Plan Review Details - Permit 03031318
Plan Review Stops For Permit 03031318
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2003-06-10 Cont ID  
Sent By lmartine Date 2003-06-10 Time 15:32 Rev Time 1.00
Received By lmartine Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2003-05-16 Cont ID  
Sent By hpiskura Date 2003-05-16 Time 15:13 Rev Time 0.00
Received By hpiskura Date 2003-05-16 Time 15:05 Sent To  
Notes
2003-05-16 00:00:00PLANS DATED 5/14/03

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2003-05-09 Cont ID  
Sent By hpiskura Date 2003-05-09 Time 11:38 Rev Time 0.00
Received By hpiskura Date 2003-05-09 Time 11:38 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2003-05-01 Cont ID  
Sent By hpiskura Date 2003-05-01 Time 14:44 Rev Time 0.00
Received By hpiskura Date 2003-04-30 Time 12:53 Sent To  
Notes
2003-05-01 00:00:00PLEASE PROVIDE SPECIFIC CONSTRUCTION
 DETAILS AND ENGINEERING FOR THE
 INSTALLATION OF THE NEW DOORS TO BE CUT
 INTO THE WALL SHOWN AS 105B 105C AND
 E108. FBC 104.2.
  
 SHOW THE WIND DESIGN PRESSURES FOR THE
 OPENINGS IN THE EXTERIOR WALL SEE FBC
 1606.1.7.
  
 THE STORAGE AREA REQUIRES A MINIMUM TWO
 HOUR FIRE RATED SEPARATION.SEE FBC
 7041.1.
  
 THE SERVICE AREA REQUIRES A ONE HOUR
 FIRE RATED SEPARATION, (GROUP B SIM
 404.5) FROM THE MERCANTILE USE.
  
 ALL OF THE FIRE RATED WALLS REQUIRE
 FIRE RATED OPENING PROTECTION.FBC
 705.1.2.
  
 EGRESS IS NOT ALLOWED THROUGH THE
 STORAGE ROOM.SEE FBC1001.1.3.
  
 SHEET A3, WHAT IS THE NEW CEILING THAT
 IS TO MATCH THE EXISTING CEILING HEIGHT?
  
 SHEET A4, SHOW SPECIFIC CONSTRUCTION
 DETAILS AND FASTENINGS FOR THE BRACING
 OF THE PARTITIONS NOTED UNDER PARTITION
 NOTES.SEE FBC 104.2.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-04-08 Cont ID  
Sent By hpiskura Date 2003-04-08 Time 14:41 Rev Time 0.00
Received By hpiskura Date 2003-04-08 Time 14:40 Sent To  
Notes
2003-04-08 00:00:00 
 THE PLANS DO NOT HAVE ENOUGH
 INFORMATION SEE FBC 104.2.1.
  
 IT APPEARS NEW DOORS WILL BE CUT INTO
 THE SERVICE AREA.SHOW A DETAIL.
  
 SHOW A CONSTRUCTION DETAIL FOR THE
 PARTITIONS INCLUDING FIRE DESIGN NUMBER
 WHERE APPLICABLE.
  
 PROVIDE A DOOR AND WINDOW SCHEDULE.
  
 SHOW OR NOTE THE CEILING EXISTING OR
 PROPOSED.
  
 PROVIDE A FIRE RATED MIXED OCCUPANCY
 SEPARATION IN ACCORDANCE WITH FBC 704.1.
 1 FOR MERCANTILE AND STORAGE.
  
 SHOW THE FIRE RATED SEPARATION IF THIS
 IS A MULTIPLE TENANT BUILDING.
  
 SHEET A1, WHAT DOES THE DOTTED LINE
 REPRESENT BETWEEN THE RETAIL DISPLAY
 AND THE WHEEL TIRE STORAGE?
  
 SHOW THE HANDICAP ACCESSIBILITY IN
 ACCORDANCE WITH FBC 11-4.1.6 (2)
  
 SHOW THE AIR CONDITIONING WORK WHERE
 APPLICABLE.

