| Plan Review Stops For Permit 03040477 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
9 |
Status |
P |
Date |
2004-03-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-03-05 |
Time |
14:33 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-03-05 |
Time |
14:33 |
Sent To |
|
|
| Notes |
| 2004-03-05 00:00:00 | REVISION, 1A6.2.1 2/13/4 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
P |
Date |
2004-03-01 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-02-28 |
Time |
16:52 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2004-02-28 |
Time |
16:52 |
Sent To |
|
|
| Notes |
| 2004-02-28 00:00:00 | TRUSS SUBMITTALS, OK PER HP (RESOLVED | | | ISSUES ON TELEPHONE) |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
F |
Date |
2004-01-28 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-25 |
Time |
12:21 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2004-01-28 00:00:00 | TRUSS ENGINEERING PREPARED BY THOMAS | | | KELAHER, PE. DATED VARIOUSLY 11/25/03 | | | AND 12/12/03. | | | | | | THE REVIEW OF DELEGATED ENGINEERING | | | SHOULD BE BY THE ENGINEER OF RECORD, | | | NOT AN EIT. | | | | | | SHEETS DATED 12/12/03 LABELED SHOP | | | DRAWING SK-01 AND OTHERS LABELED RT-01, | | | H-02, ETC., SIGNED AND SEALED BY T. | | | KELAHER DO NOT SHOW ANY LOADING OR | | | CRITERIA USED FOR THE DESIGN. | | | | | | THE COMPUTER CALCULATIONS PROVIDED ARE | | | NOT REFERENCED OR RECOGNIZED IN THE | | | KELAHER COVER LETTER.THE COVER LETTER | | | "METAL STUD ROOF FRAMING | | | SPECIFICATIONS" DOES NOT REFENCE OR | | | INDEX ANY OF THE OTHER TRUSS DESIGN | | | INFORMATION. | | | | | | PLEASE REVISE AS NECESSARY. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2003-10-23 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-27 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-10-23 |
Time |
07:54 |
Sent To |
|
|
| Notes |
| 2003-10-23 00:00:00 | REVISONS DATED 9/2/03 AND 9/23/03 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2003-08-14 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-21 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-08-14 |
Time |
09:58 |
Sent To |
FIRE |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
N |
Date |
2003-08-01 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-08-05 |
Time |
13:10 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-08-01 00:00:00 | STH LETTER DATED 7/31/03 RE: FILLED | | | MASONRY. | | | | | | THE ARCHITECT CITES FBC 709.3.2 AS A | | | METHOD FOR CODE COMPLIANCE.THIS IS | | | NOT VALID FOR THE CORE FILL 500 SINCE | | | THE TEST STANDARDS ARE FOR MINERAL TYPE | | | AGGREGATES AND THE FOAM BASED MATERIAL | | | DOES NOT LEND ITSELF TO THOSE METHODS. | | | | | | BASED ON THE INFORMAION PROVIDED, | | | PARTICULARLY THE SOUTHWEST RESEARCH | | | INSTITUTE, DATA, IT MAY BE APPROVED FOR | | | USE UNDER FBC 103.7 ALTERNATE MATERIALS | | | AND METHODS. | | | | | | THERE ARE SOME CONFLICTS IN THE | | | INFORMATION THAT MUST BE RESOLVED | | | BEFORE THE BUILDING OFFICIAL MAY RENDER | | | A DECISION TO ACCEPT THIS MATERIAL/METHO | | | | | | PAGE 30F5 IN REPORT 01-6740-711 DATED | | | 8/95 STATED THAT TEST ASSEMBLY HAD | | | CELLS FILLED WITH MORTAR AS SHOWN IN | | | FIGURE A-3 OF APPENDIX A.THIS APPENDIX | | | AND FIGURE ARE NOT INCLUDED AND APPEAR | | | TO BE A KEY ELEMENT IN THE TEST WHEN | | | TAKEN IN THE CONTEXT OF THE | | | INTRODUCTION TO THE REPORT. | | | | | | THE SWRI LETTER TO JACK TEMPLE DATED | | | 11/4/96 REFERENCES AN SWRI FINAL REPORT | | | 01-7522-607 WHICH IS DIFFERENT THAN THE | | | 01-6740-711 PROVIDED. | | | | | | PLEASE REVIEW FBC 103.7 AND PROVIDE | | | COMPLETE AND COMPLEMENTARY DATA SO THAT | | | EQUIVALENT CODE COMPLIANCE MAY BE | | | DETERMINED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2003-07-16 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-07-16 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-07-16 |
Time |
14:52 |
Sent To |
|
|
| Notes |
