| Plan Review Stops For Permit 03031105 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2003-07-10 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-07-10 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-07-10 |
Time |
14:15 |
Sent To |
FIRE |
|
| Notes |
| 2003-07-10 00:00:00 | PAY IMPACT FEES TO COUNTY |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2003-05-29 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-05-29 |
Time |
15:51 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-05-29 |
Time |
12:47 |
Sent To |
|
|
| Notes |
| 2003-05-29 00:00:00 | THE DELTA FIRE SPRINKLER PLANS DO NOT | | | HAVE COMPLETE DESIGN INFORMATION AND | | | WERE NOT PREPARED BY AN ENGINEER.SEE | | | FBC 104.2 AND THE FL ADMINISTRATIVE | | | CODE CHAPTERS 61G15-31 AND 61G15-32. | | | | | | THE PLANS DO NOT SHOW THE DRAFTSTOPPING | | | IN THE EXTERIOR WOOD TRUSS CANOPY IN | | | ACCORDANCE WITH FBC 2305.2.4. | | | | | | THE HORTON AUTOMATIC NOA 03-0306.05 IS | | | MISSING PAGES.NOA 00-0512.12 IS | | | EXPIRED AND ILLEGIBLE. | | | | | | THE SW FLEMING NOA 97-0327.01 IS | | | EXPIREDNOA 01-0129.09 IS MISSING PAGES | | | AND IS ILLEGIBLE. | | | | | | NOA 00-0508.01 HAS THE WRONG DRAWINGS | | | ATTACHED TO IT. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-04-15 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-04-15 |
Time |
09:21 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-04-14 |
Time |
15:04 |
Sent To |
Z |
|
| Notes |
| 2003-04-15 00:00:00 | THE FIRE SPRINKLER PROTECTION PLANS ARE | | | REQUIRED TO BE INCLUDED WITH THE | | | BUILDING PERMIT PLANS. SEE FBC | | | 140.3.1.1 #5. | | | | | | IF TEST AND OR NOTICE OF ACCEPTANCE | | | REPORTS FOR THE DOORS WINDOWS AND ROOF | | | COVERING ARE NOT INCLUDED WITH THIS | | | PERMIT APPLICATION, A SEPARATE PERMIT | | | AND FEES WILL BE REQUIRED. | | | | | | BEFORE A PERMIT TO CONSTRUCT MAY BE | | | ISSUED IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, THE PERMIT PLANS STAMPED | | | BY THAT OFFICE AND A COPY OF THE PAID | | | RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION.CALL (561) 233-5025 FOR | | | MORE INFORMATION. | | | | | | THE EXTERIOR CANOPY/CORNICE REQUIRES | | | DRAFTSTOPPING IN ACCORDANCE WITH FBC | | | 2305.4. | | | | | | THE FOAM BASED ARCHITECTURAL TRIM SHOWN | | | IN SECTION 2/A2.2 IS PROHIBITTED BY FBC | | | F102.2.7 AS AMENDED BY THE CITY. | | | (NON-COMBUSTIBLE MATERIAL OR FRT LUMBER | | | IS REQUIRED.) |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2003-07-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-07-09 |
Time |
17:33 |
Rev Time |
1.50 |
| Received By |
dpalmer |
Date |
2003-07-09 |
Time |
17:32 |
Sent To |
|
|
| Notes |
| 2003-07-09 00:00:00 | ********** NOTES REDLINED ********* | | | | | | PLEASE SEE NOTE REDLINED ON RISER | | | DIAGRAM. NO MORE THAN 8' OF UNPROTECTED | | | CONDUCTOR INSIDE BLDG PER LOCAL | | | AMENDMENTS 210-70 | | | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS | | | FROM SETS. | | | | | | MDP PANEL SCHEDULEON E-11 STILL SHOWS | | | MLO. | | | | | | PLEASE REVISE PLANS BEFORE ROUGH | | | ELECTRICAL INSPECTION IS CALLED IN. | | | | | | IF THERE ARE ANY QUESTINOS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2003-05-30 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-05-30 |
Time |
14:44 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2003-05-30 |
Time |
12:36 |
Sent To |
|
|
| Notes |
