Plan Review Details - Permit 03032132
Plan Review Stops For Permit 03032132
Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2003-07-10 Cont ID  
Sent By sthyng Date 2003-07-10 Time 07:33 Rev Time 0.50
Received By sthyng Date 2003-07-10 Time 07:33 Sent To  
Notes
2003-07-10 00:00:00WALL FRAMING DETAIL FOR DOOR & WINDOW

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status F Date 2003-07-08 Cont ID  
Sent By shernand Date 2003-07-09 Time 16:17 Rev Time 1.00
Received By sthyng Date 2003-07-08 Time 09:50 Sent To  
Notes
2003-07-08 00:00:00******CORRECTIONS*******
  
 1.)SUBMIT TWO COPIES OF THE SEALED
 PLAN FOR PERMITTING.ONLY ONE WAS
 SUBMITTED.
  
 2.)THE SCOPE OF WORK FOR THIS JOB
 IS GREATER THAN $2500.A NOTICE OF
 COMMENCEMENT IS REQUIRED TO BE FILED
 WITH THE CLERK OF COURTS.
  
 3.)THERE IS A HOLD ON THIS PROPERTY
 (SEE ATTACHED).

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2003-05-06 Cont ID  
Sent By shernand Date 2003-07-08 Time 09:43 Rev Time 0.50
Received By sthyng Date 2003-05-06 Time 13:15 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2003-04-09 Cont ID  
Sent By shernand Date 2003-05-06 Time 11:16 Rev Time 1.00
Received By sthyng Date 2003-04-09 Time 18:33 Sent To  
Notes
2003-04-09 00:00:00**********CORRECTIONS************
  
 1.)PLEASE SEE NOTE #1 ON PREVIOUS
 CORRECTION NOTICE.WINDOWS MARKED
 EGRESS ON THE PLAN DO NOT MEET OPENING
 REQUIREMENTS.
  
 2.)SECOND FLOOR BEDROOM WINDOWS ARE
 REQUIRED TO BE EITHER IMPACT GLASS OR
 TO HAVE SHUTTERS THAT CAN BE OPENED FROM
 THE INSIDE.SEE PREVIOUS 2 CORRECTION
 NOTICES.
  
 3.)PROVIDE 2 COPIES OF MULLION
 PRODUCT APPROVALS.
  
 4.)FEES HAVE BEEN ASSESSED ON THIS
 PROPERTY.A PERMIT CANNOT BE ISSUED
 UNTIL THESE FEES ARE PAID.ATTACHED
 PLEASE FIND FEE INFORMATION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 SAMANTHA THYNG, BUILDING PLANS EXAMINER
 561-805-6724
 EMAIL [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2003-04-07 Cont ID  
Sent By shernand Date 2003-04-09 Time 16:45 Rev Time 1.00
Received By sthyng Date 2003-04-07 Time 11:58 Sent To  
Notes
2003-04-07 00:00:00**********CORRECTIONS************
  
 1.)THE BEDROOM WINDOWS DO NOT MEET
 EGRESS OPENING REQUIREMENTS:
 2001 FL BLD CODE, 1005.4:
 PROVIDE EMERGENCY EGRESS WINDOWS IN
 SLEEPING ROOMS WITH A MINIMUM NET CLEAR
 OPENING HEIGTH OF 24" AND NET CLEAR
 OPENING WIDTH OF 20" AND A NET CLEAR
 OPENING AREA OF 5.7 SQ.FT. GROUND FLOOR
 OPENINGS ARE PERMITTED TO HAVE A NET
 CLEAR OPENING OF 5.0 SQ. FT. SILL HEIGTH
 SHALL NOT BE MORE THAN 44 " ABOVE THE
 FINISH FLOOR.
  
 2.)ON RESUBMITTAL, PLEASE CLEARLY
 MARK BEDROOM WINDOWS ON THE ELEVATIONS
 OR INDICATE NORTH ON THE FLOOR PLANS.
  
 3.)THE HURRICANE SHUTTERS SELECTED
 DO NOT APPEAR TO MEET EGRESS
 REQUIREMENTS FOR THE BEDROOM WINDOWS.
 PLEASE CLARIFY.
  
 4.)PLEASE ADDRESS COMMENT #4 FROM
 THE PREVIOUS CORRECTION NOTICE.PROVIDE
 MULLION PRODUCT APPROVALS.
  
 5.)PLEASE ADDRESS COMMENT #5 FROM
 THE PREVIOUS CORRECTION NOTICE.
  
 WHEN RESUBMITTING PLANS PLEASE CLEARLY
 INDICATE THE REVISION AND SUBMIT ONE
 SET OF THE OLD DRAWINGS WITH
 THE PLANS WHEN RESUBMITTING PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, WILL HELP TO EXPEDITE
 YOUR PERMIT.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 SAMANTHA THYNG, BUILDING PLANS EXAMINER
 561-805-6724

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-03-31 Cont ID  
Sent By shernand Date 2003-04-03 Time 12:53 Rev Time 0.75
Received By lsmith Date   Time   Sent To  
Notes
2003-03-31 00:00:00*******************FAILED***********
  
 1. DRAWINGS MUST SHOW DIMENSIONS OF
 OPENINGS WITH PRESSURE.
 2. DRAWING MUST DESIGNATE BEDROOM
 LOCATIONS AND EGRESS PER FBC 2001
 1005.4.4
 3. ALL OPENINGS MUST HAVE STORM PANELS
 PER FBC 2001. NEED PRODUCT APPROVALS.
 PER FBC 2001 1606.1.4.
 4. PRODUCT APPROVALS MUST BE SUBMITTED
 FOR MULLINS INSTALLED WHERE 2 WINDOWS
 ARE JOINED IN AN OPENING.
 5. 4X FEE WAS ASSESSED ON THIS PROPERTY.
 ADDITIONAL FEES MUST BE PAID BEFORE
 PERMIT CAN BE ISSUED.
  
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 805-6713

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2003-07-09 Cont ID  
Sent By shernand Date 2003-07-09 Time 16:17 Rev Time 0.00
Received By shernand Date 2003-07-09 Time 16:17 Sent To B
Notes
2003-07-09 00:00:00STHYNG DESK

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2003-07-08 Cont ID  
Sent By shernand Date 2003-07-08 Time 09:43 Rev Time 0.00
Received By shernand Date 2003-07-08 Time 09:43 Sent To B
Notes
2003-07-08 00:00:00STHYNG DESK

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-05-06 Cont ID  
Sent By shernand Date 2003-05-06 Time 11:16 Rev Time 0.00
Received By shernand Date 2003-05-06 Time 11:16 Sent To B
Notes
2003-05-06 00:00:00STHYNG DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-04-09 Cont ID  
Sent By shernand Date 2003-04-09 Time 16:44 Rev Time 0.00
Received By shernand Date 2003-04-09 Time 16:44 Sent To B
Notes
2003-04-09 00:00:00STHYNG DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-04-03 Cont ID  
Sent By shernand Date 2003-04-03 Time 12:52 Rev Time 0.00
Received By shernand Date 2003-04-03 Time 12:52 Sent To B
Notes
2003-04-03 00:00:00MISC BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-03-26 Cont ID  
Sent By sthyng Date 2003-03-26 Time 15:29 Rev Time 0.00
Received By sthyng Date 2003-03-26 Time 15:29 Sent To B
Notes
2003-03-26 00:00:00TO BLDG MISC BOX