| 2003-07-16 00:00:00 | THE STH LETTER DATED 6/24/03 RESPONDED | | | TO THE REQUEST FOR INFORMATION AND/OR | | | CODE DEFICIENCIES CONTAINED IN THE | | | 5/28/03 COMMENT LIST. | | | | | | THE THRESHOLD INSPECTION PLAN HAS BEEN | | | RECEIVED, HOWEVER THE STATEMENT | | | REQUIRED BY FS 553 TO APPEAR ON THE | | | PLANS HAS NOT.THE ARCHITECT'S | | | RESPONSE TO SEE THE ENCLOSED LETTER | | | FROM ONMJ IS NOT SUFFICIENT, NOR WAS AN | | | LETTER FOUND.PLEASE REVISE THE PLANS | | | AS NECESSARY. | | | | | | THE REQUEST FOR THE LISTING OF THE | | | RINKER T-14 BLOCK MEETING A THREE HOUR | | | RATING WAS RESPONDED TO WITH A UL | | | LISTING U905. RINKER WAS NOT FOUND AS | | | AN "ELIGIBLE MANUFACTURER" AS CALLED FOR | | | IN ITEM #1 OF THAT LISTING.PLEASE | | | PROVIDE DATA DEMONSTRATING COMPLIANCE | | | WITH FBC 701.5. | | | | | | THE HUSTON SEATING PLAN DATED 6/13/03 | | | DOES NOT APPEAR TO HAVE THE 19" CLEAR | | | SPACE BETWEEN THE CHAIR AND TABLE IN | | | ACCORDANCE WITH FBC 1019.10.3.5.1 FOR | | | LECTURE ROOMS 1, 2 AND 3. | | | | | | THE EMERGENCY LIGHING REQUIRED BY FBC | | | 1016.2 IS NOT SHOWN ON THE PLANS.A | | | SEPARATE RESPONSE BY THE ELECTRICAL | | | ENGINEER AS NOTED IN THE ARCHITECT'S | | | RESPONSE, HAS NOT BEEN FOUND.PLEASE | | | REVISE AS NECESSARY. | | | | | | PANIC HARDWARE IS REQUIRED IN | | | CLASSROOMS 1, 2 AND 3 AS DEPICTED ON | | | SHEET A1.3.2 SINCE THE OCCUPANT LOAD IS | | | > 100.SEE FBC 1021.3.1. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2003-05-28 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-05-28 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-05-21 |
Time |
13:25 |
Sent To |
|
|
| Notes |
| 2003-05-28 00:00:00 | PLANS DATED 5/3/03 NO REVISION DATE. | | | | | | PLEASE PROVIDE A RECENT PROPERTY SURVEY. | | | | | | THIS IS A THRESHOLD BUILDING AS DEFINED | | | IN 553.71, FLORIDA STATUTES AND REQUIRES | | | A THRESHOLD INSPECTION PLAN AND THE | | | STATEMENT ON THE PLANS DECLARING | | | COMPLIANCE WITH 553. | | | | | | PLEASE PROVIDE A LISTING OR | | | SPECIFICATION THAT A RINKER T-14 BLOCK | | | MEETS A THREE HOUR FIRE RATING WITH AN | | | EQUIVALENT THICKNESS REQUIRED BY FBC | | | 709.3. | | | | | | SHEET A1.3.1, NOTE #1 ERRONEOUSLY | | | DECLARES "UNLIMITED, UNPROTECTED | | | OPENINGS FOR WALLS MORE THAN 15' ..." | | | SEE FBC TABLE 600, FBC 705 SPEAKS TO | | | FIRE PROTECTION OF OPENINGS, NOT AREA. | | | PLEASE REVISE AS NECESSARY. | | | | | | SHEETS A1.3.1 AND 1.3.2.SHOW A | | | SEATING PLAN AND AISLE WIDTHS.SEE FBC | | | 1003.1.2. | | | | | | SHEET A1.3.3, ROOM 307.THE | | | MEASUREMENTOF THE DIAGONAL DISTANCE | | | SEPARATION OF THE EXIT ACCESS DOORS IS | | | INCORRECT AS SHOWN ON THE PLAN.A | | | STRAIGHT LINE DISTANCE IS USED. SEE FBC | | | 1004.1.4 AND REVISE AS NECESSARY. | | | | | | SHEET A1.4.1 INCORRECTLY CALCULATES THE | | | RATIO OF WALL OPENINGS TO WALL AREA. | | | THE WALL AREA FOR TABLE 600 IS BASED ON | | | A PER FLOOR AREA, AND AS MEASURED FROM | | | FLOOR TO CEILING NEXT ABOVE.OPENINGS | | | ARE TAKEN AS THE ROUGH OPENING SIZE. | | | PLEASE REVISE AS NECESSARY. | | | | | | WHAT IS THE GATE AND HAND RAIL SHOWN IN | | | SECTION 1 SHEET A5.2.1 USED FOR? | | | | | | SHEET A5.2.2 THE DELEGATION OF THE | | | DESIGN OF THE STAIRS REQUIRES SPECIFIC | | | INFORMATION NOT A CODE SECTION | | | REFERENCE.SEE FBC 104.2. | | | | | | SHEET A6.1.1 HAS REFERENCE TO A GLAZING | | | SCHEDULE AND SPECIFICATIONS NOT PROVIDED | | | WITH THIS PERMIT APPLICATION. | | | | | | SHEET A6.2.1 SHOWS A SCREEN IN THE IN | | | THE EMERGENCY OVERFLOW SCUPPER PIPE. | | | WHATVOLUME OF WATER IS CALCULATED TO | | | FLOW THROUGH THIS SCREEN AT WHAT RATES? | | | SEE FBC 1503.4. | | | | | | SHEET A6.2.2, SECTION 6.SHOW A | | | CONSTRUCTION DETAIL FOR THE SUSPENDED | | | PLASTER SOFIT INCLUDING FRAMING AND | | | FASTENERS. SEE FBC 104.2. | | | | | | SHEET A7.2.1 CALLS FOR THE UNDERCUTTING | | | OF FIRE RATED DOORS.SEE NFPA 80 FOR | | | LIMITATIONS. | | | | | | SHEET S1 SHOWS COLUMN FOOTINGS EXTENDING | | | BEYOND THE APPARENT PROPERTY LINE. | | | SEE FBC 3207. | | | | | | SHEET S6 CITES SSTD 12-97.SSTD 12-99 | | | IS INVOKED BY THE FBC, PLEASE REVISE | | | AND INSURE COMPLIANCE AS NECESSARY. | | | | | | SHEET S4, SHOW THE METHOD OF FIRE | | | PROTECTION FOR THE COLUMNS SHOWN AS SC2. | | | AND THE STEEL COLUMNS SHOWN IN SECTION | | | 3/6.1.2. | | | | | | SHEET S7, SHOW THE FIRE PROTECION FOR | | | THE STRUCTURE SHOWN IN SECTION AS | | | TYPICAL HANGING PARTITION DETAIL. | | | | | | SHOW HOW COMPLIANCE WITH FBC 1405 WILL | | | BE ACCOMPLISHED, (FIRE DEPARTMENT | | | ACCESS), WITH REGARDS TO THE HURRICANE | | | MISSILE IMPACT GLAZING.SEE FBC 903.5 | | | #2 FOR PERSPECTIVE. | | | | | | SHOW THE PANIC HARDWARE FOR THE DOORS IN | | | ACCORDANCE WITH FBC 1021.3.1. | | | | | | SHOW THE STAIR IDENTIFICATION AS | | | PROVIDED FOR IN FBC 1016.4. | | | | | | SHOW THE EMERGENCY LIGHTING FOR THE | | | COVERED WALKWAYS ON THE SOUTH AND WEST | | | SIDES OF THE FIRST FLOOR. SEE FBC 1016.2 | | | | | | BEFORE A PERMIT TO CONSTRUCT MAY BE | | | ISSUED IMPACT FEES MUST BE PAID TO THE | | | COUNTY, THE PERMIT PLANS STAMPED BY | | | THAT OFFIEC AND A COPY OF THE PAID | | | RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION.CALL 561-233-5025 FOR | | | MORE INFORMATION. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-01-21 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-19 |