| 2003-05-30 00:00:00 | UNSAT | | | ~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | PLEASE NOTE THE FOLLOWING COMMENTS FROM | | | THE LAST REVIEW THAT WERE ONLY | | | PARTIALLY ADDRESSED OR NOT | | | SATIFACTORILY ADDRESSED. | | | | | | 1} THE PANEL SCHEDULES ARE STILL LISTING | | | MLO & MAIN,AND NOW PANELS "C" & "P" | | | LIST MCB.IF THE PANEL RATING IN AMPS IS | | | 225 OR 100,IT SHOULD NOT BE LISTED AS | | | IF THAT WERE THE MAIN BREAKER | | | SIZE.PLEASE CLARIFY ALL PANEL | | | DESIGNATIONS WITH CONSISTENCY. | | | | | | 2} THERE ARE STILL SEVERAL EXIT & | | | EMERGENCY LIGHTS ON CIRCUIT A-20(SHEET | | | E-2). THIS IS IN VIOLATION OF ARTICLE | | | 700-12(E). | | | | | | PLEASE CORRECT AND RESUBMIT FOR REVIEW. | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-03-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-03-24 |
Time |
09:11 |
Rev Time |
2.00 |
| Received By |
dpalmer |
Date |
2003-03-24 |
Time |
09:11 |
Sent To |
|
|
| Notes |
| 2003-03-24 00:00:00 | ************* UNSAT ******************** | | | | | | | | | 1)NOTE: PLEASE SEE GENERAL NOTE FOR | | | AIC RATINGS. IT IS NOTED THAT "PANELS" | | | ARE TO BE 65K SERIES RATED, PLEASE | | | CLARIFY IF THIS IF FOR MAIN DISC ALSO.? | | | 110-9 | | | | | | 2)NOTE: PLEASE CORRELATE RISER DIAGRAM | | | AND PANEL SCHEDULES. PLEASE SEE RISER | | | SHOWS PANELS "C" AND "P" AS 225A AND | | | PANEL SCHEDULES SHOW THEM AS 100A. | | | PLEASE ALSO CLARIFY PANELS. THEY ARE | | | ALL SHOWN AS MLO AND MCB? P RISER SHOWS | | | PANELS AS BEING MLO.? | | | | | | 3)NOTE: PLEASE SHOW CIRCUITING FOR | | | EM/EXT LTS PER 700-12E | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2003-06-26 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2003-06-26 |
Time |
15:45 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2003-06-26 |
Time |
15:45 |
Sent To |
|
|
| Notes |
| 2003-06-26 00:00:00 | PASSED : | | | 1. SEE PERMIT # 03061900 FOR UNDERGROUND | | | UTILITIES AND SITE WORKS. | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2003-03-19 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2003-03-19 |
Time |
14:13 |
Rev Time |
2.00 |
| Received By |
mamini |
Date |
2003-03-19 |
Time |
14:13 |
Sent To |
|
|
| Notes |
| 2003-03-19 00:00:00 | FAILED: | | | 1. CURB CUT RAMP MUST BE INSTALLED ON | | | MAIN APPROACH AT PALM BEACH LAKES BLVD. | | | 2. MAIN APPROACH; FROM DROP CURB TO THE | | | PROPERTY LINE MUST BE CONSTRUCTED USING | | | 6" CONCRETE. | | | 3.ALL BROKEN SIDEWALK ALONG THE PROPERTY | | | (ALL SIDE) MUST BE REPLACED. | | | 4. ALL DRIVE APPROACH MUST BE AT MINIMUM | | | PER CITY STANDARD. | | | 5. ALL THE EASEMENTS AS SHOWN MUST BE | | | RECORDED IN PUBLIC RECORDS OF PALM BEACH | | | COUNTY. | | | 6. PARKING STALLS MUST BE PAINTED WITH | | | DOUBLE 4" WIDE WHITE FOR REGULAR SPACES. | | | 7. PLEASE SUBMIT TWO COPIES OF CIVIL/ | | | SITE PLANS TO PUBLIC UTILITIES | | | ENGINEERING SERVICES FOR THEIR REVIEW | | | AND APPROVAL OF ALL THE CONNECTIONS TO | | | CITY SERVICES AND FOR THE LOCATION OF | | | BACKFLOWS,METERS, ETC.. | | | 8. PLEASE PROVIDE STORM WATER CALC. AND | | | A COPY OF SFWMD PERMIT FOR OUR REVIEW | | | AND APPROVAL, SUBMITTALS MUST INCLUDE | | | PERVIOUS AND IMPERVIOUS CALC. FOR TOTAL | | | SITE AREA. | | | 9. PLEASE NOTE THAT A SEPARATE PERMIT | | | APPLICATION AND FEES FOR UNDERGROUND | | | UTILITIES AND SITE WORK WILL BE REQUIRED | | | IF ANY QUESTION PLEASE CONTACT 659-8096 | | | EXT. 8492 MOHAMMAD R. AMINI |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2003-07-11 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-07-11 |
Time |
