Plan Review Details - Permit 03031261
Plan Review Stops For Permit 03031261
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-04-16 Cont ID  
Sent By lsmith Date 2003-04-16 Time 12:34 Rev Time 0.75
Received By lsmith Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-03-25 Cont ID  
Sent By btrobaug Date 2003-03-25 Time 07:30 Rev Time 0.30
Received By lsmith Date   Time   Sent To  
Notes
2003-03-25 00:00:00*******FAILED**********
  
 1. SUBMIT DETAIL FOR POOL EQUIPMENT
 ANCHORING.
 2. NEED TO ADD DETAIL FOR COMPLIANCE TO
 FBC 2001 CHAPTER 4 DETAILS FOR
 PROTECTION OF OPENINGS FROM THE HOUSE
 TO THE POOL.
  
 ADD THE ABOVE ITEMS TO THE PLANS &
 RESUBMIT.
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 805-6712

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-04-21 Cont ID  
Sent By btrobaug Date 2003-04-21 Time 16:11 Rev Time 0.50
Received By btrobaug Date 2003-04-21 Time 16:05 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2003-04-08 Cont ID  
Sent By shernand Date 2003-04-18 Time 15:29 Rev Time 0.33
Received By btrobaug Date 2003-04-08 Time 10:10 Sent To P
Notes
2003-04-16 00:00:00UNSAT
 ~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
  
 PLEASE NOTE THAT ALL PLANS
 DRAWN BY AN ARCHITECT/ENGINEER CONTAIN-
 ING A TITLE BLOCK, MUST BE SIGNED, DATED
 AND SEALED BY THE ARCH/ENGINEER OF
 RECORD. PER FS/FAC 481.221 & 471.025
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2003-03-25 Cont ID  
Sent By kstevens Date 2003-04-15 Time 14:21 Rev Time 0.50
Received By btrobaug Date 2003-03-25 Time 07:21 Sent To B
Notes
2003-03-25 00:00:00UNSAT
 ~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 THERE WAS NO ELECTRICAL SCHEMATIC,TYPE
 OF HEAT BEING USED,IF ANY,AND NO LOAD
 CALCS OR SERVICE SIZE SUBMITTED FOR
 REVIEW.
  
 PLEASE SUBMIT ALL THAT IS APPLICABLE.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/659-8096 EXT.8392

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-04-18 Cont ID  
Sent By shernand Date 2003-04-18 Time 15:29 Rev Time 0.00
Received By shernand Date 2003-04-18 Time 15:29 Sent To E
Notes
2003-04-18 00:00:00BT DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-04-04 Cont ID  
Sent By shernand Date 2003-04-04 Time 15:20 Rev Time 0.00
Received By shernand Date 2003-04-04 Time 15:20 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-03-25 Cont ID  
Sent By sthyng Date 2003-03-14 Time 15:57 Rev Time 0.00
Received By btrobaug Date 2003-03-14 Time 15:57 Sent To Z
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2003-04-15 Cont ID  
Sent By btrobaug Date 2003-04-16 Time 10:11 Rev Time 0.25
Received By kstevens Date 2003-04-15 Time 14:21 Sent To E
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2003-04-15 Cont ID  
Sent By kstevens Date 2003-04-15 Time 12:22 Rev Time 1.00
Received By kstevens Date 2003-04-15 Time 12:22 Sent To E
Notes
2003-04-15 00:00:00DENIED
  
  
 STATE REQUIREMENTS - CONTRACTOR SHALL BE
 EITHER CERTIFIED OR REGISTERED WITH THE
 STATE TO APPLY FOR PERMITS. SEE ATTACHED
 SHEET.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377
 (561) 805-6721
 FAX (561) 653-2692

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-03-24 Cont ID  
Sent By sgraham Date 2003-03-17 Time 10:06 Rev Time 0.50
Received By kstevens Date 2003-03-24 Time 07:21 Sent To E
Notes
2003-03-24 00:00:00DENIED
 REFERENCE: FBC-2001 424.2 SWIMMING POOLS
  
 A) PLEASE ADJUST YOUR NOTES, DETAILS, OR
 SUBMITTALS TO REFLECT THE FOLLOWING IN-
 FORMATION REQUIRED FOR PLAN REVIEW
 1) FBC-2001 SEC 424.2.6.1 ENGINEERING
 DESIGN, CONSTRUCTION AND WORKMANSHIP.
 ANSI/NSPI-4 92, AND NSPI-5. (ADD TO
 NOTES)
 2) FBC-2001424.2.6.6.2 SHOW COMPLIANCE
 WITH ANSI/ASME A112.19.8M. PROVIDE MODEL
 NUMBER AND MANUF INFO FOR VAC LOCK.
 (GIVE DETAIL OR ADD NOTE)(SUBMITTAL)
 3) FBC-2001 424.2.7.2 PUMPS AND EQUIP-
 MENT SHALL BE MOUNTED ON A SUBSTANTIAL
 BASE IN A MANNER THAT WILL ELIMINATE
 STRAIN ON PIPING. SLAB SHALL BE A NOMIN-
 AL 4" THICK. (DETAIL)
 4) INDICATE WHETHER OR NOT THERE IS A
 POOL HEATER. (NOT SHOWN ON POOL SPECS.)
 5) POOL PIPING SCHEMATIC SHOWS SPA DRAIN
 BUT NO SPA SHOWN ON POOL LAYOUT. PLEASE
 SUBMIT SCHEMATIC THAT REFLECTS POOL AS
 IT WILL BE BUILT.
 6) AN ENGINEERS TITLE BLOCK SHALL HAVE
 HIS NUMBER INCLUDED. 61G15-23.002(2)
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop Z ZONING
Rev No 1 Status P Date 2003-03-17 Cont ID  
Sent By btrobaug Date 2003-03-25 Time 07:38 Rev Time 0.00
Received By sgraham Date   Time   Sent To P
Notes
***NONE***