Time |
14:04 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-04-22 |
Time |
10:11 |
Sent To |
|
|
| Notes |
| 2003-04-23 00:00:00 | PAID PLAN REVIEW NOT A PERMIT | | | APPLICATION. | | | | | | THE PLANS PROVIDED WERE INCOMPLETE AND | | | WITHOUT SPECIFICATIONS SO A CLOSE AND | | | CRITICAL PLAN REVIEW WAS NOT POSSIBLE. | | | | | | AT TIME OF PERMIT APPLICATION ADHERENCE | | | TO THE ITEMS IN FBC 104.3.1.1 WILL | | | ENSURE AN EXPEDITIOUS PLAN REVUE. | | | | | | THE PROPOSED BUILDING WILL BE A | | | THRESHOLD BUILDING AND MUST COMPLY WITH | | | FBC 105.13. | | | | | | SHEET A2.5.1, ROOF PLAN.THE AREA | | | DECLARED AS "UOCCUPIED SPACE" WILL BE | | | COUNTED AS A STORY SINCE IT DOES NOT | | | COMPLY WITH FBC 1511.1.1.3, FURTHER THE | | | TOTAL AREA OF ROOF STRUCTURES EXCEEDS | | | THE 1/3 ALLOTTED BY FBC 1511.1.1.2. | | | (THIS INCLUDES THE MANSARD LIKE | | | STRUCTURES) | | | | | | CONSEQUENTLY, THE PROPOSED BUILDING | | | WILL EXCEED THE ALLOWABLE HEIGHT OF 65' | | | IN TABLE 500 FOR TYPE IV 1 HOUR | | | PROTECTED CONSTRUTION. PLEASE REVISE AS | | | NECESSARY PRIOR TO PERMIT APPLICATION. | | | | | | SHEET S6 THE MASONRY COLUMN SCHEDULE | | | INDICATES 6 #7'S IN AN 8X16 BLOCK. | | | WHAT IS THE ANTICIPATED CLEAR CELL | | | SPACE FOR GROUT? |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
12 |
Status |
P |
Date |
2004-06-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-06-25 |
Time |
13:28 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2004-06-25 |
Time |
13:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
11 |
Status |
F |
Date |
2004-06-23 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-25 |
Time |
12:26 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-06-23 |
Time |
14:14 |
Sent To |
|
|
| Notes |
| 2004-06-23 00:00:00 | ******** UNSAT ****** | | | | | | 1)NOTE: PLEASE REVISED TITLE BLOCK | | | WITH CORRECT CA#. | | | FAC 61G15-23.002/ FS 471.023 | | | | | | 2)NOTE: PLEASE SEE THAT ALL THREE SETS | | | MUST BE SIGNED, DATED AND SEALED. | | | ONE SET MISSING. | | | THIS JOB REQUIRES THREE SETS FOR THRES- | | | -HOLD JOB. | | | FAC 61G15-23.002 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
10 |
Status |
P |
Date |
2004-05-21 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-18 |
Time |
16:28 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2004-05-21 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2004-05-21 00:00:00 | REVISED CHILLER RISER DIAGRAM. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
9 |
Status |
P |
Date |
2004-04-03 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-18 |
Time |
15:14 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-04-03 |
Time |
11:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
8 |
Status |
P |
Date |
2004-03-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-03-08 |
Time |
16:35 |
Rev Time |
1.50 |
| Received By |
dpalmer |
Date |
2004-03-08 |
Time |
16:35 |
Sent To |
FIRE |
|
| Notes |
| 2004-03-08 00:00:00 | FIRE ALARM OK IN MOVR INTO FRON ENTRANCE | | | COLUMN. OK PER MIKE C. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
F |
Date |
2004-03-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-03-08 |
Time |
12:10 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-03-08 |
Time |
11:39 |
Sent To |
|
|
| Notes |
| 2004-03-08 00:00:00 | ******** UNSAT *************** | | | | | | 1)NOTE: PLEASE SEE SHEET E3.4 THIS SHEET | | | IS REQUIRED TO BE SIGNED BY THE ENGINEER | | | OF RECORD. THIS HAS BEEN NOTED AND | | | REQUESTED ON PREVIOUS REVIEWS. | | | FS 471.025 | | | PLEASE PROVIDE ONE NEW SET AS ONE SET | | | IS BEING RETAINED FOR ABOVE COMMENT FOR | | | FILE. | | | | | | PLEASE SUBMIT THE ABOVE FOR REVIEW, IF | | | THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
F |
Date |
2004-02-24 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-02 |
Time |
09:50 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-02-24 |
Time |
16:03 |
Sent To |
FIRE |
|
| Notes |
| 2004-02-24 00:00:00 | ************** UNSAT ********** | | | | | | 1)NOTE: PLEASE HAVE ALL SHEETS SIGNED | | | DATED AND SEALED. PLEASE SEE SOME | | | SHEETS ARE INITIALED. | | | FS 471.025 | | | | | | 2)NOTE: PLEASE SUBMIT LIGHTNING PROTECT- | | | -ION SYSTEM UNDER SEPARATE ELECTRICAL | | | PERMIT APPLICATION. | | | | | | INSTALLATION TO ALSO MEET NFPA-780. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2003-08-18 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-20 |
Time |
16:07 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2003-08-18 |
