| Plan Review Stops For Permit 03032420 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2003-05-20 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2003-05-20 |
Time |
10:34 |
Rev Time |
0.25 |
| Received By |
jgomez |
Date |
2003-05-20 |
Time |
10:34 |
Sent To |
|
|
| Notes |
| 2003-05-20 00:00:00 | PROVISO: | | | 1-PROVIDE SOIL TEST REPORT PRIOR TO | | | CONSTRUCTION. | | | 2-RESUBMIT CORRECT STORM SHUTTERS | | | INFORMATION TO MATCH DESIGN PRESSURES | | | CALCULATED BY THE ARCHITECT. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
|
Date |
2003-05-13 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-16 |
Time |
16:35 |
Rev Time |
2.00 |
| Received By |
jgomez |
Date |
2003-05-13 |
Time |
16:19 |
Sent To |
PC |
|
| Notes |
| 2003-05-13 00:00:00 | BUILDING REVIEW APPROVED WITH PROVISO: | | | 1-PROVIDE SOIL TEST REPORT PRIOR TO | | | CONSTRUCTIONNOT AT TIME OF SLAB | | | INSPECTION. DENSITY TEST IS THE ONE | | | TO BE COLLECTED AT TIME OF SLAB | | | INSPECTION. | | | 2-PROVIDE COMPLETE/CORRECT INFORMATION | | | FOR STORM SHUTTERS UNDER A SEPARATE | | | PERMIT: A)REVISE DESIGN PRESSURES. SEE | | | DESIGN PRESSURES CALCULATED BY THE | | | ARCHITECT. B)SEE ENGINEERED DRAWINGS | | | FOR MAX./MIN. PANEL SIZE ACCORDING TO | | | DESIGN PRESSURES & REVISE INSTALLATION | | | SCHEDULE AS REQUIRED. C)CLEARLY MARK/ | | | CIRCLE ON ENGINEERED DRAWINGS THE | | | MOUNTING CONDITIONS, TYPE AND ANCHOR | | | SPACING ACCORD'G TO THE EDGE DISTANCE, | | | DESIGN PRESSURES, CONNECTION TYPE, | | | PANEL SPAN & STRUCTURE TO BE ATTACHED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
|
Date |
2003-04-30 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-09 |
Time |
16:09 |
Rev Time |
3.00 |
| Received By |
jgomez |
Date |
2003-04-30 |
Time |
10:59 |
Sent To |
|
|
| Notes |
| 2003-04-30 00:00:00 | BUILDING REVIEW APPROVED WITH PROVISO: | | | 1-PROVIDE SOIL TEST REPORT PRIOR TO | | | CONSTRUCTION. | | | 2-PROVIDE COMPLETE/CORRECT INFORMATION | | | FOR STORM SHUTTERS UNDER A SEPARATE | | | PERMIT. | | | 3-RESUBMIT PRODUCT APPROVAL FOR SINGLE | | | HUNG WINDOWS WITH LEGIBLE DRAWINGS. | | | 4-REVISE SPECIFICATIONS FOR INSTALLATION | | | OF METHAL LATH AT PORCH CEILING. SEE | | | SHEET A2. FASTENER TO HAVE 1 3/4" MIN. | | | PENETRATION TO THE HORIZONTAL MEMBER. | | | SEE ASTM C-1063 AND REVISE AS REQUIRED |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2003-12-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-12-22 |
Time |
15:28 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2003-12-22 |
Time |
15:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2003-04-10 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-19 |
Time |
14:27 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2003-04-10 |
Time |
03:17 |
Sent To |
P |
|
| Notes |
| 2003-04-10 00:00:00 | ********** NOTES REDLINED *********** | | | | | | PLEASE SEE CIRCUITING FOR GEN LT IN SUB- | | | PANEL. SHOWS 10 CIR AT 60A #6? | | | SHOULD BE 15A/20A #14/12? | | | | | | 1)NOTE: PLEASE SEE MISSING EQUIPMENT | | | GROUNDING CONDUCTOR BETWEEN MAIN PANEL | | | AND SUB PANEL. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-12-19 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-19 |
Time |
14:27 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-19 |
Time |
14:27 |
Sent To |
E |
|
| Notes |
| 2003-12-19 00:00:00 | TO DP DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-05-16 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-16 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-16 |
Time |
16:35 |
Sent To |
B |
|
| Notes |
| 2003-05-16 00:00:00 | JGOMEZ DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-05-09 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-09 |
Time |
16:09 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-09 |
Time |
16:09 |
Sent To |
B |
|
| Notes |
| 2003-05-09 00:00:00 | JGOMEZ DESK. RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-04-01 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-04-01 |
Time |
10:30 |
Rev Time |
0.00 |
| Received By |
sthyng |
Date |
2003-04-01 |
Time |
10:30 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2003-04-19 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2003-04-16 |
Time |
17:17 |
Rev Time |
0.33 |
| Received By |
rregueir |
Date |
2003-04-19 |
Time |
12:00 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2003-04-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-04-10 |
Time |
03:18 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2003-04-16 |
Time |
17:16 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-04-30 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-04-01 |
Time |
10:30 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2003-04-30 |
Time |
10:59 |
Sent To |
|
|
| Notes |
| 2003-04-30 00:00:00 | APPROVED BY SHIRLEY 4-3-03. SEE SURVEY. |
|
|