Plan Review Details - Permit 03031106
Plan Review Stops For Permit 03031106
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2003-09-03 Cont ID  
Sent By mmclean Date 2003-09-03 Time 12:36 Rev Time 1.00
Received By sthyng Date 2003-08-29 Time 09:41 Sent To Z
Notes
2003-09-03 00:00:00REVISION TO ADD PORCH
2003-08-29 00:00:00DESIGNER BROUGHT IN PLANS BUT ORIGINAL
 APPLICATION IS STILL IN REVIEW.WILL
 BRING BACK AFTER REVIEWS FINISHED;
 ALREADY PAID FOR THE REVISION BUT NOT
 SUBMITTED YET

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2003-08-22 Cont ID  
Sent By sthyng Date 2003-08-22 Time 16:25 Rev Time 1.50
Received By sthyng Date 2003-08-22 Time 16:24 Sent To E
Notes
2003-08-22 00:00:00*****CORRECTIONS******
 REVISION TO ADD PORCH
  
 1.)SPECIFY ALL GIRDER CONNECTIONS.
  
 2.)SIMPSON CONNECTOR H16 IS NOT
 DESIGNED TO BE A TRUSS-TO-WOOD
 CONNECTION.DETAIL E, ATTACHMENT
 SPECIFIED HUSC410.DO YOU MEAN HUS410?
 TAP CONS SPECIFIED; NOT DESIGNED TO
 BE USED WITH BLOCK AS PER CATALOG.
 CHECK ALL CONNECTIONS.
  
 3.)HAVE AN ENGINEER CERTIFY THE
 STRUCTURAL DESIGN.
  
 4.)PROVIDE A NEW SITE PLAN FOR
 ZONING REVIEW.
  
 SAMANTHA THYNG, BUILDING PLANS EXAMINER
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-05-02 Cont ID  
Sent By csiegber Date 2003-08-22 Time 13:29 Rev Time 1.50
Received By sthyng Date 2003-05-02 Time 19:37 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-04-16 Cont ID  
Sent By pkrauss Date 2003-05-01 Time 14:25 Rev Time 4.00
Received By sthyng Date 2003-04-15 Time 19:41 Sent To  
Notes
2003-04-15 00:00:00**********CORRECTIONS************
  
 1.)A NOTICE OF COMMENCEMENT MUST BE
 RECORDED WITH THE CLERK OF COURTS BEFORE
 A PERMIT CAN BE ISSUED.
  
 2.)BEFORE A PERMIT TO CONSTRUCT MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.THIS MAY BE DONE AFTER THE
 FINAL REVIEW BUT BEFORE THE PERMIT CAN
 BE ISSUED.
  
 3.)BUILDING IS TO COMPLY WITH FBC
 3401.8.2.3.
  
 4.)PROVIDE PRODUCT APPROVALS FOR THE
 WINDOW MULLIONS AND THE MODIFIED ROOF.
  
 5.)THE FOLLOWING WINDOWS APPEAR TO BE
 IN HAZARDOUS LOCATIONS PER FBC2405.2:
 NEW BATHROOM
 NEW WINDOW, REAR ELEVATION
 EXISTING WINDOWS, LEFT ELEVATION
  
 6.)PLEASE CLARIFY - THE SIMPSON H16 IN
 DETAIL B DOES NOT APPEAR TO BE ABLE TO
 BE ATTACHED TO THE BEAM ON ONE SIDE DUE
 TO THE POSITION OF THE EXISTING TRUSS.
  
 7.)PROVIDE A DETAIL FOR THE HEADER AT
 THE NEW FRONT PORCH.
  
 8.) ATTIC ACCESS REQUIRED PER FBC2309.6.
  
 9.)DRAFTSTOPPING REQUIRED FBC 705.3.2.
  
 10.) ADDITIONAL FEES REQUIRED; MAY BE
 PAID WHEN THE PERMIT IS PICKED UP.
  