07:27 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-07-11 |
Time |
07:27 |
Sent To |
|
|
| Notes |
| 2003-07-11 00:00:00 | 1) ON JULY 10, 2003, WRITER CONTACTED | | | THE ARCHITECT KENT HAMILTON BY PHONE | | | TO DISCUSS THE PLANS. HE ADVISED WHERE | | | THE CORRECTIONS COULD BE LOCATED SINCE | | | THE RESUBMITTED PLANS WERE DIFFICULT TO | | | FOLLOW. THE FOLLOWING ITEMS COULD NOT | | | BE LOCATED OR REVIEWED. | | | | | | A) ITEM # 9 FROM PREVIOUS COMMENTS. | | | HOW DOES THE MONUMENT SIGN NOT | | | INTERFERE WITH ACCESS TO THE PROPOSED | | | FIRE HYDRANT. | | | | | | B) ITEM # 2 FROM PREVIOUS COMMENTS. | | | ELECTRONIC SWITCHES ARE REQUIRED FOR | | | THE FIRE LINE BACKFLOW DEVICE. | | | | | | C) ACCORDING TO MR. HAMILTON, NO | | | SECURITY DEVICES WILL NOT INTERFERE | | | WITH EGRESS FROM BUILDING. MR. | | | HAMILTON, ALL EGRESS DOORS EXCEPT | | | THE MAIN DOORS WILL BE EQUIPPED WITH | | | PANIC HARDARE AND WILL HAVE FREE | | | EGRESS AT ALL TIMES. | | | | | | APPROVED PROVISO: | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-07-10 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2003-06-24 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-06-24 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-06-24 |
Time |
14:53 |
Sent To |
|
|
| Notes |
| 2003-06-24 00:00:00 | *************DENIED******************** | | | PLEASE NOTE THE PREVIOUS COMMENTS FROM | | | THE LAST REVIEW WERE ONLY PARTIALLY | | | ADDRESSED OR NOT ADDRESSED. | | | | | | FIRE SPRINKLER PLANS DO NOT HAVE | | | COMPLETE DESIGN INFORMATION AND FLOW | | | DATA. AND THE PLANS ARE NOT SEALED. | | | | | | NATE MCCRAY, CAPTAIN | | | 805-6722 OR 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2003-04-04 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-04-04 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-04-04 |
Time |
14:40 |
Sent To |
|
|
| Notes |
| 2003-04-04 00:00:00 | 1) THE BUILDING IS LOCATED IN THE | | | CITY FIRE LIMITS. CERTAIN RESTRICTIONS | | | APPLY. PLEASE SEE APPENDIX F, LOCAL | | | AMENDMENTS TO THE FLORIDA BUILDING | | | CODE. | | | | | | 2) ELECTRONIC SWITCHES ARE REQUIRED | | | ON THE FIRE LINE BACKFLOW DEVICE. | | | | | | 3) THE AUTOMATIC DOORS SHALL COMPLY | | | WITH NFPA 101, THE LIFE SAFETY CODE, | | | 2000 EDITION, SECTION 7. | | | | | | 4) PLEASE OBTAIN YOUR KNOX-BOX | | | APPLICATION FROM THIS OFFICE SO YOU | | | CAN ODER IT. | | | | | | 5) WOOD NOTED ON EXTERIOR. AGAIN | | | CERTAIN RESTRICTIONS APPLY IN THE | | | FIRE LIMITS. | | | | | | 6) THE BUILDING ADDRESS IS REQUIRED | | | ON THE PROPER ELEVATION. | | | | | | 7) PLEASE PROVIDE PRESCRIPTIVE CODE | | | REQUIREMENTS FOR HANDRAILS. | | | | | | 8) HOW DOES THE MONUMENT SIGN NOT | | | INTERFERE WITH ACCESS TO THE PROPOSED | | | FIRE HYDRANT. | | | | | | 9) SECURITY DEVICES INSTALLED SHALL | | | NOT INTERFERE WITH ANY EGRESS FROM | | | THE BUILDING. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2003-10-31 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2003-10-31 |
Time |
09:40 |
Rev Time |
0.00 |
| Received By |
lsmith |
Date |
2003-10-31 |
Time |
09:40 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2003-10-06 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-06 |
Time |
12:13 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-06 |
Time |
12:13 |
Sent To |
P |
|
| Notes |
| 2003-10-06 00:00:00 | TO KS BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-08-04 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-08-04 |
Time |