Time |
10:44 |
Sent To |
|
|
| Notes |
| 2003-08-18 00:00:00 | STAMPED ELECTRICAL SHEETS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2003-08-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-08-12 |
Time |
06:29 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2003-08-12 |
Time |
14:21 |
Sent To |
|
|
| Notes |
| 2003-08-12 00:00:00 | ************ UNSAT *************** | | | | | | 1)NOTE: PLEASE SEE E,3.3,3.4,6.1 ARE | | | MISSING BEING SIGNED, DATED AND SEALED | | | BY ENGINEER. | | | CALLED JEFF SOBLE, WAITING FOR NEW | | | SHEETS BEFORE STAMPING ELECTRICAL. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2003-07-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-07-17 |
Time |
11:37 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2003-07-17 |
Time |
11:37 |
Sent To |
|
|
| Notes |
| 2003-07-17 00:00:00 | ************* UNSAT **************** | | | | | | 1)NOTE: RESPOND LETTER DATED 6/26/03 | | | FROM BRICE BLDG, MENTIONS TO SEE SHEET | | | AC-8 AND 9 FOR CONTROL VOLTAGE BUT NO | | | RESPONSE OR CORRECTIONS WERE MADE FOR | | | MEANS OF DISC OF WIRING COMING INTO BLDG | | | FROM ANOTHER SERVICE. 225-31,230-2 ETC | | | SIGNAGE 230-2 | | | | | | 2)NOTE: PLEASE SEE BLDG REVIEW COMMENTS | | | FOR ELECTRICAL FIXTURES MISSING. | | | PLEASE SEE THAT THIS WILL HAVE A DIRECT | | | AFFECT ON ELECTRICAL PLANS AND WILL | | | NEED TO BE REVISED FOR ELECTRICAL AND | | | FIRE REVIEW. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2003-05-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-05-19 |
Time |
19:20 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2003-05-19 |
Time |
19:20 |
Sent To |
|
|
| Notes |
| 2003-05-19 00:00:00 | ************** UNSAT ********** | | | | | | 1)NOTE: PLEASE CLARIFY CONTROL VOLTAGE | | | OF CHILLER PLANT CONTROL WIRING? | | | PLEASE CLARIFY MEANS OF DISC IN MAIN | | | ELECTRICAL ROOM FOR ALL CONTROL WIRING | | | FEEDING ANOTHER BLDG FROM A SEPARATE | | | SERVICE? 225-31 | | | ALL DISC SHALL HAVE SIGNAGE AS REQ`D PER | | | NEC. 230-2 | | | | | | 2)NOTE: PLEASE SEE 384-16 FOR MAIN | | | REQ`D ON SECONDARY SIDE OF TRANSFORMER | | | FOR PANEL "4LA". | | | | | | 3)NOTE: PLEASE SHOW ALL CONTINUOUS LOADS | | | AT 125%. 230-42,215-3 ETC. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-04-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-04-15 |
Time |
14:15 |
Rev Time |
1.50 |
| Received By |
dpalmer |
Date |
2003-04-15 |
Time |
13:56 |
Sent To |
|
|
| Notes |
| 2003-04-15 00:00:00 | ************* UNSAT **************** | | | | | | 1)NOTE: PLEASE SUBMIT COMPLETED PLANS | | | FOR REVIEW. PLEASE SEE BLANK PANEL | | | SCHEDULES, NO CIRCUITING, LOAD CALCS | | | ETC ETC. | | | | | | PLEASE NOTE, PLANS MAY HAVE ADDITIONAL | | | COMMENTS ONCE COMPLETED AND SUBMITTED | | | FOR REVIEW. | | | PLEASE SUBMIT THE ABOVE FOR REVIEW. | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 | | | [email protected] |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
4 |
Status |
P |
Date |
2003-07-23 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2003-07-23 |
Time |
11:46 |
Rev Time |
0.50 |
| Received By |
mamini |
Date |
2003-07-23 |
Time |
11:45 |
Sent To |
|
|
| Notes |
| 2003-07-23 00:00:00 | PASSED: | | | 1. SEE PERMIT # 03071236 FOR UNDERGROUND | | | UTILITIES AND SITE WORK. | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
F |
Date |
2003-07-03 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-07-09 |
Time |
16:55 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2003-07-03 |
Time |
09:22 |
Sent To |
|
|
| Notes |
| 2003-07-03 00:00:00 | FAILED: | | | 1. PLEASE NOTE THAT A SEPARATE PERMIT | | | APPLICATION AND FEES FOR UNDERGROUND | | | UTILITIES AND SITE WORK IS REQUIRED. | | | PLEASE SUBMIT TWO SETS CIVIL PLANS ONLY | | | (SIGNED & SEALED).PLANS MUST BE | | | APPROVED BY PUBLIC UTILITIES PRIOR TO | | | ISSUANCE OF UNDERGROUND UTILITIES AND | | | SITE WORK PERMIT BY BUILDING DEPARTMENT. | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
F |
Date |
2003-05-15 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2003-05-15 |
Time |
08:53 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2003-05-15 |
Time |
08:47 |
Sent To |
|
|
| Notes |
