| Plan Review Stops For Permit 03040745 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2003-08-06 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-08-06 |
Time |
09:28 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-08-06 |
Time |
09:28 |
Sent To |
Z |
|
| Notes |
| 2003-08-06 00:00:00 | PROVISO: | | | PROVIDE A SEPARATE PERMIT WITH THE | | | NECESSARY INFORMATION PRIOR TO | | | INSTALLATION OR CONSTRUCTION FOR: | | | | | | 1)THE METHOD OF PROTECTION FOR THE | | | LIGHT TRANSMITTING ROOF PANELS FOR | | | HURRICANE MISSLE IMPACT RESISTANCE. | | | | | | 2)NOTICE OF ACCEPTANCE AND OR TEST | | | REPORTS FOR THE DOORS AND WINDOWS ON | | | THE BUILDING. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2003-07-18 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-07-17 |
Time |
16:36 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-07-17 |
Time |
06:39 |
Sent To |
|
|
| Notes |
| 2003-07-17 00:00:00 | SHEET SPC 1, NOTE 13 SPECIAL | | | CONSTRUCTION DECLARE AN IMPORTANCE OF | | | FACTOR OF 1.0.THE USA METAL BUILDING | | | CALCULATIONS DATED 7/10/03 SHOW AN | | | IMPORTANCE FACTOR OF 0.70 BEING USED ON | | | PAGE 29.THIS IS NOT A CATEGORY I | | | BUILDING IT IS AT LEAST A CATEGORY II | | | (1.0 FACTOR) IF NOT A CATEGORY IV, | | | (1.15) BEING AN ANCILLARY BUILDING TO | | | AN ESSENTIAL FACILITY.PLEASE REVISE | | | THE CALCULATIONS AND DESIGN AS NECESSARY | | | | | | ALSO, THE 0.7 DECLARED DOES NOT AGREE | | | WITH THE 0.77 IN TABLE 6-1 OF ASCE 7-98. | | | | | | THE WAYNE DALTON DS-350 TEST REPORT, | | | SIGNED, SEALED AND DATED 10/10/2000 | | | DECLARES A DESIGN PRESSURE OF 31 PSF | | | FOR THE OVERHEAD DOORS.THIS IS LESS | | | THAN THE PRESSURES CONTAINED IN THE | | | ABOVE MENTIONED USA CALCULATIONS THAT | | | SHOW PRESSURES OF 38 AND 46 | | | RESPECTIVELY FOR ZONES 4 AND 5 EVEN | | | WHEN USING THE 30% REDUCTION. | | | | | | THE TEST REPORT DOES NOT INDICATE THE | | | TEST PERIOD OF 3600/V AS REQUIRED BY | | | FBC 1707.4.3. | | | | | | SHOW THE METHOD OF HURRICANE MISSILE | | | IMPACT RESISTANCE FOR THE GLAZED | | | SKYLIGHTS. SEE FBC 2604.1.2.1 AND FBC | | | 1606.1.4. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2003-06-20 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-06-20 |
Time |
15:45 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-06-19 |
Time |
11:47 |
Sent To |
|
|
| Notes |
| 2003-06-20 00:00:00 | THE AHRENS/UPHOFF PLAN SHEET 401 GRID | | | LINES DO NOT AGREE THE XUAN CHENG PAGE | | | TITLED "FOOTING PLAN" AND NEITHER OF | | | THOSE MATCH THE USA "ANCHOR BOLTPLAN. | | | | | | THE CHEN PLAN SHOWS FOUR COLUMNS AT | | | LINE4, THE USA AND UPHOFF PLANS THREE. | | | | | | WHO WILL BE ENGINEER OF RECORD? | | | ARCHITECT UPHOFF OR XUAN | | | CHEN, PE?PLEASE PROVIDE DESIGN | | | RESPONSIBILITY IN ACCORDANCE WITH FAC | | | 61G15-31. | | | | | | THE CALCULATIONS BY USA DATED 6/4/03 DO | | | NOT INVESTIGATE THE ROOF AND WALL | | | SHEETING AND THEIR CONNECTIONS. | | | | | | THE XUAN CHEN CALCULATIONS HAVE A USA | | | DESIGN DATA PAGE 4-64, THAT CITES THE | | | 1986 MBMA CODE FOR WIND DESIGN WHICH IS | | | NOT ACCEPTABLE FOR THE 2001 FBC. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-04-25 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-04-24 |
Time |
13:32 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-04-24 |
Time |
10:59 |
Sent To |
|
|
| Notes |
| 2003-04-24 00:00:00 | THE FOUNDATION PLAN ON SHEET 401 OF THE | | | AHREN'S PLANS DOES NOT AGREE WITH THE | | | ANCHOR BOLT PLACEMENT PLAN ON THEUSA | | | SHEET F1 OF 2.HAS THE ARCHITECT | | | REVIEWED THE USA PLAN? | | | | | | PROVIDE A CONSTRUCTION DETAIL FOR THE | | | ANCHOR BOLT PLATES TO BE LOCATED ON THE | | | 6' HIGH MASONRY WALL. | | | | | | PROVIDE COMPLETE STRUCTURAL | | | CALCULATIONS FOR THE FOUNDATION AND | | | MASONRY WALL SYSTEM. FBC 104.2 | | | | | | PROVIDE THE SPECIFICATIONFOR THE | | | REINFORCED MASONRY.SEE FBC 2103.1. | | | | | | THE USA CALCULATIONS DECLARE ALLOWABLE | | | DEFLECTIONS TO USA/MBMA STANDARDS. THE | | | CALCULATIONS MUST ALSO COMPLY WITH FBC | | | 1610. | | | | | | SEE ALSO FBC 1609 AND ALLOWABLE LOAD | | | REDUCTIONS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2003-06-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-06-24 |
Time |
10:35 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2003-06-24 |
Time |
10:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-04-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-04-23 |