16:20 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2003-08-04 |
Time |
16:20 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-05-22 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2003-07-14 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-22 |
Time |
09:43 |
Sent To |
|
|
| Notes |
| 2003-05-22 00:00:00 | COMM BOARD #38 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-03-14 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-03-14 |
Time |
10:50 |
Rev Time |
0.00 |
| Received By |
sthyng |
Date |
2003-03-14 |
Time |
10:50 |
Sent To |
|
|
| Notes |
| 2003-03-14 00:00:00 | COMM BOARD #59 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2003-04-10 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-04-10 |
Time |
11:46 |
Rev Time |
1.40 |
| Received By |
pkrauss |
Date |
2003-04-10 |
Time |
11:46 |
Sent To |
|
|
| Notes |
| 2003-04-10 00:00:00 | MECHANICAL PERMIT REQUIRED - PROVIDE | | | MANUFACTURER INSTALLATION INSTRUCTIONS | | | FOR THE FIRE DAMPER ON THE JOBSITE AT | | | TIME OF INSPECTION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
P |
Date |
2003-11-01 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-11-01 |
Time |
12:06 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-11-01 |
Time |
12:06 |
Sent To |
|
|
| Notes |
| 2003-11-01 00:00:00 | CONNECTING DOWNSPOUTS TO STORM AND TIE | | | TO CATCH BASIN. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
F |
Date |
2003-10-17 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2003-10-31 |
Time |
09:40 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-10-17 |
Time |
18:36 |
Sent To |
|
|
| Notes |
| 2003-10-17 00:00:00 | DENIED | | | REFERENCE: FBC-2001 CHAPTER 1 | | | | | | 1) REVISIONS SHALL HAVE CLARITY, AND | | | CONTRAST, ALL REVISED SECTIONS OF PLANS | | | SHALL BE INDICATED BY THE USE OF CLOUDS | | | ECT. UNABLE TO DETERMINE THE REVISION | | | BEING SUBMITTED. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2003-07-11 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-06 |
Time |
12:18 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2003-07-11 |
Time |
14:01 |
Sent To |
|
|
| Notes |
| 2003-07-11 00:00:00 | PASSED/PROVISO | | | | | | FILLMASTER FILTER NOT APPROVED. FILTER | | | SHALL BE NSP APPROVED AND LABELED PER | | | SECTION 303.4 - WILL SUBMIT MODEL THAT | | | IS LABELED PRIOR TO ROUGH INSPECTION. | | | | | | WATER HAMMER ARRESTORS SHALL BE LOCATED | | | NEAR THE FIXTURE IN AN "EFFECTIVE RANGE" | | | NOT IN CEILING. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2003-07-10 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-07-10 |
Time |
12:11 |
Rev Time |
1.50 |
| Received By |
kstevens |
Date |
2003-07-10 |
Time |
12:11 |
Sent To |
|
|
| Notes |
| 2003-07-10 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 11 | | | | | | FOLLOWING COMMENTS NOT ADDRESSED FROM | | | PREVIOUS REVIEW. FOR CLAIRTY THE COMMENT | | | NUMBER FROM FIRST REVIEW WILL BE USED. | | | | | | 4) SHT P-1 #13 FILTER SHALL COMPLY WITH | | | NSF STANDARD. MANUF. INFO REQUIRED. - | | | INFORMATION RECIEVED AND NSF LISTING NOT | | | SHOWN. CHECKED NSF RECORDS AND NO LIST- | | | ING SHOWN FOR THIS PRODUCT. SEC 303.4 | | | 7) (IN PART) WATER HAMMER ARRESTORS REQ- | | | UIRED BY SEC 406.9 SHALL BE LOCATED NEAR | | | THE FIXTURE IN AN "EFFECTIVE RANGE", NOT | | | IN THE CEILING AT THE TOP OF THE DROP. | | | PDI-WH 201 AND MANUFACTURE INSTALLATION | | | INSTRUCTIONS. | | | | | | NEW COMMENT: SEE ATTACHED SHEET CONCERN- | | | ING FLORIDA STATUTE 553.80(2)(B) | | | | | | *********WHEN RESUBMITTING PLANS******** | | | PLEASE CLEARLY INDICATE THE REVISION AND | | | REMOVE AND REPLACE ANY PAGES AS NECESS- | | | ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH | | | THE PLANS WHEN RESUBMITTING PLANS. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN | | | BE FOUND, WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2003-06-14 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-06-14 |
