Plan Review Details - Permit 03032192
Plan Review Stops For Permit 03032192
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-05-02 Cont ID  
Sent By rmcdouga Date 2003-05-02 Time 09:05 Rev Time 1.00
Received By rmcdouga Date 2003-05-02 Time 09:05 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-04-24 Cont ID  
Sent By shernand Date 2003-04-25 Time 09:25 Rev Time 3.00
Received By rmcdouga Date   Time   Sent To  
Notes
2003-04-22 00:00:00BUILDING DENIED
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) THE CBS WALL (FENCE) WILL REQUIRE A
 SEPARATE PERMIT. A UTILITY EASEMENT
 RELEASE IS REQUIRED BEFORE PERMIT CAN BE
 ISSUED.
  
 3) THE GUTTER DOWN SPOUTS ARE REQUIRED
 TO DISCHARGE A MINIMUM OF ONE FOOT FROM
 THE STRUCTURE SIDEWALLS PER FBC 1503.4.4
  
 4) THE CONNECTORS SPECIFIED ARE
 MANUFACTURED BY HUGHES WHICH WAS
 PURCHASED BY USP SOMETIME AGO. PLEASE
 UPDATE CONNECTORS TO CURRENT USP OR
 SIMPSON PRODUCTS.
  
 5) SPECIFY WASHERS FOR THE 5/8" J BOLTS
 ANCHORING THE 2X BASE PLATE TO THE STEM
 WALL.
  
 6) THE PT BASE PLATE ON THE STEM WALL IS
 SPECIFIED AS A 2X8, BUT APPEARS TO BE A
 2X6. PLEASE CLARIFY.
  
 7) CLARIFY HOW THE 2X8 LEDGER WILL BE
 BOLTED TO THE EXTISTING STRUCTURE. WILL
 IT BE THROUGH BOLTED TO THE EXISTING
 FLOOR SILL? SPECIFY WASHER TYPE/SIZE.
  
 8) THE WINDOWS ON THE ELEVATIONS ARE
 SHOWN AS SINGLE HUNG (EXCEPT AT KITCHEN
 AND DINING ROOM) AND PLANS ON A2 DO NOT
 INDICATE SH WINDOWS. PLEASE INDICATE
 WHICH WINDOWS ARE SINGLE HUNG, CASEMENT
 AND FIXED.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-04-03 Cont ID  
Sent By sthyng Date 2003-04-01 Time 11:38 Rev Time 0.25
Received By dpalmer Date 2003-04-03 Time 05:19 Sent To P
Notes
2003-04-03 00:00:00NOTED ON PLAN. 210-8-A-6

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-04-25 Cont ID  
Sent By shernand Date 2003-04-25 Time 09:25 Rev Time 0.00
Received By shernand Date 2003-04-25 Time 09:25 Sent To B
Notes
2003-04-25 00:00:00RM DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-04-01 Cont ID  
Sent By sthyng Date 2003-04-01 Time 11:37 Rev Time 0.00
Received By sthyng Date 2003-04-01 Time 11:37 Sent To E
Notes
2003-04-01 00:00:00TO ELECTRIC IN BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-03-27 Cont ID  
Sent By sthyng Date 2003-04-01 Time 11:31 Rev Time 0.00
Received By sthyng Date 2003-03-27 Time 14:48 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2003-04-04 Cont ID  
Sent By kstevens Date 2003-04-03 Time 18:00 Rev Time 0.15
Received By pkrauss Date 2003-04-04 Time 11:17 Sent To B
Notes
2003-04-04 00:00:00HISTORIC- NO INFORMATION OR PLANS
 SUBMITTED FOR REVIEW.

Review Stop P PLUMBING
Rev No 1 Status N Date 2003-04-03 Cont ID  
Sent By dpalmer Date 2003-04-03 Time 05:20 Rev Time 0.25
Received By kstevens Date 2003-04-03 Time 17:55 Sent To M
Notes
2003-04-03 00:00:00NO PLUMBING PLANS SUBMITTED
 NO PLUMBING PLANS SUBMITTED

Review Stop Z ZONING
Rev No 1 Status P Date 2003-04-01 Cont ID  
Sent By sthyng Date 2003-03-28 Time 14:48 Rev Time 0.50
Received By sthyng Date 2003-03-27 Time 11:30 Sent To I
Notes
2003-04-01 00:00:00SIGNED OFF BY SG - STAMP ON PLAN