| 2003-05-15 00:00:00 | FAILED: | | | 1. PLEASE NOTE THAT A SEPARATE PERMIT | | | APPLICATION AND FEES FOR UNDERGROUND | | | UTILITIES AND SITE WORK WILL BE REQUIRED | | | 2. A SEPARATE BACKFLOW PREVENTER IN | | | 2 1/2" WATER SERVICE TO THE BUILDING IS | | | REQUIRED. | | | 3. IS THERE ANY EXSITING DDCV ON 8" FIRE | | | LINE ON SITE?, IF SO PLEASE SHOW. | | | 4. BROKEN/ DAMAGED SIDEWALK, CURB & | | | GUTTERS AT ALL SIDE OF PROPERTY MUST BE | | | RESTORED/REPALCED. | | | 5. CIVIL /SITE PLANS MUST BE APPROVED | | | BY PUBLIC UTILITIES PRIOR TO ISSUANCE OF | | | CIVIL/SITE PERMIT BY BUILDING DEPARTMENT | | | 6. ANY CONSTRUCTION IN DIXIE HWY WILL | | | REQUIRE A SEPARATE PERMIT FROM FDOT. | | | 7. PLEASE PROVIDE EASEMENT FOR FOOTING, | | | AREAL ENCROACHMENT INTO THE PUBLIC ROW | | | TO PUBLIC UTILITIES, ATT: VINCE NOEL, | | | 659-8040 EXT. 8440 | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2003-04-16 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2003-04-16 |
Time |
13:57 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2003-04-16 |
Time |
13:57 |
Sent To |
|
|
| Notes |
| 2003-04-16 00:00:00 | FAILED : | | | 1. PLEASE PROVIDE CIVIL/SITE PLAN FOR | | | OUR REVIEW AND APPROVAL.PLAN SHOULD | | | INCLUDE PERVIOUS AND IMPERVIOUS CALC. | | | FOR THE ENTIRE SITE DUE TO THE PROPOSED | | | STRUCTURE, THE DRAINAGE FOR THE SITE, | | | POLLUTION PREVENTION PLANS AND | | | CONNECTION TO THE SERVICES. | | | 2. PLEASE SUBMIT TWO SETS OF CIVIL PLANS | | | TO PUBLIC UTILITIES FOR THIER REVIEW AND | | | APPROVAL, 659-8040. | | | 3. PLEASE NOTE THAT A SEPARATE PERMIT | | | APPLICATION AND FEES FOR UNDERGROUND | | | UTILITIES AND SITE WORK WILL BE REQUIRED | | | | | | IF ANY QUESTION PLEASE CONTACT 659-8086 | | | EXT. 8492 MOHAMMAD R. AMINI |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2004-03-09 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2004-03-09 |
Time |
11:13 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2004-03-09 |
Time |
11:13 |
Sent To |
|
|
| Notes |
| 2004-03-09 00:00:00 | REVISION DATED FOR 2-18-04 & 3-08-04 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2003-08-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-03-08 |
Time |
16:36 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-08-19 |
Time |
15:17 |
Sent To |
|
|
| Notes |
| 2003-08-19 00:00:00 | ***********PROVISO********************** | | | A LETTER FROM JEFF SOBLE INDICATING THAT | | | COMMENTS DATED JUNE 13, 2003,(NOTES 1 | | | THRU 3) BE ADDRESSED. PER ASST. FIRE | | | MARSHAL MIKE CARSILLO. | | | | | | NATE MCCRAY, CAPTAIN | | | 805-6722 OR 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2003-06-13 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-08-14 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-06-13 |
Time |
09:05 |
Sent To |
|
|
| Notes |
| 2003-06-13 00:00:00 | 1) COULD NOT LOCATE INTERIOR FINISH | | | CLASSIFCATION FOR WALLS AND CEILINGS. | | | | | | 2) NOTE ON DOOR SCHEDULE STILL INDICATES | | | UNDERCUTTING FIRE RATED DOORS. PLEASE | | | EXPLAIN. | | | | | | 3) WHY IS THE EXHAUST DUCT FOR HOOD 1 | | | AND HOOD 2 NOT ENCLOSED IN A RATED | | | SHAFT. | | | | | | 4) WHERE IS THE FDC. PLEASE SHOW ITS | | | RELATIONSHIP TO A FIRE HYDRANT WITHIN | | | 150 FEET. | | | | | | 5) NO EXIT SIGNS SHOWN ON ELECTRICAL | | | DRAWINGS NEAR LECTURE HALL DOORS | | | WITHIN PARTITIONS. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2003-04-11 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-05-28 |
Time |
13:00 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-04-11 |
Time |
09:12 |
Sent To |
|
|
| Notes |
| 2003-04-11 00:00:00 | 1) BUILDING LOCATED IN CITY FIRE LIMITS. | | | CERTAIN RESTRICTIONS APPLY. | | | | | | 2) A KNOX-BOX IS REQUIRED. | | | | | | 3) PANIC HARDWARE REQUIRED ON EXIT DOORS | | | WITH OCCUPANT LOADS OF 100 OR MORE | | | PERSONS. | | | | | | 4) TACTILE SIGNAGE REQUIRED AT STAIRWELL | | | DOORS. | | | | | | 5) ALL SHAFTWAYS THAT PERSONS CAN FALL | | | INTO MUST BE MARKED "SHAFTWAY" IN | | | RED LETTERS. | | | | | | 6) PLEASE PROVIDE FLAMESPREAD CRITERIA | | | ON MOVABLE PARTITIONS IN LECTURE HALLS. | | | | | | 7) PLEASE SHOW EXISTING AND OR NEW FIRE | | | HYDRANTS ON SITE PLAN. | | | | | | 8) PLEASE EXPLAIN GATES IN STAIRTOWERS. | | | | | | 9) PLEASE PROVIDE FLAMSPREAD DETAILS | | | ON MOVABLE PARTITIONS FOR CLASSROOMS | | | 1&2. | | | | | | 10) WHAT WILL THE UNFINISHED EXPANSION | | | AREA BE USED FOR. | | | | | | 11) BUILDING ADDRESS REQUIRED ON | | | PROPER ELEVATION. MINIMUM 6" NUMBERS | | | REQUIRED. | | | | | | 12) PLEASE INDICATE HANDICAPPED SEATING. | | | | | | 13) ELEVATOR REQUIRED TO BE STRETCHER | | | ACCESSIBLE. | | | | | | 14) PLEASE EXPLAIN UNOCCUPIED SPACE | | | ON ROOF PLAN. | | | | | | 15) PLEASE EXPLAIN 8" HIGH CONCRETE STEP | | | | | | 16) PLEASE PROVIDE FLAMSPREAD DETAILS | | | ON ACOUSTICAL PANELS. | | | | | | 17) NO HANDRAILS SHOWN AT 8" STEP. | | | | | | 18) PLEASE PROVIDE PRESCRIPTIVE | | | STRENGTH REQUIREMENTS FOR HANDRAILS. | | | | | | 19) EXIT SIGNS NOT SHOWN AT MOVEABLE | | | PARTION WALL LOCATIONS. | | | | | | 20) NO EXIT MARKINGS IN CLASSROOMS. | | | | | | 21) NO EXIT MARKINGS IN DRUG INFORMATION | | | CENTER. | | | | | | 22) DUCT SMOKE DETECTORS ARE TO ACTIVATE | | | THE FIRE ALARM SYSTEM. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
