Plan Review Details - Permit 03031952
Plan Review Stops For Permit 03031952
Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2003-09-08 Cont ID  
Sent By jgomez Date 2003-09-08 Time 09:33 Rev Time 0.50
Received By jgomez Date 2003-09-08 Time 09:33 Sent To PC
Notes
2003-09-08 00:00:00MINOR REVISIONS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2003-06-27 Cont ID  
Sent By kstevens Date 2003-09-06 Time 18:56 Rev Time 0.25
Received By jgomez Date 2003-06-27 Time 11:37 Sent To PC
Notes
2003-06-27 00:00:00PERMIT FEES PAID. PLANS APPROVED WITH
 PROVISO DATED 6-18-03.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status   Date 2003-06-23 Cont ID  
Sent By shernand Date 2003-06-26 Time 08:36 Rev Time 0.25
Received By jgomez Date 2003-06-23 Time 09:03 Sent To PC
Notes
2003-06-23 00:00:00NEED TO PAY IMPACT FEES TO PASS BUILDING
 STOP. OTHERWISE, PASSED WITH PROVISO.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status   Date 2003-06-18 Cont ID  
Sent By pkrauss Date 2003-06-23 Time 07:12 Rev Time 3.00
Received By jgomez Date 2003-06-18 Time 17:29 Sent To E
Notes
2003-06-18 00:00:00BUILDING REVIEW APPROVED WITH PROVISO:
 1-PROVIDE SOIL TEST REPORT. "MASTER SOIL
 TEST" IS PRELIMINARY AND CALLS FOR
 ADDITIONAL BORINGS ON THE LIMITATIONS.
 2-RESUBMIT STORM SHUTTERS:
 A)DESIGN PRESSURES ARE LOWER THAN THOSE
 CALCULATED BY THE ARCHITECT OF RECORD.
 B)REVISE SIZE OF PANEL SPAN. SEE THE
 ENGINEERED DRAWINGS FOR MIN. SIZE.
 C)CLEARLY MARK ON THE ENGINEERED DWGS
 ANCHOR TYPE AND SPACING TO BE USED
 ACCORDING TO THE EDGE DISTANCE (THIS
 MAKES A BIG DIFFERENCE ON THE ANCHOR
 SPACING), DESIGN PRESSURE, PANEL SPAN,
 CONNECTION TYPE AND STRUCTURE TO BE
 ATTACHED TO.
  
 3-PROVIDE STRUCTURAL BUCK DETAIL FOR
 GARAGE DOOR. SEC. 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001.
 4-SPECIFY SAFETY GLASS FOR GLASS BLOCK
 BY TUB & SHOWER AREA IF FACE THICKNESS
 OF GLASS BLOCK IS LESS THAN 0.25".
 SEE SEC. 2405.2 FBC 2001.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2003-05-13 Cont ID  
Sent By shernand Date 2003-06-12 Time 08:17 Rev Time 2.50
Received By jgomez Date 2003-05-13 Time 12:18 Sent To M
Notes
2003-05-13 00:00:00BUILDING CHECKLIST:
 1-REAR ELEVATION EXCEEDS THE MAXIMUM
 PERCENTAGE OF OPENINGS ALLOWED BY
 TABLE 600 FBC 2001.
 **NOTE: TABLE 600 REFERS TO OPENINGS IN
 THE WALL AREA, NOT GLASS AREA IN THE
 OPENING.
 2-PROVIDE SOIL TEST REPORT NOW. NOT AT
 TIME OF CONCRETE SLAB. THIS IS PART
 OF PLAN REVIEW AND INFORMATION NEEDED
 BY DESIGNER TO DESIGN FOOTINGS ETC.
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.
 3-PAY IMPACT FEES AND BRING BACK PAID
 RECEIPT AND STAMPED DRAWINGS.
 4-STORM SHUTTERS:
 A)REVISE DESIGN PRESSURES. SEE PLANS FOR
 CALCULATED PRESSURES BY THE ARCHITECT.
 B)SEE ENGINEERED DRAWINGS FOR MAXIMUM
 AND MINIMUM PANEL SPAN ACCORDING TO
 THE DESIGN PRESSURES.
 C)CLEARLY MARK/CIRCLE ON STORM SHUTTERS
 DRAWINGS THE MOUNTING CONDITIONS AND
 ANCHOR TYPE AND SPACING TO BE USED
 ACCORDING TO THE EDGE DISTANCE, DESIGN
 PRESSURES, CONNECTION TYPE, PANEL SPAN
 AND STRUCTURE TO BE ATTACHED TO.
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.
  
