| 2003-04-08 00:00:00 | BUILDING PLAN REVIEW |
| | PERMIT: 03031343 |
| | ADD: 700 S ROSEMARY AVE |
| | CONT: MASTER PLAN INC |
| | TEL: (561)683-9972 |
| | FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| | |
| | NOTE: MISSING CITY PLACE STAMP!!!!!! |
| | |
| | 1)FL BLD CODE 104.2.1.2 |
| | ADDITIONAL INFORMATION REQUIRED, |
| | CLARIFY THE HEIGHT OF THE COUNTER-TOP |
| | SECTION 1/A-1 INDICATES 34", NOTE# 7 |
| | INDICATES 34", BUT THE WALL SECTION |
| | 4/A-1 INDICATES 40"(3'-4"). |
| | |
| | 2) 11-4.7.2 INFORMATION COUNTERS |
| | SEE SECTION, REMEMBER CLEAR KNEE SPACE! |
| | |
| | 3) 11-4.2.4 CLEAR FLOOR SPACE, 30"X48" |
| | BLOCKS THE EGRESS TO & FROM ELEVATOR? |
| | |
| | 4) 1001.1.3 MEANS OF EGRESS SHALL CON- |
| | SIST OF CONTINUOUS AND UNOBSTRUCTED |
| | PATHS OF TRAVEL TO THE EXTERIOR OF THE |
| | BUILDING. |
| | |
| | 5) FL BLD CODE 1606.1.5: COMPONENTS & |
| | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- |
| | OLD OR RESIDENT INSPECTOR) OF PRODUCT |
| | TESTING REPORT, SBCCI OR DADE COUNTY |
| | REPORT ARE ACCEPTED.MISSING REPORT FOR |
| | SLIDING GLASS DOORS! |
| | |
| | LOOK FOR COMMENTS BY THE OTHER PLAN |
| | REVIEW DISCIPLINES THAT MAY BE WRITTEN |
| | ON THE APPLICATION, PLANS, OR ATTACHED |
| | SEPARATELY. WHEN RESUBMITTING PLANS |
| | PLEASE CLEARLY INDICATE THE REVISION AND |
| | REMOVE AND REPLACE ANY PAGES AS NECESS- |
| | ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH |
| | THE PLANS WHEN RESUBMITTING PLANS. A |
| | TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR |
| | SPECIFICATION PAGE WHERE THE CHANGES CAN |
| | BE FOUND, WILL HELP TO EXPEDITE YOUR |
| | PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | JIM WITMER |
| | BUILDING PLAN REVIEW |
| | TEL: (561)659-8096 X 8412 |
| | FAX: (561)659-8026 |