| Plan Review Stops For Permit 03032245 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2003-05-05 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-05-05 |
Time |
13:24 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-05-05 |
Time |
13:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-04-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-05-05 |
Time |
08:41 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-04-21 |
Time |
12:54 |
Sent To |
|
|
| Notes |
| 2003-04-21 00:00:00 | SHOW THE DESIGN LOADS FOR THE TRUSSES. | | | | | | SHOW A DETAIL FOR THE CONNECTION OF THE | | | NEW TRUSSES TO THE EXISTING ROOF | | | TRUSSES AND AN ANALYSIS OF THE EXISTING | | | TRUSSES ABILITY TO ASSUME THE | | | ADDITIONAL LOADING.SEE FBC 2309.2.4. | | | | | | SHOW THE ATTIC ACCESS IN ACCORDANCE WITH | | | FBC 2309.6 AND THE VENTILATION TO 2309. | | | 7. | | | | | | SHOW THE DESIGN WIND PRESSSURES FOR THE | | | ROOF COVERING IN EACH ZONE, AND OTHER | | | INFORMATION.SEE FBC 104.2.1.1. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2003-06-09 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-06-09 |
Time |
10:02 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2003-06-09 |
Time |
09:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2003-05-05 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-06 |
Time |
14:27 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-05-05 |
Time |
08:40 |
Sent To |
B |
|
| Notes |
| 2003-05-05 00:00:00 | ************** PROVISO/REVISE ********* | | | | | | 1)NOTE: PLEASE REDRAW PLANS BEFORE ROUGH | | | ALONG WITH ANY CHANGES. | | | | | | 2)NOTE: PLEASE SEE RISER, SHOWS 6-3/0`S? | | | FOR A 200A DISC? PLEASE CLARIFY? | | | | | | PLEASE PRINT ALL CLEARLY. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-04-09 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-04-28 |
Time |
11:34 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2003-04-09 |
Time |
04:56 |
Sent To |
M |
|
| Notes |
| 2003-04-09 00:00:00 | *************** UNSAT *************** | | | | | | 1)NOTE: PLEASE CORRELATE PANEL SCHEDULES | | | / LOAD CALCULATIONS. PLEASE REVISE LOAD | | | CALCULATIONS.220-3 | | | SOME LOADS MISSING ON LOAD CALCS. | | | BOTH SUB-PANELS ARE NOT SHOWN ON MAIN | | | PANEL SCHEDULE? | | | POOL EQUIPMENT LOADS NEED TO CORRELATE | | | W/ LOAD CALCS. | | | PANEL MENTIONS EXISTING 2P-70A AND | | | PANEL SCHEDULE FOR MAIN PANEL SHOWS | | | ONLY ONE SUB PANEL AND IT IS SHOWN AT | | | 60A?? PLEASE CORRRELATE. | | | | | | 2)NOTE: PLEASE SHOW LOCATION OF NEW | | | PANEL AND GROUPING OF MAINS PER 230-72 | | | | | | 3)NOTE: PLEASE SEE PLANS, TWO DIFFERENT | | | EXISTING RISER DIAGRAMS SUBMITTED FOR | | | REVIEW? PLEASE ONLY SUBMIT THE ACTUAL | | | EXISTING. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 | | | [email protected]. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-06-06 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-06 |
Time |
14:26 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-06-06 |
Time |
14:26 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-04-28 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-04-28 |
Time |
11:33 |
Rev Time |
0.00 |
| Received By |
sthyng |
Date |
2003-04-28 |
Time |
11:33 |
Sent To |
E |
|
| Notes |
| 2003-04-28 00:00:00 | TO DP DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-04-07 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-07 |
Time |
15:16 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-04-07 |
Time |
15:15 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-04-01 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2003-04-04 |
Time |
10:24 |
Rev Time |
0.00 |
| Received By |
sthyng |
Date |
2003-04-01 |
Time |
16:25 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2003-04-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-04-09 |
Time |
04:57 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2003-04-09 |
Time |
13:56 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2003-04-11 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-04-09 |
Time |
13:57 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2003-04-11 |
Time |
15:40 |
Sent To |
B |
|
| Notes |
| 2003-04-11 00:00:00 | NO PLUMBING PLANS SUBMITTED |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-04-04 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-04-01 |
Time |
16:25 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
I |
|
| Notes |
|
|