
|
|
| Notes |
| 2004-01-28 00:00:00 | SUBMITTALS OK |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2003-09-10 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-20 |
Time |
15:46 |
Rev Time |
1.50 |
| Received By |
hmoser |
Date |
2003-09-10 |
Time |
15:01 |
Sent To |
|
|
| Notes |
| 2003-09-10 00:00:00 | PASS/PRIVISO | | | 1) REFER TO SECTION 307.2.3 AUXILIARY | | | DRAIN PANS | | | 2) 4IN.CLEARANCE AROUND AIRHANDLERS | | | 3) NEED PROGRAMMABLE THERMOSTAT FOR | | | FINAL INSPECTION | | | PLAN REVIEW BY HAROLD MOSER | | | (561)805-6732 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2003-06-24 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-06-24 |
Time |
10:29 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2003-06-24 |
Time |
10:29 |
Sent To |
|
|
| Notes |
| 2003-06-24 00:00:00 | DENIED:BUILDING TYPE I | | | | | | PLAN SHEET M15.01, INDICATES EXHAUST | | | FROM ELEC METER RM HAS A FIRE DAMPER AT | | | THE OUTSIDE WALL.THE WALL SEPARATING | | | THE ELEC METER RM AND UNIT B2 HAS A FIRE | | | RESISTANCE RATING OF 1 HR.A FIRE | | | DAMPER IS REQUIRED AT THE PENETRATION | | | BETWEEN THE ELEC METER RM & UNIT B2. | | | | | | PLEASE CLARIFY VENTILATION REQUIREMENTS | | | FOR THE CORRIDORS AS PER 2001 FBC(M) | | | TABLE 403.3, PUBLIC SPACES - CORRIDORS | | | .05 CFM PER SQ FT. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2003-05-05 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-05-05 |
Time |
12:35 |
Rev Time |
4.00 |
| Received By |
pkrauss |
Date |
2003-05-05 |
Time |
11:17 |
Sent To |
|
|
| Notes |
| 2003-05-05 00:00:00 | DENIED: | | | APPARTMENTS | | | | | | 1.PLANS SHEET A15.01 ELEC METER RM, | | | AS PER 2001 FBC(M) 401.5.2, EXHAUST | | | OPENINGS SHALL BE LOCATED AS NOT TO | | | CREATE A NUISANCE.EXHAUST AIR SHALL | | | NOT BE DIRECTED ONTO WALKWAYS. | | | | | | 2.PLEASE INDICATE THE USE OF THE ROOMS | | | WHERE AHU-EL IS LOCATED. | | | | | | 3.CLARIFY EXTERIOR WALL - PLAN SHEET | | | M15.03, INDICATES AN EXHAUST TERMINATION | | | WITH A FIRE DAMPER.PLAN SHEET A1.04 | | | EXTERIOR WALL W1 INDICATES 1 HR, NO FIRE | | | DAMPERS INDICATED ON O.A. INTAKES. | | | | | | 4.PLAN SHEET M15.06 DETAIL OF THE | | | CONDENSATE TRAP CLARIFY VENT CAP IN OPEN | | | PLENUM. | | | | | | 5.PROVIDE OUTSIDE AIR CALCS AS PER | | | 2001 FBC(M) TABLE 403.3 | | | | | | CLUBHOUSE: | | | 1.PLAN SHEET CH M15.01 DRYER EXHAUST | | | PENETRATING RATED WALL AT FIRE PUMP RM, | | | THE IS NOT ACCEPTABLE.FIRE DAMPERS | | | CANNOT BE INSTALLED IN DRYER DUCT DUE | | | TO LINT BUILD-UP. | | | | | | 2.INDICATE WHAT TYPE OF DRYERS ARE TO | | | BE INSTALLED IN THE PUBLIC LAUNDRY ROOM. | | | (COMMERCIAL?) | | | | | | 3.PLEASE NOTE, SHOULD DRYERS IN THE | | | LAUNDRY ROOM EXHAUST GREATER THAN | | | 2,000 CFM, AIR MAKE UP IS REQUIRED. | | | | | | 4.PROVIDE OUTSIDE AIR CALCS AS PER | | | TABLE 403.3. | | | | | | 5.PLEASE CLARIFY THE MOP SINK IN THE | | | AHU CLOSET. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
12 |
Status |
F |
Date |
2004-12-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-12-23 |
Time |
04:21 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-12-23 |
Time |
04:21 |
Sent To |
|
|
| Notes |
| 2004-12-23 00:00:00 | DENIED | | | REFERENCE: FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | | | | 1) ENGINEERS SHALL LEGIBLY INDICATE | | | THEIR NAME AND LICENSE NUMBER AS WELL AS | | | THE NAME, ADDRESS, AND CERTIFICATE OF | | | AUTHORIZATION NUMBER OF THE ENGINEERING | | | BUSINESS ON EACH SHEET. FAC | | | 61G15-23.002(2) & FS 471.025. | | | | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
