| Plan Review Stops For Permit 03031261 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2003-04-16 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2003-04-16 |
Time |
12:34 |
Rev Time |
0.75 |
| Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-03-25 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-03-25 |
Time |
07:30 |
Rev Time |
0.30 |
| Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-03-25 00:00:00 | *******FAILED********** | | | | | | 1. SUBMIT DETAIL FOR POOL EQUIPMENT | | | ANCHORING. | | | 2. NEED TO ADD DETAIL FOR COMPLIANCE TO | | | FBC 2001 CHAPTER 4 DETAILS FOR | | | PROTECTION OF OPENINGS FROM THE HOUSE | | | TO THE POOL. | | | | | | ADD THE ABOVE ITEMS TO THE PLANS & | | | RESUBMIT. | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 805-6712 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2003-04-21 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-04-21 |
Time |
16:11 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2003-04-21 |
Time |
16:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2003-04-08 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-18 |
Time |
15:29 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2003-04-08 |
Time |
10:10 |
Sent To |
P |
|
| Notes |
| 2003-04-16 00:00:00 | UNSAT | | | ~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | | | | PLEASE NOTE THAT ALL PLANS | | | DRAWN BY AN ARCHITECT/ENGINEER CONTAIN- | | | ING A TITLE BLOCK, MUST BE SIGNED, DATED | | | AND SEALED BY THE ARCH/ENGINEER OF | | | RECORD. PER FS/FAC 481.221 & 471.025 | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-03-25 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-04-15 |
Time |
14:21 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2003-03-25 |
Time |
07:21 |
Sent To |
B |
|
| Notes |
| 2003-03-25 00:00:00 | UNSAT | | | ~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | THERE WAS NO ELECTRICAL SCHEMATIC,TYPE | | | OF HEAT BEING USED,IF ANY,AND NO LOAD | | | CALCS OR SERVICE SIZE SUBMITTED FOR | | | REVIEW. | | | | | | PLEASE SUBMIT ALL THAT IS APPLICABLE. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/659-8096 EXT.8392 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-04-18 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-18 |
Time |
15:29 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-04-18 |
Time |
15:29 |
Sent To |
E |
|
| Notes |
| 2003-04-18 00:00:00 | BT DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-04-04 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-04 |
Time |
15:20 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-04-04 |
Time |
15:20 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-03-25 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-03-14 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2003-03-14 |
Time |
15:57 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2003-04-15 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-04-16 |
Time |
10:11 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2003-04-15 |
Time |
14:21 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2003-04-15 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-04-15 |
Time |
12:22 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2003-04-15 |
Time |
12:22 |
Sent To |
E |
|
| Notes |
| 2003-04-15 00:00:00 | DENIED | | | | | | | | | STATE REQUIREMENTS - CONTRACTOR SHALL BE | | | EITHER CERTIFIED OR REGISTERED WITH THE | | | STATE TO APPLY FOR PERMITS. SEE ATTACHED | | | SHEET. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 | | | (561) 805-6721 | | | FAX (561) 653-2692 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-03-24 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2003-03-17 |
Time |
10:06 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-03-24 |
Time |
07:21 |
Sent To |
E |
|
| Notes |
| 2003-03-24 00:00:00 | DENIED | | | REFERENCE: FBC-2001 424.2 SWIMMING POOLS | | | | | | A) PLEASE ADJUST YOUR NOTES, DETAILS, OR | | | SUBMITTALS TO REFLECT THE FOLLOWING IN- | | | FORMATION REQUIRED FOR PLAN REVIEW | | | 1) FBC-2001 SEC 424.2.6.1 ENGINEERING | | | DESIGN, CONSTRUCTION AND WORKMANSHIP. | | | ANSI/NSPI-4 92, AND NSPI-5. (ADD TO | | | NOTES) | | | 2) FBC-2001424.2.6.6.2 SHOW COMPLIANCE | | | WITH ANSI/ASME A112.19.8M. PROVIDE MODEL | | | NUMBER AND MANUF INFO FOR VAC LOCK. | | | (GIVE DETAIL OR ADD NOTE)(SUBMITTAL) | | | 3) FBC-2001 424.2.7.2 PUMPS AND EQUIP- | | | MENT SHALL BE MOUNTED ON A SUBSTANTIAL | | | BASE IN A MANNER THAT WILL ELIMINATE | | | STRAIN ON PIPING. SLAB SHALL BE A NOMIN- | | | AL 4" THICK. (DETAIL) | | | 4) INDICATE WHETHER OR NOT THERE IS A | | | POOL HEATER. (NOT SHOWN ON POOL SPECS.) | | | 5) POOL PIPING SCHEMATIC SHOWS SPA DRAIN | | | BUT NO SPA SHOWN ON POOL LAYOUT. PLEASE | | | SUBMIT SCHEMATIC THAT REFLECTS POOL AS | | | IT WILL BE BUILT. | | | 6) AN ENGINEERS TITLE BLOCK SHALL HAVE | | | HIS NUMBER INCLUDED. 61G15-23.002(2) | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-03-17 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-03-25 |
Time |
07:38 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
P |
|
| Notes |
|
|