Plan Review Details - Permit 03031930
Plan Review Stops For Permit 03031930
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2004-06-15 Cont ID  
Sent By alange Date 2004-06-15 Time 09:51 Rev Time 1.00
Received By alange Date 2004-06-15 Time 09:50 Sent To  
Notes
2004-06-15 00:00:00REVISION OK

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-01-07 Cont ID  
Sent By jleech Date 2004-06-12 Time 07:06 Rev Time 1.50
Received By alange Date 2004-01-07 Time 16:48 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2003-04-17 Cont ID  
Sent By dpalmer Date 2004-01-06 Time 11:22 Rev Time 3.00
Received By lhatten Date 2003-04-16 Time 19:18 Sent To  
Notes
2003-04-17 00:00:00REVIEW & STAMPED PLANS 04/16/2003

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2004-01-06 Cont ID  
Sent By dpalmer Date 2004-01-06 Time 11:22 Rev Time 0.50
Received By dpalmer Date 2004-01-06 Time 11:22 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2003-11-13 Cont ID  
Sent By csiegber Date 2003-12-31 Time 14:24 Rev Time 1.00
Received By btrobaug Date 2003-11-13 Time 12:14 Sent To  
Notes
2003-11-13 00:00:00DENIED
 ~~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 PLEASE PROVIDE TWO FULL SETS OF PLANS
 FOR REVIEW.THERE IS ONLY ONE OF SHEETS
 A.5 AND A.6.ALSO HAVE THESE SHEETS
 SEALED, SIGNED AND DATED BY THE
 ARCHITECT PER FS 481 AND 16G1-16.001
 FAC THE ONES THAT WERE SUBMITTED WERE
 NOT SEALED.
  
 NOTE #2} PLEASE LIST THE REQ`D BATH(S)
 CIRCUIT(S). PER 210-11-C-3
 MUST BE 20A AND #12AWG. AND NOTE #4
 RE: REMOVE THE EQUIPMENT GROUNDING
 CONDUCTOR FROM THE METER TO THE FIRST
 MEANS OF DISCONNECT,WERE NOT CORRECTED
 ON THE PLANS.THE EQ GND IS STILL ON
 THE RISER AND CREATES A PARALLEL PATH
 WITH THE NEUTRAL CONDUCTOR.PLEASE
 REMOVE FROM PLAN.THE BATH CIRCUIT IS
 STILL ON A 15 AMP BREAKER.
  
 ALSO THE SMALL APPLIANCE CIRCUITS THAT
 ARE REQUIRED BY 210.11(C)(1) WERE NOT
 ON THE SCHEDULE AND WERE NOT IN THE
 CALCULATIONS PER 220.16(A).PLEASE
 INCLUDE SAME ON PLANS.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2003-05-05 Cont ID  
Sent By csiegber Date 2003-11-10 Time 10:26 Rev Time 0.75
Received By dpalmer Date 2003-05-05 Time 13:27 Sent To B
Notes
2003-05-05 00:00:00************* UNSAT ******************
  
 1)NOTE: PLEASE CORRELATE RISER DIAGRAM
 AND PANEL/LOADS. PANEL A IS SHOWN AS
 A MLO AND PANEL IS LISTED AS MCB ON LOAD
 CALCS.
  
 2)NOTE: PLEASE LIST THE REQ`D DEDICATED
 BATH CIRCUUIT(S) PER 210-52D/210-11C-3
 SHOWN AS #14/15A.MUST BE 20A #12
  
 3)NOTE: PLEASE LIST THE REQ`D ARC FAULT
 PROTECTED CIRCUITS ON PANEL SCHEDULE.
 210-12
  
 4)NOTE: PLEASE SEE RISER DIAGRAM, SHOWS
 AN EQUIPMENT GROUNDING CONDUCTOR FROM
 METER TO MAIN DISC. PLEASE REMOVE, ONLY
 INSTALLED AFTER FIRST MEANS OF DISC.
 250-24
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected].
  
 PLEASE INSERT NEW SHEETS, TO MAKE TWO
 COMPLETE SETS FOR REVIEW AND STAMPING.