 5-PROVIDE PRODUCT APPROVAL FOR FRENCH
 DOORS WITH SIDELITES SINGLE ASSEMBLY
 AS SHOWN ON PLANS. **BROWARD COUNTY
 PRODUCT APPROVAL IS NOT ACCEPTABLE.
 PROVIDE DADE COUNTY, SBCCI OR SITE
 SPECIFIC ENGINEERING(SEE ATTACHED CITY
 SAMPLE FORM FOR SITE SPECIFIC DOOR)
 SIGNED AND SEALED BY THE ENGINEER AND
 BY THE DESIGNER OF RECORD.
 **NOTE: ENGINEER TO CLARIFY WHY FORM
 SUBMITTED SAYS THAT 2X BUCK DETAIL IS
 NOT STRUCTURAL.
 6-CLARIFY WHY PERMIT APPLICATION AND
 ENERGY CALCULATIONS HAVE DIFFERENT
 CONTRACTORS NAME.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-04-30 Cont ID  
Sent By shernand Date 2003-05-09 Time 16:14 Rev Time 3.00
Received By jgomez Date 2003-04-29 Time 17:36 Sent To  
Notes
2003-04-29 00:00:00BUILDING REVIEW CHECKLIST:
 1-REAR ELEVATION EXCEEDS THE MAXIMUM
 PERCENTAGE OF OPENINGS ALLOWED BY
 TABLE 600 FBC 2001. REVISE AS REQUIRED
 2-PROVIDE SOIL TEST REPORT.
 3-PAY IMPACT FEES BRING BACK STAMPED
 DRAWINGS AND PAID RECEIPT.
 4-NEED RECORDED NOTICE OF COMMENCEMENT.
 5-STORM SHUTTERS: A)DRAWINGS NEED TO
 HAVE ENGINEER'S SEAL AND SIGNATURE AS
 REQUIRED BY DESIGNER ENGINEER ON NOTE
 #6 ON PAGE 1 OF 9.
 B)DRAWINGS DON'T MATCH THOSE REFERENCED
 ON SBCCI REPORT. SEE NUMBER OF DWGS
 AND LATEST REVISIONS.
 **NOTE: THERE IS AN UPDATED SBCCI REPORT
 #2229A. ALSO, GET MATCHING DRAWINGS.
 C)CHECK THE DESIGN PRESSURES AND MAX./
 MIN. PANEL SPAN SHOWN ON INSTALLATION
 SCHEDULE AND THOSE SHOWN ON ENGINEERED
 DRAWINGS AND REVISE SCHEDULE AS REQ'D.
 ALSO, CHECK ANCHOR SPACING.
  
 6-A)PROVIDE PRODUCT APPROVAL FOR FRENCH
 DOORS WITH SIDELITES AS SHOWN ON PLANS
 B)RESUBMIT PRODUCT APPROVAL FOR SINGLE
 HUNG WINDOWS WITH LEGIBLE DRAWINGS.
  
