Plan Review Details - Permit 03040134
| Plan Review Stops For Permit 03040134 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2003-05-27 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-05-27 |
Time |
11:45 |
Rev Time |
1.00 |
| Received By |
sthyng |
Date |
2003-05-27 |
Time |
11:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-04-11 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-05-27 |
Time |
10:07 |
Rev Time |
1.00 |
| Received By |
sthyng |
Date |
2003-04-11 |
Time |
17:29 |
Sent To |
P |
|
| Notes |
| 2003-04-11 00:00:00 | **********CORRECTIONS************ | | | | | | 1.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2.)PROVIDE A FOOTPRINT OF THE HOUSE | | | SHOWING LOCATIONS AND SIZES OF WINDOWS | | | TO BE REPLACED.INDICATE BEDROOM | | | WINDOWS PER FBC 1005.4.SHOW DOOR | | | LOCATIONS OF DOORS TO BE REPLACED. | | | | | | 3.)PROVIDE TWO COPIES OF PRODUCT | | | APPROVALS FOR THE WINDOWS. | | | | | | 4.)PROVIDE TWO COPIES OF PRODUCT | | | APPROVALS FOR THE DOORS IF THEY ARE | | | EXTERIOR DOORS. | | | | | | 5.)REPLACEMENT WINDOWS REQUIRE | | | HURRICANE PROTECTION AS PER | | | FBC 3401.7.2.4.IF HURRICANE SHUTTERS | | | ARE TO BE INSTALLED UNDER THIS PERMIT, | | | ADD THAT ITEM TO THE APPLICATION AND | | | PROVIDE TWO COPIES OF PRODUCT APPROVALS. | | | IF YOU DO NOT ADD SHUTTERS TO THE SCOPE | | | OF WORK FOR THIS PERMIT, YOU WILL BE | | | REQUIRED TO APPLY FOR A HURRICANE | | | SHUTTER PERMIT SEPARATELY. | | | | | | IF YOU HAVE ANY QUESTIONS, CALL | | | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | | 561-805-6724 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2003-04-10 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-05-27 |
Time |
10:07 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2003-04-10 |
Time |
02:04 |
Sent To |
B |
|
| Notes |
| 2003-04-10 00:00:00 | REDLINED AIC RATING FOR MAIN | | | | | | SENT TO MISC INBOX. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-05-19 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-19 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-19 |
Time |
15:05 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-04-04 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-04-04 |
Time |
09:15 |
Rev Time |
0.00 |
| Received By |
sthyng |
Date |
2003-04-04 |
Time |
09:15 |
Sent To |
E |
|
| Notes |
| 2003-04-04 00:00:00 | TO ELEC INBOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2003-05-27 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-05-24 |
Time |
13:23 |
Rev Time |
0.20 |
| Received By |
pkrauss |
Date |
2003-05-27 |
Time |
10:05 |
Sent To |
B |
|
| Notes |
| 2003-05-27 00:00:00 | NO MECHANICAL PLANS SUBMITTED FOR REVIEW | | | NOTE ON ELEC SHEET INDICATES FIRE DAMAGE | | | AND THE ONLY WORK BEING DONE TO THE A/C | | | WAS THE WIRING. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2003-05-24 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-19 |
Time |
15:09 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2003-05-24 |
Time |
13:21 |
Sent To |
M |
|
| Notes |
| 2003-05-24 00:00:00 | NO PLUMBING PLANS SUBMITTED/REQUIRED. | | | FIXTURE CHANGE OUT ONLY |
|
|
|