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2005-02-16 Cont ID  
Sent By adarroug Date 2005-02-16 Time 13:55 Rev Time 0.00
Received By adarroug Date 2005-02-16 Time 13:55 Sent To P
Notes
2005-02-16 00:00:00TO KSTEVENS BOX/REVISION

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2004-11-12 Cont ID  
Sent By csiegber Date 2004-11-12 Time 11:34 Rev Time 0.00
Received By csiegber Date 2004-11-12 Time 11:34 Sent To P
Notes
2004-11-12 00:00:00TO KS BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2004-06-03 Cont ID  
Sent By csiegber Date 2004-06-03 Time 10:29 Rev Time 0.00
Received By csiegber Date 2004-06-03 Time 10:28 Sent To P
Notes
2004-06-03 00:00:00TO KS BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-12-31 Cont ID  
Sent By csiegber Date 2003-12-31 Time 14:24 Rev Time 0.00
Received By csiegber Date 2003-12-31 Time 14:24 Sent To E
Notes
2003-12-31 00:00:00TO DP DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-11-10 Cont ID  
Sent By csiegber Date 2003-11-10 Time 10:26 Rev Time 0.00
Received By csiegber Date 2003-11-10 Time 10:26 Sent To E
Notes
2003-11-10 00:00:00TO BT DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-04-29 Cont ID  
Sent By shernand Date 2003-04-29 Time 09:14 Rev Time 0.00
Received By shernand Date 2003-04-29 Time 09:14 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-03-24 Cont ID  
Sent By sthyng Date 2003-03-24 Time 15:43 Rev Time 0.00
Received By sthyng Date 2003-03-24 Time 15:43 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2004-12-03 Cont ID  
Sent By pkrauss Date 2004-12-03 Time 17:11 Rev Time 0.35
Received By pkrauss Date 2004-12-03 Time 17:11 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-04-15 Cont ID  
Sent By jleech Date 2003-04-09 Time 19:43 Rev Time 0.33
Received By rregueir Date 2003-04-15 Time 20:22 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status P Date 2005-02-17 Cont ID  
Sent By kstevens Date 2005-02-17 Time 15:58 Rev Time 0.60
Received By kstevens Date 2005-02-17 Time 15:58 Sent To  
Notes
2005-02-17 00:00:00REVISION OK - REVISION REQUIRED FOR THE
 FLOOR PLAN TO REFLECT THE SANT. RISER
 DIAGRAM

Review Stop P PLUMBING
Rev No 3 Status F Date 2004-11-27 Cont ID  
Sent By kstevens Date 2004-11-27 Time 09:36 Rev Time 0.50
Received By kstevens Date 2004-11-27 Time 09:36 Sent To M
Notes
2004-11-27 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 1) SANITARY RISER DIAGRAM DOES NOT MEET
 CODE REQUIREMENTS, NOR DOES IT REFLECT
 THE FLOOR PLAN.
 A) SHOWER NOT VENTED IN GUEST SUITE
 BATHROOM. 909.2.1
 B) MASTER BATH TUB TO BE TO THE LEFT OF
 THE LAV AS SHOWN ON THE FLOOR PLAN.
 SECTION 104.2.1
 C) EXTRA BATHROOM ON RISER DIAGRAM IS
 NOT SHOWN ON THE FLOOR PLAN. SECTION
 104.2.1
 D) 3" VENT THRU ROOF HAS NO FIXTURE ON
 THE STACK. EVERY DRY VENT CONNECTING TO
 A HORIZONTAL DRAIN SHALL CONNECT ABOVE
 THE CENTERLINE OF THE HORIZONTAL DRAIN
 PIPE. SECTION 905.3
 E) 2" TO PRO VENT HAS NO FIXTURES ON
 THE BRANCH LINE. PLEASE CLARIFY. SECTION
 104.2.1
 F) THE WASH MACHINE AND LAUNDRY SINK
 ARE NOT SHOWN ON THE RISER DIAGRAM.
 SECTION 104.2.1
 2) A TITLE BLOCK MUST APPEAR ON ALL
 ARCHITECTURAL DRAWINGS. THE TITLE BLOCK
 MUST, AT A MINIMUM, CONTAIN THE
 FOLLOWING INFORMATION:
 (1) FIRM NAME, ADDRESS, AND TELEPHONE
 NUMBER.
 (2) FIRM LICENSE NUMBER.
 (3) NAME OR IDENTIFICATION OF PROJECT.
 (4) DATE PREPARED.
 (6) A SPACE FOR THE PRINTED NAME OF THE
 PERSON SEALING THE DOCUMENT.
 FAC 61G1-16.004 & FS481.2055/481.219
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 2 Status F Date 2004-06-12 Cont ID  
Sent By jleech Date 2004-06-12 Time 07:06 Rev Time 1.00
Received By jleech Date 2004-06-12 Time 07:06 Sent To B
Notes
2004-06-12 00:00:00DENIED;
 RISER DIAGRAM NOT LEDGABLE. SEE RED
 LINED RISER DIAGRAM.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-04-09 Cont ID  
Sent By csiegber Date 2004-06-03 Time 10:29 Rev Time 0.33
Received By jleech Date 2003-04-09 Time 19:42 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-04-04 Cont ID  
Sent By sthyng Date 2003-03-24 Time 15:43 Rev Time 0.00
Received By sgraham Date   Time   Sent To E
Notes
***NONE***