 7-REVISE SPECIFICATIONS FOR INSTALLATION
 OF METAL LATH AT PORCH CEILING. SEE
 ASTM C-1063 FOR SIZE OF FASTENER
 REQUIRED. NEED 1 3/4" PENETRATION TO
 HORIZONTAL MEMBER AND 1 3/4" STAPLES
 DON'T PROVIDE THIS REQUIREMENT. REVISE
 SPECIFICATIONS AS REQUIRED.
 8-PROVIDE COMPLETE DETAIL AND FASTENERS
 SPECIFICATIONS FOR INSTALLATION OF
 AIR HANDLER UNIT HANGING FROM TRUSSES.
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.
 9-COMPLETE INFORMATION ON TOP OF THE
 ENERGY CALCULATIONS. EG: OWNER.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-08-27 Cont ID  
Sent By btrobaug Date 2003-08-27 Time 18:08 Rev Time 0.33
Received By btrobaug Date 2003-08-27 Time 18:02 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-06-19 Cont ID  
Sent By csiegber Date 2003-08-27 Time 15:36 Rev Time 0.50
Received By btrobaug Date 2003-06-19 Time 10:43 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-04-09 Cont ID  
Sent By jgomez Date 2003-06-18 Time 17:29 Rev Time 0.25
Received By dpalmer Date 2003-04-09 Time 03:29 Sent To P
Notes
2003-04-09 00:00:00********* NOTE ************
  
 SUB PANEL SHOWS ALL GEN LT CIRCUITS AS
 60A AND #6 AWG.?
 15/20A #14/#12 AWG,,,,,
  
  
 IF THERE ARE ANY QUESTIONS, PLEASE CALL.
  
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2003-08-27 Cont ID  
Sent By csiegber Date 2003-08-27 Time 15:31 Rev Time 0.00
Received By csiegber Date 2003-08-27 Time 15:31 Sent To E
Notes
2003-08-27 00:00:00TO BT DESK

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-06-26 Cont ID  
Sent By shernand Date 2003-06-26 Time 08:36 Rev Time 0.00
Received By shernand Date 2003-06-26 Time 08:36 Sent To B
Notes
2003-06-26 00:00:00JGOMEZ DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-06-12 Cont ID  
Sent By shernand Date 2003-06-12 Time 08:17 Rev Time 0.00
Received By shernand Date 2003-06-12 Time 08:17 Sent To B
Notes
2003-06-12 00:00:00JGOMEZ DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-05-09 Cont ID  
Sent By shernand Date 2003-05-09 Time 16:14 Rev Time 0.00
Received By shernand Date 2003-05-09 Time 16:14 Sent To B
Notes
2003-05-09 00:00:00JGOMEZ DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-03-25 Cont ID  
Sent By dpalmer Date 2003-03-25 Time 09:51 Rev Time 0.00
Received By dpalmer Date 2003-03-25 Time 09:50 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2003-06-23 Cont ID  
Sent By pkrauss Date 2003-06-23 Time 07:12 Rev Time 0.25
Received By pkrauss Date 2003-06-23 Time 07:12 Sent To B
Notes
2003-06-23 00:00:00MECHANICAL PERMIT 03031954
 APPROVED 5-14-03, NO CHANGES WITH THIS
 SUBMITTAL.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-05-15 Cont ID  
Sent By jleech Date 2003-06-21 Time 07:15 Rev Time 0.20
Received By pkrauss Date 2003-05-15 Time 09:53 Sent To B
Notes
2003-05-15 00:00:00MECHANICAL PERMIT 03031954

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-04-19 Cont ID  
Sent By jgomez Date 2003-05-13 Time 13:20 Rev Time 0.50
Received By jleech Date 2003-04-19 Time 06:53 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2003-09-06 Cont ID  
Sent By kstevens Date 2003-09-06 Time 18:56 Rev Time 0.33
Received By kstevens Date 2003-09-06 Time 18:56 Sent To B
Notes
2003-09-06 00:00:00REVISION OK - SANT. RISER DIAGRAM - CHG.
 LOCATION OF L/SINK

Review Stop P PLUMBING
Rev No 2 Status P Date 2003-06-21 Cont ID  
Sent By btrobaug Date 2003-08-27 Time 18:08 Rev Time 0.25
Received By jleech Date 2003-06-21 Time 07:15 Sent To M
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-04-14 Cont ID  
Sent By btrobaug Date 2003-06-19 Time 11:15 Rev Time 0.50
Received By jleech Date 2003-04-14 Time 18:54 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-04-03 Cont ID  
Sent By dpalmer Date 2003-03-25 Time 09:51 Rev Time 0.00
Received By sgraham Date   Time   Sent To E
Notes
***NONE***