| Plan Review Stops For Permit 03040146 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
N |
Date |
2003-10-22 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-10-22 |
Time |
13:17 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-10-22 |
Time |
13:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
N |
Date |
2003-08-29 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-08-29 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-08-29 |
Time |
14:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2003-11-12 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-11-12 |
Time |
17:20 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2003-11-12 |
Time |
16:54 |
Sent To |
FIRE |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2003-09-26 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-12 |
Time |
14:29 |
Rev Time |
2.00 |
| Received By |
dpalmer |
Date |
2003-09-26 |
Time |
13:48 |
Sent To |
|
|
| Notes |
| 2003-09-26 00:00:00 | *********** UNSAT ***************** | | | | | | 1)NOTE: PLEASE SEE NOTES FROM PREVIOUS | | | REVIEW. PLEASE CORRELATE RISER WITH | | | PANELS. PLEASE SEE THAT NOW MORE LOADS | | | HAVE BEEN ADDED TO PANEL SCHEDULE WITH | | | LESS LOAD? PLEASE SEE THAT THIS IS NOW | | | DUE TO PANEL VOLTAGE BEING SHOWN AT 277/ | | | 480V??? PLEASE SEE RISER, PANEL IS SHOWN | | | AT 120/208V?? PLEASE CORRELATE AND | | | RECONFIGURE LOAD CALCAULTIONS. | | | 215.5 | | | | | | 2)NOTE: PLEASE SEE WRONG NEC CODE REF. | | | PLANS REF CODE FROM 1996 NEC?? 250-94 | | | PLEASE SEE AND REF 250.66 FROM THE 99 | | | NEC FOR | | | | | | 3)NOTE: PLEASE SEE THAT TRANSFORMERS | | | ARE STILL NOT SHOWN BEING GROUNDED PER | | | 250.30 RISER SHOWS NONE AND DETAIL SHOWS | | | ?? | | | | | | 4)NOTE: PLEASE TAKE OUTALL OLD/VOIDED | | | SHEETS AND INSERT NEW SHEETS INTO TWO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW.IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | PLEASE SEE COPY OF FS 553.80(2)(B) | | | WITH RESPECT TO DESIGN PROFESSIONAL. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2003-08-26 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-23 |
Time |
16:18 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2003-08-26 |
Time |
19:11 |
Sent To |
|
|
| Notes |
| 2003-08-26 00:00:00 | ********* UNSAT ************ | | | | | | 1)NOTE: PLEASE SEE NOTES FROM PREVIOUS | | | TWO REVIEWS. PLEASE SEE NEW PANEL IN | | | KIOSK DOES NOT SHOW ANY FEEDS OR BRANCH | | | CIRCUITING FOR GATE POWER. | | | PLEASE CLARIFY WHERE POWER IS COMING | | | FROM FOR GATES? SEE FIRE REVIEW NOTES. | | | | | | 2)NOTE: PLEASE CLARIFY GROUNDING FOR | | | TRANSFORMER PER 250.30 | | | | | | PLEASE SEE ZONING NOTES FOR KIOSK TO BE | | | UNDER SEPARATE PERMIT.. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | GATES AND SUBMIT BLDG UNDER SEPARATE | | | PERMIT WITH PLANS. IF THERE ARE ANY | | | QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2003-04-17 |
|
|
Cont ID |
|
| Sent By |
dbaxter |
Date |
2003-08-20 |
Time |
16:13 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-04-17 |
Time |
09:11 |
Sent To |
|
|
| Notes |
| 2003-04-17 00:00:00 | *********** NO WIRING DIAGRAM/HOOK-UP | | | SUBMITTED. | | | | | | ELECTRICAL INSPECTOR TO FIELD VERIFY. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-04-08 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-16 |
Time |
10:41 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2003-04-08 |
Time |
15:54 |
Sent To |
B |
|
| Notes |
| 2003-04-08 00:00:00 | ************** UNSAT *************** | | | | | | 1)NOTE: PLEASE SUBMIT ELECTRICAL PLAN | | | FOR HOOK UP AND LOCATION OF FEED. | | | | | | 2)NOTE: PLEASE SUBMIT SPECS ON GATE | | | MOTOR(S). | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2003-10-02 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-11-12 |
Time |
17:24 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-10-02 |
Time |
07:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2003-09-02 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-09-02 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-09-02 |
Time |
16:35 |
Sent To |
|
|
| Notes |
| 2003-09-02 00:00:00 | 1) NOTES ON PAGE A200.OR INDICATES | | | KNOX-BOXES AT THE GATES. PLEASE | | | INDICATE WHAT WILL BE CONTAINED | | | IN THE KNOX-BOXES. WILL THEY CONTAIN | | | KEYS OR CARDS, OR CODES. | | | | | | 2) ALL GATES SHALL PROVIDE AT LEAST | | | 20 FEET IN CLEAR WIDTH. | | | | | | 3) DOES THE FIRE ACCESS LANE PAVEMENT | | | MARKING DEPICTED ON 1-200.2 INDICATE | | | TWO WAY TRAFFIC. IT IS USUALLY NOT | | | OPTIMUM FOR FIRE AND PARAMEDICAL | | | EQUIPMENT TO GO AGAINST TRAFFIC | | | PATTERNS. HOW DOES THIS ARRANGEMENT | | | WORK WHEN MULTIPLE VEHICLES EGRESS THE | | | SITE AFTER MEETINGS. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2003-04-03 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-04-03 |
Time |
12:08 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-04-03 |
Time |
12:08 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2003-11-12 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-12 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-11-12 |
Time |
14:29 |
Sent To |
E |
|
| Notes |
| 2003-11-12 00:00:00 | TO BT DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2003-09-29 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-23 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-09-23 |
Time |
16:18 |
Sent To |
|
|
| Notes |
| 2003-09-23 00:00:00 | TO COMM BD#15 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2003-09-19 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-23 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-09-19 |
Time |
12:25 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2003-08-20 |
|
|
Cont ID |
|
| Sent By |
dbaxter |
Date |
2003-08-20 |
Time |
16:13 |
Rev Time |
0.00 |
| Received By |
dbaxter |
Date |
2003-08-20 |
Time |
16:12 |
Sent To |
E |
|
| Notes |
| 2003-08-20 00:00:00 | TO COMM. BOARD. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2003-08-18 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2003-08-20 |
Time |
15:38 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2003-08-18 |
Time |
14:19 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-08-07 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-08-07 |
Time |
13:37 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2003-08-07 |
Time |
13:37 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-04-16 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-16 |
Time |
10:41 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-04-16 |
Time |
10:41 |
Sent To |
E |
|
| Notes |
| 2003-04-16 00:00:00 | DP DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-04-03 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-04-03 |
Time |
15:41 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-04-03 |
Time |
15:41 |
Sent To |
B |
|
| Notes |
| 2003-04-03 00:00:00 | TO HP DESK | | | MISC BLDG BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-04-02 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-02 |
Time |
15:29 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-04-02 |
Time |
15:29 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2003-09-23 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-23 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-09-23 |
Time |
16:16 |
Sent To |
I |
|
| Notes |
| 2003-09-23 00:00:00 | OK PER ERIC SCHNEIDER/ASSOC PLANNER MM |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2003-08-18 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-19 |
Time |
12:25 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
|
Time |
|
Sent To |
I |
|
| Notes |
| 2003-08-20 00:00:00 | 8/18/03 DENIED PER SHIRLEY GRAHAM NEED | | | SEPERATE PERMIT FOR WELCOME KIOSK MM |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-04-17 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-08-18 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-04-17 00:00:00 | OK, PER SG. |
|
|