Plan Review Details - Permit 03040734
Plan Review Stops For Permit 03040734
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2003-09-03 Cont ID  
Sent By sthyng Date 2003-09-03 Time 16:02 Rev Time 1.00
Received By sthyng Date 2003-09-03 Time 16:02 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2003-07-30 Cont ID  
Sent By csiegber Date 2003-09-03 Time 14:57 Rev Time 1.00
Received By sthyng Date 2003-07-30 Time 10:57 Sent To  
Notes
2003-07-30 00:00:00******CORRECTIONS******
  
 1.)THE AREA CALCULATIONS STATE THAT
 THE ADDITIONAL LIVING SPACE IS 356
 SQUARE FEET, BUT THE IMPACT FEE STAMP
 AND THE ENERGY CALC IS FOR 264 SQUARE
 FEET.ALL THREE SHOULD BE CONSISTENT.
 PLEASE CLARIFY.
  
 2.)STUCCO OVER WIRE LATH IS REQUIRED
 TO BE 3 COAT (7/8"); FBC2504.2.2,
 ASTM C1063.
  
 3.)SIGN THE OWNER/AGENT LINE OF THE
 ENERGY CALC.
  
 4.)SEE PREVIOUS CORRECTION LIST, ITEM
 #2; IMPACT PROTECTION REQUIRED FOR
 GLAZING FBC10606.1.4.HOW WILL SHUTTERS
 BE INSTALLED IN THE METAL FRAME WALL?
 PROVIDE A DETAIL AND A HURRICANE SHUTTER
 ATTACHMENT SCHEDULE, SEE ATTACHED.
  
 5.)SEE THE PREVIOUS CORRECTION LIST,
 ITEM 3.THE WINDOW PRODUCT APPROVAL
 IS ACCEPTABLE BUT THERE WAS ONLY ONE
 COPY SUBMITTED.THE DOCUMENTATION
 SUBMITTED FOR THE SLIDING GLASS DOOR
 IS TO RENEW A PRODUCT APPROVAL.THE
 ACTUAL PRODUCT APPROVAL WAS NOT
 PROVIDED.PRODUCT APPROVALS FOR THE
 IMPACT PROTECTION WERE NOT SUBMITTED.
 CURRENT PRODUCT APPROVALS ARE AVAILABLE
 AT WWW.MIAMIDADE.GOV (FIND A DEPT, BLDG
 CODE COMPLIANCE, PRODUCT CONTROL, SEARCH
 APPROVED PRODUCTS).
  
 6.)PROVIDE WIND DESIGN INFORMATION,
 FBC1606.1.7.
  
 7.)THE SEAL MUST BE DATED FAC61G15-23.
 002(1).SEE ATTACHED.
  
 8.)IF THE ENGINEER MAKES CHANGES TO
 THE SEALED PLAN, HAVE THE CHANGES
 INITIALED AND DATED.
  
 9.)SUBMIT BOTH COPIES OF THE 1ST
 SUBMITTAL WITH THE APPROVED ELECTRIC
 DRAWING.IF BOTH ARE NOT SUBMITTED,
 THE PLANS WILL REQUIRE AN ELECTRIC
 REVIEW WITH THE NEXT RESUB.
  
 SAMANTHA THYNG, BUILDING PLANS EXAMINER
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-05-08 Cont ID  
Sent By btrobaug Date 2003-05-08 Time 13:42 Rev Time 1.50
Received By sthyng Date 2003-05-05 Time 21:22 Sent To  
Notes
2003-05-05 00:00:00**********CORRECTIONS************
  
 1.)BEFORE A PERMIT TO CONSTRUCT MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 2.)HURRICANE PROTECTION REQUIRED
 FBC 1606.1.4.
  
 3.)SUBMIT TWO COPIES OF PRODUCT
 APPROVALS FOR THE WINDOW, SLIDING GLASS
 DOOR, AND HURRICANE PROTECTION.
  
 4.)ENERGY CALCS REQUIRED FBC13-101.2.
  
 5.)FBC 104.2.1, NAME AND SIGNATURE OF
 THE PERSON RESPONSIBLE FOR THE DESIGN
 SHALL BE ON THE DRAWINGS.
  
 6.)PROVIDE AREA CALCULATIONS.
  
 7.)THE RIGHT ELEVATION APPEARS TO
 EXCEED THE 20% OF OPENINGS ALLOWED BY
 FBC TABLE 600.PLEASE ADDRESS.
  
 8.) FIREBLOCK REQUIRED FBC 705.3.
  
 9.)FBC 104.2, ALL DRAWINGS TO BEAR
 THE NAME AND SIGNATURE OF THE PERSON
 RESPONSIBLE FOR THE DESIGN.
  
 10.)PROVIDE INFORMATION IN REGARDS TO
 MATERIAL TO BE USED FOR EXTERIOR WALLS.
 HOW DOES THIS DESIGN MEET THE
 REQUIREMENTS OF CHAPTER 16?IF
 NECESSARY, GET A STRUCTURAL ENGINEER TO
 CERTIFY THE DESIGN.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 SAMANTHA THYNG, BUILDING PLANS EXAMINER
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-05-08 Cont ID  
Sent By sthyng Date 2003-07-30 Time 10:58 Rev Time 0.50
Received By btrobaug Date 2003-05-08 Time 13:14 Sent To B
Notes
2003-05-08 00:00:00NOTE!!
 AN ELECTRICAL PERMIT IS REQUIRED FOR
 THIS PROJECT.PLEASE APPLY FOR SAME PRIOR
 TO DOING ANY ELECTRICAL WORK,PER 104.1.1
 FBC.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-09-03 Cont ID  
Sent By csiegber Date 2003-09-03 Time 14:57 Rev Time 0.00
Received By csiegber Date 2003-09-03 Time 14:57 Sent To B
Notes
2003-09-03 00:00:00TO ST DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-07-30 Cont ID  
Sent By sthyng Date 2003-07-30 Time 11:07 Rev Time 0.00
Received By sthyng Date 2003-07-30 Time 11:07 Sent To B
Notes
2003-07-30 00:00:00TO ST DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-04-30 Cont ID  
Sent By shernand Date 2003-04-30 Time 13:14 Rev Time 0.00
Received By shernand Date 2003-04-30 Time 13:14 Sent To B
Notes
2003-04-30 00:00:00MISC BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-04-09 Cont ID  
Sent By shernand Date 2003-04-09 Time 15:49 Rev Time 0.00
Received By shernand Date 2003-04-09 Time 15:49 Sent To Z
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-05-05 Cont ID  
Sent By shernand Date 2003-04-09 Time 15:49 Rev Time 0.00
Received By sgraham Date   Time   Sent To B
Notes
2003-04-10 00:00:00DENIED, NEED SURVEY