Plan Review Details - Permit 03031736
Plan Review Stops For Permit 03031736
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2004-03-01 Cont ID  
Sent By btrobaug Date 2004-03-01 Time 09:51 Rev Time 0.33
Received By jgomez Date 2004-03-01 Time 09:03 Sent To E
Notes
2004-03-01 00:00:00REVISION: CHANGE OF CLOSET LOCATION.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-07-07 Cont ID  
Sent By csiegber Date 2004-02-26 Time 16:53 Rev Time 1.00
Received By jgomez Date 2003-07-02 Time 15:17 Sent To PC
Notes
2003-07-02 00:00:00BUILDING REVIEW APPROVED WITH PROVISO:
 1-PROVIDE CURRENT DADE COUNTY OR SBCCI
 PRODUCT APPROVAL AND ENGINEERED
 DRAWINGS FOR STORM SHUTTERS. INDICATE
 ANCHOR TYPE AND SPACING TO BE USED.
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-04-21 Cont ID  
Sent By btrobaug Date 2003-07-02 Time 14:27 Rev Time 1.00
Received By jgomez Date 2003-04-21 Time 14:43 Sent To  
Notes
2003-04-21 00:00:00BUILDING CHECKLIST:
 1-PROVIDE ENERGY CALCULATIONS AS REQ'D
 BY CHAPTER 13 FBC 2001.
 2-FLOOR NEEDS TO BE RAISED AT 4" ABOVE
 FINISH GRADEAS REQUIRED BY SECTION
 1804.1.7 CITY AMENDMENTS TO FBC 2001.
 3-SPECIFY SIZE AND TYPE OF WINDOWS TO
 CHECK FOR BEDROOM EGRESS REQUIREMENTS
 SEC. 1005.4 FBC 2001.
 4-NEED 1 1/2" WATER STOP RECESS AT
 MASONRY WALL. SEC. 2111.1.9 OF CITY
 AMENDMENTS TO FBC 2001.
 5-COMPLETE SPECIFICATIONS ON TYPICAL
 WALL SECTION. SPECIFY FURRING STRIPS
 FOR INSTALLATION OF DRYWALL AND
 INSULATION. SEC. 104.2.1.2 CITY AMEND-
 MENTS TO FBC 2001.
 6-CONSTRUCTION VALUE DECLARED IS TOO LOW
 NEED TO INCLUDE LABOR AND MATERIALS.
 REVISE AS REQUIRED.
 7-NEED STORM SHUTTERS PRODUCT APPROVAL
 AND INSTALLATION SCHEDULE.
 8-NEED RECORDED NOTICE OF COMMENCEMENT.
 9-AFTER CORRECTIONS ARE DONE TO ORIGINAL
 DRAWINGS, TAKE THEM TO PALM BEACH
 COUNTY BLDG (SOUTHERN BOULEVARD AND
 AUSTRALIAN AVE) TO PAY IMPACT FEES AND
 BRING BACK STAMPED DRAWINGS AND PAID
 RECEIPT.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2004-03-01 Cont ID  
Sent By btrobaug Date 2004-03-01 Time 09:51 Rev Time 0.33
Received By btrobaug Date 2004-03-01 Time 09:51 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-07-02 Cont ID  
Sent By jgomez Date 2004-03-01 Time 09:04 Rev Time 0.33
Received By btrobaug Date 2003-07-02 Time 14:26 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-03-31 Cont ID  
Sent By btrobaug Date 2003-03-31 Time 13:08 Rev Time 0.50
Received By btrobaug Date 2003-03-31 Time 12:39 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-02-26 Cont ID  
Sent By csiegber Date 2004-02-26 Time 16:53 Rev Time 0.00
Received By csiegber Date 2004-02-26 Time 16:53 Sent To B
Notes
2004-02-26 00:00:00TO JG DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-05-16 Cont ID  
Sent By shernand Date 2003-05-16 Time 11:20 Rev Time 0.00
Received By shernand Date 2003-05-16 Time 11:20 Sent To B
Notes
2003-05-16 00:00:00JGOMEZ DESK.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-03-31 Cont ID  
Sent By sthyng Date 2003-03-24 Time 16:47 Rev Time 0.00
Received By btrobaug Date 2003-03-24 Time 16:47 Sent To B
Notes
2003-03-24 00:00:00TO BLDG MISC BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-03-20 Cont ID  
Sent By sthyng Date 2003-03-20 Time 11:53 Rev Time 0.00
Received By sthyng Date 2003-03-20 Time 11:53 Sent To Z
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2003-03-24 Cont ID  
Sent By sgraham Date 2003-03-24 Time 15:43 Rev Time 0.00
Received By sgraham Date   Time   Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2003-03-24 Cont ID  
Sent By sthyng Date 2003-03-20 Time 11:53 Rev Time 0.00
Received By sgraham Date   Time   Sent To  
Notes
2003-03-24 00:00:00DENIED, NEED SURVEY SHOWING ENCLOSURE