Time |
16:02 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2003-04-23 |
Time |
16:02 |
Sent To |
|
|
| Notes |
| 2003-04-23 00:00:00 | *************** UNSAT ************* | | | | | | 1)NOTE: PLEASE SHOW ALL CONTINUOUS LOADS | | | AT 125%. 215-3/230-42 | | | | | | 2)NOTE: PLEASE SEE 225-31 FOR MEANS OF | | | DISCONNECTING FEEDERS COMING TO NEW | | | DETACHED BLDG. | | | | | | 3)NOTE: PLEASE SHOW LOAD ON EXISTING | | | PANEL THAT NEW FEED IS COMING FROM , TO | | | INCLUDE NEW LOAD.215-5 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2003-04-15 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2003-04-15 |
Time |
10:52 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2003-04-15 |
Time |
10:52 |
Sent To |
|
|
| Notes |
| 2003-04-15 00:00:00 | PASSED WITH PROVISOS: | | | 1. A RPZ BACKFLOW PREVENTER WILL NEED TO | | | BE INSTALLED IN WATER LINE TO THIS | | | FACILITY. | | | 2. A CLEAN OUT MUST BE INSTALLED IN | | | SANITARY SEWER LATERAL PRIOR TO | | | CONNECTING TO EXISTING MANHOLE. | | | 3. CONTACT RODNEY COMPO AT 837-4051 EXT. | | | 4074 FOR SAND/ OIL SEPARATOR REQUIREMENT | | | AND SIZE. | | | 4. ABOVE ITEMS MUST BE INSTALLED PER | | | PUBLIC UTILITIES ENGINEERING STANDARD | | | AND APPROVAL, 659-8040. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2003-06-30 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-06-30 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-06-30 |
Time |
14:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2003-04-24 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-04-24 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-04-24 |
Time |
09:51 |
Sent To |
|
|
| Notes |
| 2003-04-24 00:00:00 | 1) PLEASE PROVIDE INFORMATION ON WHAT | | | BE STORED IN THIS BUILDING. | | | | | | 2) WILL THERE BE ANY FLAMMABLE OR | | | COMBUSTIBLE LIQUIDS OR SOLIDS STORED IF | | | SO HOW MUCH. | | | | | | 3) THIS INFORMATION IS NEEDED TO | | | DETERMINE THE CLASSIFICATION OF HAZARD. | | | | | | NATE MCCRAY, CAPTAIN | | | 659-8096, EXT 8497 | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-06-09 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-09 |
Time |
09:15 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-06-09 |
Time |
09:15 |
Sent To |
|
|
| Notes |
| 2003-06-09 00:00:00 | COMM BOARD #40 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-04-10 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-10 |
Time |
14:24 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-04-10 |
Time |
14:24 |
Sent To |
|
|
| Notes |
| 2003-04-10 00:00:00 | COMM BOARD #49 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2003-04-26 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2003-04-26 |
Time |
11:59 |
Rev Time |
0.25 |
| Received By |
hmoser |
Date |
2003-04-26 |
Time |
11:59 |
Sent To |
|
|
| Notes |
| 2003-04-26 00:00:00 | NO MECHANICAL PLANS. | | | MECHANICAL CONTRACTOR MUST SUBMIT PLANS | | | WITH PERMIT APPLICATION | | | PLAN REVIEW BY HAROLD MOSER | | | (561)805-6732 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2003-06-30 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-06-30 |
Time |
16:38 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-06-30 |
Time |
16:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-04-26 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-04-26 |
Time |
10:38 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2003-04-26 |
Time |
10:47 |
Sent To |
|
|
| Notes |
| 2003-04-26 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 ADMIN. CODE, CHAPTER | | | ONE & AMENDS. | | | | | | 1) SHT 101 WATER SERVICE, PVC SHALL NOT | | | BE USED PER TABLE 605.5 | | | 2) SHT 301 MINIMUM FACILITIES, PER TABLE | | | 403.1 A W/C, LAV, DRINKING FOUNTAIN, AND | | | A SERVICE SINK ARE REQUIRED. | | | 3) SHT 501 PLEASE CONTACT RODNEY COMPO, | | | ENVIRONMENTAL COMPLIANCE, INDUSTRIAL | | | PRETREATMENT FOR SIZE OF SAND INTERCEP- | | | TOR. WASTE ORD. #2938-96. (561) 837-4074 | | | 4) SHT 501 PER 104.3.1.1 A SANITARY | | | RISER DIAGRAM IS REQUIRED. | | | 5) SHT 501 THE 3" VENT SHALL CONNECT | | | ABOVE THE CENTER LINE OF THE HORIZONTAL | | | DRAIN PIPE. SECTION 905.3 | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 | | | (561) 805-6721 | | | FAX (561) 653-2692 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-08-06 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-08-06 |
Time |
09:40 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-08-06 00:00:00 | 8/6/03 PASS OK PER SHIRLEY MM |
|
|