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2003-05-16 Cont ID  
Sent By dpalmer Date 2003-05-16 Time 13:06 Rev Time 0.50
Received By dpalmer Date 2003-05-16 Time 13:06 Sent To  
Notes
2003-05-16 00:00:00*********** NOTES/ PROVISO *******
  
 1)NOTE: PLEASE SUBMIT PLAN SHOWING ALL
 NEW CIRCUITING AND CORRELATE WITH PANEL
 SCHEDULE.
 700-12E
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. BEFORE ROUGH. IF THERE ARE ANY
 QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2003-05-08 Cont ID  
Sent By dpalmer Date 2003-05-08 Time 10:24 Rev Time 0.33
Received By dpalmer Date 2003-05-08 Time 10:23 Sent To  
Notes
2003-05-08 00:00:00************** UNSAT ***************
  
 PLEASE SEE THAT THE SAME PLANS HAVE
 BEEN SUBMITTED AGAIN W/ NO COMMENTS
 ADDRESSED FROM THE FIRST TWO REVIEWS.
  
 PLEASE SEE BZ RECEIPT ATTACHED FOR A
 FOUR TIME FEE THAT HAS BEEN ADDED FOR
 PLANS REVIEW AS REQ`D UNDER FS 553.80(2)
 (B). THIS WAS MENTIONED AND LETTER WAS
 AATACHED TO PACKAGE LAST TIME PLANS WENT
 OUT FOR CORRECTIONS.
  
 PLEASE SEE NOTES FROM FIRST REVIEW,
 PLEASE ADDRESS NOTES AND IF THERE ARE
 ANY QUESTIONS, AS MENTIONS IN THE LAST
 TWO REVIEWS, PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2003-04-24 Cont ID  
Sent By nmccray Date 2003-05-08 Time 09:55 Rev Time 0.25
Received By dpalmer Date 2003-04-24 Time 17:59 Sent To  
Notes
2003-04-24 00:00:00**************** UNSAT ************
  
 1)NOTE: PLEASE SEE NOTES FROM FIRST
 REVIEW AND ADDRESS.
 NOT ALL NOTES WERE ADDRESSED.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]
  
 PLEASE SEE LETTER ATTACHED PER FS 553.80
 (2)(B).

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2003-03-26 Cont ID  
Sent By dpalmer Date 2003-03-26 Time 07:56 Rev Time 0.50
Received By dpalmer Date 2003-03-26 Time 07:56 Sent To  
Notes
2003-03-26 00:00:00********** UNSAT ****************
  
 1)NOTE: PLEASE SHOW ALL CIRCUITING ON
 PLANS AND CORRELATE WITH SUBMITTED PANEL
 SCHEDULE.
  
 2)NOTE: PLEASE SEE PLANS, PANEL SCHEDULE
 SHOWS "SHOW WINDOW" AND RECETPS ARE NOT
 SHOWN ON PLANS?
 210-62
  
 3)NOTE: PLEASE CLARIFY NEW OR EXSITNG
 SIGN CIRCUIT PER 600-5.
  
 4)NOTE: PLEASE SHOW ALL CONTINOUS LOADS
 AT 125%.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2003-06-12 Cont ID  
Sent By nmccray Date 2003-06-12 Time 10:09 Rev Time 0.00
Received By nmccray Date 2003-06-12 Time 10:09 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2003-05-08 Cont ID  
Sent By nmccray Date 2003-05-08 Time 09:55 Rev Time 0.00
Received By nmccray Date 2003-05-08 Time 09:54 Sent To E
Notes
2003-05-08 00:00:00**************PROVISO*******************
 1) LETTER INDICATING SALES OF WHEELS,
 TIRES AND SHOCKS FOR INSTALLATION ONLY.
  
 NATE MCCRAY, CAPTAIN
 659-8096, EXT 8497
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2003-05-02 Cont ID  
Sent By mcarsill Date 2003-05-02 Time 14:31 Rev Time 0.00
Received By mcarsill Date 2003-05-02 Time 14:31 Sent To  
Notes
2003-05-02 00:00:001) PLANS DO NOT INDICATE LOCATIONS
 OF ILLUMINATED EXIT SIGNS.
  
 2) PLANS AGAIN DO NOT INDICATE IF THE
 BUILDING IS FIRE SPRINKLER PROTECTED.
  
 3) NO INTERIOR FINISH CLASSIFICATION
 INFORMATION PROVIDED FOR WALLS AND
 CEILINGS.
  
 4) THE ONE HOUR WALL THAT IS BEING
 PROPOSED SHALL BE AT LEAST TWO HOUR
 FIRE RATED WITH ONE AND HALF HOUR
 OPENING PROTECTIVES. TIRE STORAGE AND
 RETAIL AREA.
  
 5) NO EXPLANATION ON HOW TIRES WILL
 BE STORED.
  
 6) PLEASE SHOW DEMISING WALLS AND
 THEIR RESPECTIVE FIRE RATINGS.
  
 7) NO OCCUPANT LOAD TOTALS PROVIDED.
  