21 |
Status |
N |
Date |
2004-06-25 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-25 |
Time |
12:26 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-25 |
Time |
12:26 |
Sent To |
E |
|
| Notes |
| 2004-06-25 00:00:00 | TO DP DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
20 |
Status |
N |
Date |
2004-06-18 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-18 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-18 |
Time |
16:28 |
Sent To |
E |
|
| Notes |
| 2004-06-18 00:00:00 | TO DP DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
19 |
Status |
N |
Date |
2004-05-18 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-18 |
Time |
15:14 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-18 |
Time |
15:14 |
Sent To |
E |
|
| Notes |
| 2004-05-18 00:00:00 | TO DP DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
18 |
Status |
N |
Date |
2004-03-02 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-02 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-03-02 |
Time |
09:50 |
Sent To |
E |
|
| Notes |
| 2004-03-02 00:00:00 | TO DP DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
17 |
Status |
N |
Date |
2004-02-25 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-25 |
Time |
12:21 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-25 |
Time |
12:21 |
Sent To |
B |
|
| Notes |
| 2004-02-25 00:00:00 | TO SH/HP DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
16 |
Status |
N |
Date |
2004-02-20 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-20 |
Time |
16:07 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-20 |
Time |
16:07 |
Sent To |
E |
|
| Notes |
| 2004-02-20 00:00:00 | TO DP DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
15 |
Status |
N |
Date |
2004-02-12 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-12 |
Time |
10:18 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-12 |
Time |
10:18 |
Sent To |
B |
|
| Notes |
| 2004-02-12 00:00:00 | TO SH DESK/SUBMITTALS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
14 |
Status |
N |
Date |
2004-01-27 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-27 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-27 |
Time |
14:53 |
Sent To |
B |
|
| Notes |
| 2004-01-27 00:00:00 | TO HP DESK/SUBMITTALS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2003-10-21 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-21 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-21 |
Time |
14:46 |
Sent To |
B |
|
| Notes |
| 2003-10-21 00:00:00 | TO HP DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2003-10-09 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-09 |
Time |
10:07 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-09 |
Time |
10:06 |
Sent To |
B |
|
| Notes |
| 2003-10-09 00:00:00 | TO HP DESK/SCAFFOLD & SHORING |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2003-10-02 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-02 |
Time |
11:33 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-02 |
Time |
11:33 |
Sent To |
B |
|
| Notes |
| 2003-10-02 00:00:00 | TO HP DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2003-09-12 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-12 |
Time |
11:50 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-09-12 |
Time |
11:50 |
Sent To |
B |
|
| Notes |
| 2003-09-12 00:00:00 | TO HP DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2003-09-03 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-03 |
Time |
16:42 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-09-03 |
Time |
16:41 |
Sent To |
B |
|
| Notes |
| 2003-09-03 00:00:00 | TO HP DESK | | | TO HP DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2003-08-05 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-08-05 |
Time |
13:10 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2003-08-05 |
Time |
13:09 |
Sent To |
B |
|
| Notes |
| 2003-08-05 00:00:00 | TO H.P. DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2003-07-31 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-07-31 |
Time |
13:15 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2003-07-31 |
Time |
13:14 |
Sent To |
|
|
| Notes |
| 2003-07-31 00:00:00 | TO COMM BD #59 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2003-07-09 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-07-09 |