11 |
Status |
P |
Date |
2004-09-22 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-09-22 |
Time |
10:36 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-09-22 |
Time |
10:36 |
Sent To |
|
|
| Notes |
| 2004-09-22 00:00:00 | REVISION OK - NEW EMERGENCY PAN DRAIN | | | DETAIL FOR W/HEATER |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
10 |
Status |
P |
Date |
2004-06-18 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-06-18 |
Time |
09:00 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-06-18 |
Time |
09:00 |
Sent To |
|
|
| Notes |
| 2004-06-18 00:00:00 | REVISION OK - SHTS AP P14.05 & AP P14.07 | | | CHANGED PIPING TO 1/2" TO BATHROOMS KS |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
9 |
Status |
F |
Date |
2004-06-12 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-06-12 |
Time |
08:01 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2004-06-12 |
Time |
08:01 |
Sent To |
|
|
| Notes |
| 2004-06-12 00:00:00 | REVISION DENIED | | | | | | 1) IRRIGATION PLANS WERE NOT PART OF THE | | | ORIGINAL PLANS. SEPARATE PERMIT REQUIRED | | | FOR IRRIGATION. SUBMIT PLANS WITH PERMIT | | | APPLICATION. WATER USE PERMIT REQUIRED | | | FROM SOUTH FLORIDA WATER MANAGEMENT DIS- | | | TRICT PRIOR TO SUBMITTING FOR PERMIT | | | WITH CITY WPB. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
8 |
Status |
P |
Date |
2004-04-29 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-04-29 |
Time |
13:08 |
Rev Time |
1.25 |
| Received By |
kstevens |
Date |
2004-04-29 |
Time |
13:07 |
Sent To |
|
|
| Notes |
| 2004-04-29 00:00:00 | REVISION OK - SHTS P14.01 THRU P14.08 | | | W/.06A & .06B |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
7 |
Status |
P |
Date |
2004-02-09 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2004-02-09 |
Time |
10:45 |
Rev Time |
1.50 |
| Received By |
jleech |
Date |
2004-02-09 |
Time |
10:44 |
Sent To |
|
|
| Notes |
| 2004-02-09 00:00:00 | MATERIAL SUBMITALS PLUMBING OK |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
P |
Date |
2004-02-09 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-06 |
Time |
11:57 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2004-02-09 |
Time |
09:06 |
Sent To |
|
|
| Notes |
| 2004-02-09 00:00:00 | SUBMITAL DEMESTIC PUMPS ONLY OK |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
F |
Date |
2004-02-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-02-05 |
Time |
13:40 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2004-02-03 |
Time |
18:38 |
Sent To |
|
|
| Notes |
| 2004-02-05 00:00:00 | REVISIONDENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | 1) SHTS AP/P14.01 & AP/P14.03 CLEANOUTS | | | REQUIRED PER SECTIONS 708.3.1 & 708.3.3. | | | 2) SHT AP/P14.06 CLEANOUTS REQUIRED PER | | | SECTION 708.3.1 & 708.3.3. | | | 3) SHT AP/P14.08 DETAIL #3 SHOWS THE | | | DRAIN LINE FOR THE EMERGENCY SAFETY PAN | | | FOR THE WATER HEATER DELETED, AND THE | | | RELIEF LINE, (T&P), DRAINING OUTSIDE. | | | DETAIL #2 SHOWS T&P LINE DISCHARGING IN- | | | TO THE SAFETY PAN FOR THE WATER HEATER. | | | PLEASE CLAIRFY. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2003-12-09 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-12-09 |
Time |
12:49 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-12-09 |
Time |
12:49 |
Sent To |
|
|
| Notes |
| 2003-12-09 00:00:00 | REVISION OK - SHTS AP/P14.01, AP/P14.02, | | | AP/P14.03, AP/P14.07, AP/P14.08 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2003-09-04 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-09-04 |
