| Plan Review Stops For Permit 03040476 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2003-04-23 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-04-23 |
Time |
16:19 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-04-23 |
Time |
16:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2003-05-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-05-21 |
Time |
16:15 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2003-05-21 |
Time |
16:15 |
Sent To |
|
|
| Notes |
| 2003-05-21 00:00:00 | NOTES REDLINED |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-04-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-04-15 |
Time |
06:36 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-04-15 |
Time |
06:36 |
Sent To |
|
|
| Notes |
| 2003-04-15 00:00:00 | ************** UNSAT ******** | | | | | | 1)NOTE: PLEASE SEE 250-24/ AN EQUIPMENT | | | GROUNDING CONDUCTOR IS SHOWN ON RISER | | | AND FROM METER TO MAIN BRK PANEL. | | | AN EQUIPMENT GRND IS ONLY INSTALLED | | | AFTER THE FIRST MEANS OF DISCONNECT. | | | | | | 2)NOTE: PLEASE SEE 600-5 FOR MISSING | | | REQ`D SIGN CIRCUIT. | | | | | | 3)NOTE: PLEASE SEE 210-62 FOR MISSING | | | SHOW WINDOW RECEPTS REQ`D. SHOWN ON | | | LOAD CALCS. | | | 4)NOTE: PLEASE SEE 700-12E FOR CIRCUIT- | | | -ING OF EXT/EM LTS. ON SAME BRANCH | | | CIRCUIT AS GEN LT IN SAME AREAS. | | | | | | 5)NOTE: PLEASE CORRELATE PANEL SCHEDULE | | | AND LOAD CALCULATIONS. WATER HEATER | | | SHOWN AS 3500W ON PANEL AND 3000W ON | | | LOAD CALCS? | | | | | | 6)NOTE; PLEASE SHOW ALL CONTINUOUS LOADS | | | AT 125%. 215-3/230-42 ETC. | | | | | | 7)NOTE: PLEASE SHOW/CLARIFY HOW FEED | | | IS GETTING FROM METER TO PANEL. AS PER | | | LOCAL AMENDMENTS, NO MORE THAN 8' OF | | | UNPROTECTED CONDUCTORS INSIDETHE BLDG. | | | 230-70 | | | A MAIN DISC/OCP MAY BE REQ`D OUTSIDE | | | OR PANEL LOCATION MAY NEED TO BE MOVED? | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2003-05-28 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-05-28 |
Time |
10:28 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-05-28 |
Time |
10:28 |
Sent To |
|
|
| Notes |
| 2003-05-28 00:00:00 | PASSED ON 4-25-03 BY MIKE CARSILLO | | | | | | NATE MCCRAY, CAPTAIN | | | 805-6722 OR 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2003-04-25 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-04-25 |
Time |
12:02 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-04-25 |
Time |
12:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-05-21 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-21 |
Time |
15:04 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-21 |
Time |
15:04 |
Sent To |
|
|
| Notes |
| 2003-05-21 00:00:00 | COMM BOARD #31, RESTAMPED PLANS. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-04-04 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-04 |
Time |
16:15 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-04-04 |
Time |
15:56 |
Sent To |
|
|
| Notes |
| 2003-04-04 00:00:00 | COMM BOARD #36 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2003-04-28 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-04-28 |
Time |
14:08 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2003-04-28 |
Time |
13:28 |
Sent To |
|
|
| Notes |
| 2003-04-28 00:00:00 | NO MECHANICAL PLANS SUBMITTED FOR REVIEW | | | | | | PLEASE PROVIDE PLANS, AND OUTSIDE AIR | | | CALCULATIONS IN ACCORDANCE WITH 2001 | | | FBC(M) TABLE 403.3. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2003-05-29 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-05-29 |
Time |
17:11 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-05-29 |
Time |
17:11 |
Sent To |
|
|
| Notes |
| 2003-05-29 00:00:00 | PASSED PROVISO - 607.3.2 THERMAL EXPAN- | | | SION REQUIRED - 909.1 ONLY FIXTURES FROM | | | THE BATHROOM GROUP SHALL BE WET VENTED - | | | WATER COOLER SHALL BE ARI-1010 COMPLIANT | | | 410.1 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-04-22 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-04-22 |
Time |
10:48 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-04-22 |
Time |
10:48 |
Sent To |
|
|
| Notes |
| 2003-04-22 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 11 | | | | | | 1) A DRINKING FOUNTAIN IS REQUIRED AND | | | A SERVICE SINK IS REQUIRED PER TABLE | | | 403.1. (ALSO SEE SECTION 410.1) | | | 2) PLUMBING RISER SHOWS THREE SINKS, BUT | | | FLOOR PLAN SHOW TWO SINKS. PLEASE | | | CLAIRFY. | | | 3) PLEASE SUBMIT A WATER RISER DIAGRAM. | | | 4) RPZ BACKFLOW REQUIRED ON WATER SERV. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 | | | (561) 805-6721 | | | FAX (561) 653-2692 |
|
|