Time |
16:55 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-07-09 |
Time |
16:55 |
Sent To |
ENG |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2003-06-27 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-27 |
Time |
11:35 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-06-27 |
Time |
11:35 |
Sent To |
|
|
| Notes |
| 2003-06-27 00:00:00 | COMM BOARD #38 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-05-19 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-19 |
Time |
14:04 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-19 |
Time |
14:04 |
Sent To |
B |
|
| Notes |
| 2003-05-19 00:00:00 | HP DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-05-15 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-15 |
Time |
16:53 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-15 |
Time |
16:53 |
Sent To |
|
|
| Notes |
| 2003-05-15 00:00:00 | ADDED TO BOX #37, SUBMITTAL OF 3 SOIL | | | TESTING PLANS. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-05-15 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-14 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-14 |
Time |
16:52 |
Sent To |
|
|
| Notes |
| 2003-05-14 00:00:00 | COMM BOARD #37 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-04-07 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-07 |
Time |
09:44 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-04-07 |
Time |
09:44 |
Sent To |
|
|
| Notes |
| 2003-04-07 00:00:00 | COMM BOARD #13 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2003-07-08 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-07-08 |
Time |
06:54 |
Rev Time |
0.50 |
| Received By |
pkrauss |
Date |
2003-07-08 |
Time |
06:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2003-05-23 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-05-23 |
Time |
14:13 |
Rev Time |
1.20 |
| Received By |
pkrauss |
Date |
2003-05-23 |
Time |
14:12 |
Sent To |
|
|
| Notes |
| 2003-05-23 00:00:00 | DENIED: | | | | | | THE FOLLOWING ITEMS NOT ADDRESSED FROM | | | PREVIOUS REVIEW DATED 4-30-03. | | | ITEM # | | | 2.PLAN SHEET AC-2 STORAGE RM 117, | | | EXHAUST TERMINATES OVER THE DOOR.2001 | | | FBC(M) 401.5.2 EXHAUST SHALL NOT BE | | | DIRECTED ONTO WALKWAYS.FRESH AIR | | | INTAKE SHALL BE A MINIMUM OF 10 FT FROM | | | EXHAUST AS PER 2001 FBC(M) 401.5.1. | | | ITEM # | | | 3. PLAN SHEET AC-7 WAS REVISED TO SHOW | | | RESTROOM EXHAUST RISER IN A RATED SHAFT. | | | DUCTWORK FROM HOOD THAT ALSO PENTRATES | | | THROUGH MORE THAN ONE FLOOR SHALL ALSO | | | BE IN FIRE RATED SHAFT. 2001 FBC(M) | | | 607.4. SEE ALSO 510.6.1. | | | ITEM # | | | 5.PLEASE REFER TO 2001 FBC(M) 510 FOR | | | HAZARDOUS EXHAUST SYSTEMS CONCERNING THE | | | THE FUME HOODS EXHAUST AND MAKE-UP AIR. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2003-05-03 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-04-30 |
Time |
15:56 |
Rev Time |
3.00 |
| Received By |
pkrauss |
Date |
2003-04-30 |
Time |
15:28 |
Sent To |
|
|
| Notes |
| 2003-04-30 00:00:00 | DENIED: | | | | | | 1.AS PER F.S. 471.025, ALL DRAWINGS, | | | SPECIFICATION AND PLANS SHALL BE HAVE | | | AN IMPRESSION-TYPE SEAL AND BE SIGNED, | | | SEALED, AND DATED. | | | | | | 2.PLAN SHEET AC-2 STORAGE RM 117, | | | EXHAUST TERMINATES OVER THE DOOR.2001 | | | FBC(M) 401.5.2 EXHAUST SHALL NOT BE | | | DIRECTED ONTO WALKWAYS.FRESH AIR | | | INTAKE SHALL BE A MINIMUM OF 10 FT FROM | | | EXHAUST AS PER 2001 FBC(M) 401.5.1. | | | | | | 3.PLAN SHEET AC-7 DETAIL FOR THE | | | RESTROOM EXHAUST RISER, AS PER 2001 | | | FBC(M) 607.4, DUCTS EXTENDING THROUGH | | | MORE THAN ONE FLOOR SHALL BE PROTECTED | | | BY A SHAFT ENCLOSURE.BUILDINGS LESS | | | THAN 4 STORIES IN HEIGHT, ENCLOSURE | | | SHALL HAVE A FIRE RESISTANCE RATING OF | | | NOT LESS THAN 1 HR.BUILDINGS GREATER | | | THAN 4 STORIES IN HEIGHT, ENCLOSURE | | | SHALL BE NOT LESS THAN 2 HR RATING. | | | THE ABOVE SHALL BE FOR ALL DUCTS | | | PENETRATING MORE THAN ONE FLOOR. | | | | | | 4.PLEASE CLARIFY MAKE-UP AIR FOR THE | | | FUME HOODS.AIR BALANCE SCHEDULE | | | INDICATES "N/A".MANUFACTURERS SPECS | | | IN THE ACCESSORIES SHOWS A AUXILLARY | | | AIR PLENUM KIT.WILL THIS BE UTILIZED? | | | | | | 5.PLEASE REFER TO 2001 FBC(M) 510 FOR | | | HAZARDOUS EXHAUST SYSTEMS CONCERNING THE | | | FUME HOODS EXHAUST AND MAKE-UP AIR. | | | | | | 6.PLEASE PROVIDE ENERGY CALCS. | | | | | | 7.NO COMBUSTIBLES ABOVE THE CEILING IN | | | THE RETURN AIR PLENUM. 2001 FBC(M) | | | 602.2.1. | | | | | | 8.SEE PLUMBING COMMENT #10 ON | | | CONDENSATE. | | | | | | 9.SEE FIRE DEPARMENT COMMENT #22 DUCT | | | SMOKE DETECTORS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2003-07-28 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-07-28 |