 WHEN RESUBMITTING PLANS PLEASE CLEARLY
 INDICATE THE REVISION AND REMOVE AND
 REPLACE ANY PAGES AS NECESSARY.SUBMIT
 ONE SET OF OLD DRAWINGS WITH
 THE PLANS WHEN RESUBMITTING PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN
 BE FOUND, WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 SAMANTHA THYNG, BUILDING PLANS EXAMINER
 [email protected]

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2004-12-07 Cont ID  
Sent By btrobaug Date 2004-12-07 Time 09:47 Rev Time 0.50
Received By btrobaug Date 2004-12-08 Time 13:02 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2004-10-21 Cont ID  
Sent By mjacobs Date 2004-12-03 Time 16:48 Rev Time 0.00
Received By btrobaug Date 2004-10-21 Time 14:53 Sent To P
Notes
2004-10-21 00:00:00 
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} THE RISER DIAGRAM SHOWS A METER AND
 ASEPARATE DISCONNECT. THE PLAN
 INDICATES A METER MAIN COMBINATION,
 PLEASE
 CLARIFY.
  
 2} THE FEED FROM THE DISCONNECT (IF
 THERE IS ONE) TO THE PANEL NEEDS A
 GROUND PER 250.122.
  
 3} THE KITCHEN RECEPTACLE CIRCUITS MUST
 COMPLY WITH 210.11(C)(1). THERE MUST BE
 A MINIMUM OF 2@1500 VA, AND THE LIVING
 ROOM MAY NOT BE ON EITHER CIRCUIT. SEE
 210.52(B) FOR WHAT IS ALLOWED. PLEASE
 MAKE NECESSARY CHANGES TO THE PANEL
 SCHEDULE.
  
 4} THE LAUNDRY CIRCUITS MUST COMPLY
 WITH220.16(B). THIS CIRCUIT WAS REMOVED
 FROM THE SCHEDULE. IF USING THE LABEL
 "WASHER" TO INDICATE THE LAUNDRY
 CIRCUIT IT MUST BE CALCULATED @ 1500VA.
  
 5} THE BATH GFI MUST COMPLY WITH 210.11
 (C)(3), 20 AMP, # 12.SEE SCHEDULE LISTS
 SAME AT 15 AMP #14.
  
 6} PLEASE SEE THAT ALL KITCHEN
 COUNTERTOP RECEPTACLES MUST COMPLY WITH
 210.11(C)(1), 210.8(A)(6), AND
 210.52(C).
  
 7} PLEASE SEE CIRCUIT #20, SHED? REFER
 ON PLAN.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-08-27 Cont ID  
Sent By btrobaug Date 2003-08-27 Time 13:03 Rev Time 0.50
Received By btrobaug Date 2003-08-27 Time 12:36 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-04-29 Cont ID  
Sent By sthyng Date 2003-08-22 Time 16:31 Rev Time 0.50
Received By btrobaug Date 2003-04-29 Time 16:09 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2003-03-18 Cont ID  
Sent By shernand Date 2003-04-28 Time 14:14 Rev Time 0.75
Received By btrobaug Date 2003-03-18 Time 15:26 Sent To P
Notes
2003-03-18 00:00:00UNSAT
 ~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 PLEASE NOTE THE SERVICE IS TO SMALL FOR
 FOR THE ADDITIONAL LOAD.
 SUBMIT A RISER DIAGRAM WITH FEEDER SIZES
 AND GROUNDING DETAILS.SEE 215-5.
  
 THE LAUNDRY CIRCUIT IS REQUIRED TO BE 20
 AMP PER 210-11(C)(2).
  