Time |
15:48 |
Rev Time |
2.00 |
| Received By |
kstevens |
Date |
2003-09-04 |
Time |
15:47 |
Sent To |
|
|
| Notes |
| 2003-09-04 00:00:00 | PASSED/PROVISO | | | | | | BACKFLOW REQUIRED FOR TRASH CHUTE WASH |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2003-06-24 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-06-24 |
Time |
09:33 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2003-06-24 |
Time |
08:32 |
Sent To |
|
|
| Notes |
| 2003-06-24 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | 1) FROM PREVIOUS REVIEW. CLEANOUTS RE- | | | QUIRED IN BOTH BREEZWAYS, (STAIRWAYS), | | | SHTS P14.01 & P14.03. CLEANOUTS SHALL BE | | | FLOOR CLEANOUTS AS THEY ARE REQUIRED TO | | | BE TWO WAY CLEANOUTS, OR MORE CLEANOUTS | | | WILL BE REQUIRED AT THE UPSTREAM END OF | | | THE BLDG DRAIN. 708.5. CLEANOUTS ARE | | | REQUIRED TO BE ACCESSIBLE SO THEY SHALL | | | BE LOCATED OUTSIDE OF THE UNITS. 708.10 | | | 2) SHT P14.07 WATER RISER DIAGRAMS. IF | | | WATER HAMMER ARRESTORS ARE INSTALLED AT | | | THE WATER HEATERS THEY SHALL BE LOCATED | | | AS REQUIRED FOR ALL OTHER WATER HAMMER | | | ARRESTORS. PDI-WH 201 & MANUF. INSTALL. | | | INSTRUCTIONS. | | | 3) SUBMIT A HORIZONTAL SANITARY RISER | | | DIAGRAM. SHOW ALL RISER TIE-INS AND | | | SHOW DRAINAGE FIXTURE UNITS AS THEY | | | ACCUMULATE IN THE SYSTEM. 104.2.1 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-04-30 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-04-30 |
Time |
10:40 |
Rev Time |
3.00 |
| Received By |
kstevens |
Date |
2003-04-30 |
Time |
08:25 |
Sent To |
|
|
| Notes |
| 2003-04-30 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 11 | | | FHA-AMEND 98 DESIGN MANUAL | | | | | | 1) SHTS A5.05 & A5.06 LAVS SHALL BE 34" | | | MAX FROM FLOOR TO FLOOD RIM LEVEL. SEE | | | DETAIL PAGE 7.52 DESIGN MANUAL. | | | 2) ALL UNITS - PLEASE SPECIFY EITHER | | | SPECIFICATION "A" OR "B" BATHROOMS AS | | | REQUIRED BY DESIGN MANUAL REQUIREMENT | | | 7B PAGE 7.35 | | | 3) SEPARATE PERMIT REQUIRED FOR IRRIGA- | | | TION. | | | 4) SHT P14.01 CLEANOUTS REQUIRED IN BOTH | | | BREEZEWAYS. SECTION 708.3.1 (MAX. 100') | | | 5) SHT P14.06 RISERS S4 & S5, THE WASTE | | | STACH SHALL BE THE SAME SIZE THROUTHOUT | | | THE LENGTH OF THE WASTE STACK. SECTION | | | 910.4. | | | 6) SHT P14.07 WATER RISER DIAGRAMS, THE | | | WATER HAMMER ARRESTORS REQUIRED IN SECT. | | | 604.9, (ICE MAKER, DISHWASHER. WASH | | | MACHINE), SHALL BE LOCATED NEAR THE FIX- | | | TURES IN AN "EFFECTIVE RANGE" NOT IN THE | | | CEILING AS SHOWN. PDI-WH 201 & MANUF. | | | INSTALLATION INSTRUCTIONS. | | | 7) RPZ BACKFLOW REQUIRED FOR WATER | | | SERVICE AT EACH BLDG. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 | | | (561) 805-6721 | | | FAX (561) 653-2692 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2004-06-08 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-06-08 |
Time |
16:33 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-06-08 |
Time |
16:33 |
Sent To |
I |
|
| Notes |
| 2004-06-08 00:00:00 | REVISION APPROVED |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2003-09-12 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2003-09-12 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-09-12 00:00:00 | 9/12/03 OK PER GRACE MM |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2003-05-14 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-14 |
Time |
08:50 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-14 |
Time |
08:50 |
Sent To |
|
|
| Notes |
| 2003-05-14 00:00:00 | PROVIDE SITE PLAN FOR ZONING APPROVAL. |
|
|