Time |
13:41 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2003-07-28 |
Time |
13:41 |
Sent To |
|
|
| Notes |
| 2003-07-28 00:00:00 | PASSED/PROVISO | | | | | | SHT P6.1 VALVE REQUIRED FOR HOT DOWN- | | | FEED LINE. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2003-06-11 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-06-11 |
Time |
11:26 |
Rev Time |
2.50 |
| Received By |
kstevens |
Date |
2003-06-11 |
Time |
11:26 |
Sent To |
|
|
| Notes |
| 2003-06-11 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 11 | | | | | | 1) SHTS P2.1 & P5.1 CLEANOUTS REQUIRED | | | BY SECTION 708.3.3 REQUIRED. PLEASE SHOW | | | ON FLAT LAYOUT AND SANT. RISER DIAGRAM. | | | "CLEANOUTS SHALL BE INSTALLED AT EACH | | | CHANGE OF DIRECTION OF THE BIILDING | | | DRAIN OR HORIZONTAL WASTE OF SOIL LINES | | | GREATER THAN 45 DEGREES. WHERE MORE THAN | | | ONE CHANGEOF DIRECTION OCCURS IN A RUN | | | OF PIPING, ONLY ONE CLEANOUT SHALL BE | | | REQUIRED FOR EACH 40 FEET OF DEVELOPED | | | LENGTH OF THE DRAINAGE PIPING." | | | 2) SHT P5.2 A RELIEF VENT IS REQUIRED AS | | | THE CONDENSATE DRAIN EXITS THE BLDG. IN | | | CASE OF BACKUP IN THE STORM SYSTEM, | | | (CATCH BASIN), THE RELIEF VENT SHALL | | | KEEP THE STORM WATER FROM BACKING UP IN- | | | TO THE BLDG. | | | 3) SHT P6.1 FULL OPEN VALVES REQUIRED AT | | | THE BASE OF EACH RISER. SEC 606.1(3). | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 | | | (561) 805-6721 | | | FAX (561) 653-2692 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-04-14 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-04-14 |
Time |
16:34 |
Rev Time |
5.00 |
| Received By |
kstevens |
Date |
2003-04-14 |
Time |
16:33 |
Sent To |
|
|
| Notes |
| 2003-04-14 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 11 | | | | | | 1) SHTS A2.1.1, A2.2.1, A2.3.1, & A2.4.1 | | | PLEASE PROVIDE CALCULATIONS FOR MINIMUM | | | FACILITIES PER BLDG CODE TABLE 1003.1 & | | | PLUMBING CODE TABLE 403.1. | | | 2) SHTS A2.2.1 & A4.2.1, STUDENT LOUNGE | | | ROOM #206 SHALL COMPLY WITH SEC. 11-4.24 | | | DETAIL #1, PLEASE SHOW COMPLIANCE WITH | | | SECTION 11-4.24 AND ALL SUBSECTIONS. | | | 3) PLEASE SUBMIT RISER DIAGRAMS FOR DWV, | | | STORM, ACID WASTE, AND WATER. PLEASE | | | SHOW ALL PIPE SIZES, TYPE OF MATERIAL. | | | SHOW DFU'S AS THEY ACCUMULATE IN SANIT- | | | ARY SYSTEM. SHOW SQUARE FEET AS THEY | | | ACCUMULATE IN THE STORM SYSTEM. SHOW | | | WATER HAMMER ARRESTORS REQUIRED IN SEC. | | | 604.9 LOCATED NEAR THE FIXTURES IN AN | | | "EFFECTIVE RANGE" NOT AT THE TOP OF THE | | | DROPS IN THE CEILING. PDI-WH 201, AND | | | MANUF. INSTALLATION INSTRUCTIONS. | | | 4) SHT A2.2.1 PLEASE PROVIDE MANUF. INFO | | | FOR DISTILLED WATER SYSTEM. | | | 5) SHTS A2.3.1, A2.4.1, A4.2.1 DETAIL | | | #5, SINKS SHALL COMPLY WITH 11-4.24 AND | | | ALL SUBSECTIONS. PLEASE SHOW ON DETAIL | | | AND SUBMIT DETAIL FOR FACULITY LOUNGE ON | | | 4TH FLOOR. | | | 6) SHT A4.1.1 DETAIL #1, PLEASE SHOW | | | CLEAR FLOOR SPACE FOR ALL HDCP FIXTURES. | | | SHOW 5' TURNING CIRCLE FOR TOILET ROOMS. | | | 7) SHT A4.1.1 HDCP DETAILS, W/C TO BE | | | 18" OFF WALL TO CENTER OF FIXTURE. SHOW | | | ON DETAIL. - NOTE #12 DRAIN TO BE INSUL- | | | ATED ALSO. | | | 8) SHT P0.1 WATER HEATER DETAIL #4, | | | THERMAL EXPANSION CONTROL REQUIRED. SEC. | | | 607.3.2- DIELECTRIC UNIONS NOT APPROV- | | | ED FOR USE IN WATER SYSTEM. PLEASE DE- | | | LETE REFERENCE. | | | 9) SHT PO.1 DILUTION TANK FOR ACID WASTE | | | SYSTEM SHALL BE SIZED BY RODNEY COMPO, | | | ENVIRONMENTAL COMPLIANCE. (561) 837-4074 | | | WASTE ORD: 2938-96 | | | 10) SHT P0.1 DETAIL #1, CONDENSATE TRAP, | | | VENT LINE WITH PERFORATED CAP SHALL NOT | | | TERMINATE IN A/C ROOM IF ROOM IS USED AS | | | A PLENUM. VENT THRU ROOF REQUIRED. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 | | | (561) 805-6721 | | | FAX (561) 653-2692 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2003-08-20 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2003-08-20 |
Time |
15:45 |
Rev Time |
0.25 |
| Received By |
mmclean |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-08-20 00:00:00 | 8/20/03 PASS PER ANGELLA JONES-VANN MM |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2003-05-23 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2003-04-15 |
Time |
15:19 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-05-23 00:00:00 | NEED CITY COMMISSION APPROVAL | | 2003-04-15 00:00:00 | DENIED,SAFE SITE TRIANGLE ISSUES | | | CALL RANDALL GRANBERRY AT 659-3031 |
|
|