 8) NO DETAILS ON VEHICLE STORAGE.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 659-8096,EXT.8497
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2003-04-04 Cont ID  
Sent By mcarsill Date 2003-04-04 Time 11:10 Rev Time 0.00
Received By mcarsill Date 2003-04-04 Time 11:10 Sent To  
Notes
2003-04-04 00:00:001) PLANS DO NOT INDICATE IF A FIRE
 SPRINKLER SYSTEMS EXISTS.
  
 2) PLANS DO NOT INDICATE IF ANY FIRE
 SEPARATION EXISTS BETWEEN THE WHEEL
 TIRE STORAGE AND THE OFFICES AND RETAIL
 DISPLAY.
  
 3) PLEASE EXPLAIN TIRE STORAGE. HOW
 MANY AND HOW WILL THEY BE STORED.
  
 4) NO ILLUMINATED EXIT SIGNS SHOWN
 ON PLANS.
  
 5) NO OCCUPANT LOAD TOTALS GIVEN.
  
 6) NO WALL DETAILS.
  
 7) NO DOOR DETAILS.
  
 8) NO INTERIOR FINISH CLASSIFICATION
 INFORMATION PROVIDED ON THE PLANS.
  
 9) NO DETAILS ON VEHICLE STORAGE.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 659-8096,EXT.8497
 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2003-06-06 Cont ID  
Sent By shernand Date 2003-06-06 Time 08:07 Rev Time 0.00
Received By shernand Date 2003-06-06 Time 08:07 Sent To  
Notes
2003-06-06 00:00:00COMM BOARD #25

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-05-16 Cont ID  
Sent By shernand Date 2003-05-16 Time 12:06 Rev Time 0.00
Received By shernand Date 2003-05-16 Time 12:06 Sent To  
Notes
2003-05-16 00:00:00COMM BOARD #61

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-05-07 Cont ID  
Sent By shernand Date 2003-05-07 Time 14:11 Rev Time 0.00
Received By shernand Date 2003-05-07 Time 14:11 Sent To  
Notes
2003-05-07 00:00:00COMM BOARD #11

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-04-23 Cont ID  
Sent By shernand Date 2003-04-23 Time 14:02 Rev Time 0.00
Received By shernand Date 2003-04-23 Time 13:54 Sent To  
Notes
2003-04-23 00:00:00COMM BOARD #34

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-03-17 Cont ID  
Sent By sthyng Date 2003-03-17 Time 16:18 Rev Time 0.00
Received By sthyng Date 2003-03-17 Time 16:18 Sent To  
Notes
2003-03-17 00:00:00COMM BOARD #23

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2003-04-08 Cont ID  
Sent By hpiskura Date 2003-04-08 Time 14:57 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status F Date 2003-06-12 Cont ID  
Sent By kstevens Date 2003-06-12 Time 16:53 Rev Time 0.75
Received By kstevens Date 2003-06-12 Time 16:52 Sent To  
Notes
2003-06-12 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
  
 1) SHT MEP-1 SANITARY RISER DIAGRAM &
 WATER RISER DIAGRAM. FINAL PLAN REVIEW
 NOTE FOR PLUMBING STATES THAT SANT. AND
 WATER RISERS SHALL BE SUBMITTED AT TIME
 OF PLUMBING PERMIT APPLICATION. ALL
 RISER DIAGRAM SHALL SHOW ALL PIPE SIZES,
 AND VENTING. SECTION 1-4.2.1
  
 2) ONLY FIXTURES FROM THE BATHROOM GROUP
 SHALL DRAIN INTO THE WET VENT FOR THE
 BATHROOM FIXTURES. ALL OTHER FIXTURES
 SHALL TIE IN DOWNSTREAM OF THE WET VENT.
 SECTION 909.1
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377
 (561) 805-6721
 FAX (561) 653-2692

Review Stop P PLUMBING
Rev No 3 Status N Date 2003-05-21 Cont ID  
Sent By kstevens Date 2003-05-21 Time 10:13 Rev Time 0.50
Received By kstevens Date 2003-05-21 Time 10:13 Sent To  
Notes
2003-05-21 00:00:00PLANS TO BE SUBMITTED AT TIME OF PLUMB-
 ING APPLICATION.

Review Stop P PLUMBING
Rev No 2 Status N Date 2003-05-09 Cont ID  
Sent By hpiskura Date 2003-05-09 Time 11:38 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2003-05-09 Cont ID  
Sent By hpiskura Date 2003-04-08 Time 14:57 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
***NONE***