 THE GARAGE NEEDS A GFI PER 210-8(A)(1).
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/659-8096

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-12-03 Cont ID  
Sent By mjacobs Date 2004-12-03 Time 16:48 Rev Time 0.00
Received By mjacobs Date 2004-12-03 Time 16:48 Sent To E
Notes
2004-12-03 00:00:00SENT TO "BT" DESK.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-08-22 Cont ID  
Sent By csiegber Date 2003-08-22 Time 13:28 Rev Time 0.00
Received By csiegber Date 2003-08-22 Time 13:28 Sent To B
Notes
2003-08-22 00:00:00TO ST DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-04-28 Cont ID  
Sent By shernand Date 2003-04-28 Time 14:13 Rev Time 0.00
Received By shernand Date 2003-04-28 Time 14:13 Sent To E
Notes
2003-04-28 00:00:00BT DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-03-14 Cont ID  
Sent By sthyng Date 2003-03-14 Time 13:47 Rev Time 0.00
Received By sthyng Date 2003-03-14 Time 13:47 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-05-01 Cont ID  
Sent By pkrauss Date 2003-05-01 Time 14:24 Rev Time 0.30
Received By pkrauss Date 2003-05-01 Time 14:16 Sent To B
Notes
2003-05-01 00:00:00MECHANICAL PERMIT 03031109

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2003-03-26 Cont ID  
Sent By kstevens Date 2003-04-30 Time 14:33 Rev Time 0.35
Received By pkrauss Date 2003-03-26 Time 12:55 Sent To B
Notes
2003-03-26 00:00:00PROVIDE EQUIPMENT SIZING (MANUAL J)
 AS PER 2001 FBC CHAPTER 13 SECTION
 607.1.ABC.1.PROVIDE THE ABOVE
 INFORMATION WITH MECHANICAL PERMIT
 APPLICATION.
  
 ENERGY CALCS SUBMITTED WITH BUILDING
 PERMIT.NO MECHANICAL PLANS SUBMITTED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop P PLUMBING
Rev No 4 Status P Date 2004-10-23 Cont ID  
Sent By pschmitz Date 2004-10-23 Time 13:28 Rev Time 0.00
Received By pschmitz Date   Time   Sent To  
Notes
2004-10-23 00:00:00REVISION APPROVED.PES

Review Stop P PLUMBING
Rev No 3 Status P Date 2003-09-02 Cont ID  
Sent By btrobaug Date 2004-10-21 Time 12:55 Rev Time 0.33
Received By kstevens Date 2003-09-02 Time 13:12 Sent To  
Notes
2003-09-02 00:00:00REVISION - NO CHANGE

Review Stop P PLUMBING
Rev No 2 Status P Date 2003-04-30 Cont ID  
Sent By btrobaug Date 2003-08-27 Time 13:04 Rev Time 0.25
Received By kstevens Date 2003-04-30 Time 14:27 Sent To M
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-03-24 Cont ID  
Sent By btrobaug Date 2003-04-29 Time 16:35 Rev Time 0.33
Received By kstevens Date 2003-03-24 Time 06:19 Sent To M
Notes
2003-03-24 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1) ONLY THE FIXTURES WITHIN THE BATHROOM
 GROUP SHALL CONNECT TO THE WET-VENTED
 HORIZONTAL BRANCH DRAIN. SECTION 909.1
 THE WASH MACHINE SHALL CONNECT DOWN-
 STREAM OF THE BATHROOM GROUP.
 2) SHT 4 0F 4 SHOWER LABLED SINK, AND
 MINIMUM SIZE OF PIPE UNDER SLAB AND FOR
 SHOWER IS 2". 1-1/4" SHOWN.
 3) SHT 4 OF 4 NOTE #1 CODE SHALL READ
 FBC-2001 PLUMBING, NOT NATIONAL PLUMBING
 CODE.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop Z ZONING
Rev No 2 Status P Date 2003-09-03 Cont ID  
Sent By mmclean Date 2003-09-03 Time 12:36 Rev Time 0.00
Received By mmclean Date   Time   Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-03-18 Cont ID  
Sent By sthyng Date 2003-09-03 Time 11:05 Rev Time 0.00
Received By btrobaug Date 2003-03-17 Time 08:35 Sent To E
Notes
***NONE***