Time |
14:03 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-06-14 |
Time |
14:03 |
Sent To |
|
|
| Notes |
| 2003-06-14 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 11 | | | | | | FOLLOWING COMMENTS NOT ADDRESSED FROM | | | PRIVIOUS REVIEW. FOR CLAIRTY THE COMMENT | | | NUMBER FROM FIRST REVIEW WILL BE USED. | | | | | | 4) SHT P-1, #13 FILTER SHALL COMPLY WITH | | | NSF STANDARD. MANUF. INFO REQUIRED. | | | 7) (IN PART) WATER HAMMER ARRESTORS REQ- | | | UIRED BY SEC 406.9 SHALL BE LOCATED NEAR | | | THE FIXTURE IN AN "EFFICTIVE RANGE" NOT | | | IN THE CEILING AT THE TOP OF THE DROP. | | | PDI-WH 201 & MANUF. INSTALLATION | | | INSTRUCTIONS. | | | | | | NEW COMMENT. | | | *********WHEN RESUBMITTING PLANS******** | | | PLEASE CLEARLY INDICATE THE REVISION AND | | | REMOVE AND REPLACE ANY PAGES AS NECESS- | | | ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH | | | THE PLANS WHEN RESUBMITTING PLANS. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN | | | BE FOUND, WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-03-28 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-03-28 |
Time |
12:49 |
Rev Time |
2.75 |
| Received By |
kstevens |
Date |
2003-03-28 |
Time |
10:17 |
Sent To |
|
|
| Notes |
| 2003-03-28 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 11 | | | | | | 1) SHT A2.2 PROVIDE CALCULATIONS FOR | | | PRIMARY AND SECONDARY ROOF DRAINS PER | | | SEC'S 1106 & 1107. SHOW 1/2 AREA OF ALL | | | VERTICAL WALLS, (1106.4), INCLUDING | | | PARAPET, (1106.5). SHOW AREA OF ROOFS | | | THAT DRAIN ON TO ROOF FROM ABOVE. | | | INDICATE SQUARE FOOTAGE DRAINED BY EACH. | | | 2) SHT 2.2 INDICATE PITCH OF GUTTERS PER | | | TABLE 1106.6 AND SHOW SQUARE FOOTAGE | | | DRAINED FROM EACH ROOF AREA TO GUTTER. | | | 3) SHT A2.2 INDICATES 24"X16" SCUPPERS | | | AND OVERFLOW SCUPPERS. IT SAYS TYPICAL | | | OF 5, BUT ONLY 4 ARE SHOWN. PLEASE | | | CLAIRFY. | | | 4) SHT P-1 #13 FILTER SHALL COMPLY WITH | | | NSF STANDARD. MANUF. INFO. REQUIRED. | | | 5) SHT P-1 #'S 15 & 19, FLOOR DRAINS ARE | | | NOT APPROVED FOR INDIRECT WASTE. ALL | | | INDIRECT WASTE SHALL DRAIN TO FLOOR SINK | | | SECTION 802.3 | | | 6) SHT P-3 DETAILS #3 & 6, FLOOR SINKS | | | REQUIRED. SECTION 802.3 | | | 7) SHT P-4 WATER RISER DIAGRAM, AIR | | | CHAMBERS ARE NOT APPROVED. WATER HAMMER | | | ARRESTORS REQUIRED BY 406.9, (AT QUICK | | | CLOSING VALVES), SHALL BE LOCATED NEAR | | | THE FIXTURE IN AN "EFFECTIVE RANGE" NOT | | | AT THE TOP OF THE DROP IN THE CEILING. | | | PDI-WH 201 & MANUF. INSTALLATION INSTR. | | | 8) IRRIGATION PERMIT REQUIRED. PLUMBING | | | CONTRACTOR SHALL TIE INTO WATER SERVICE | | | AND SUPPLY SHUT OFF VALVE FOR IRRIGATION | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2003-08-07 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2003-08-07 |
Time |
09:57 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2003-07-14 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-08-04 |
Time |
16:20 |
Rev Time |
1.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
I |
|
| Notes |
| 2003-06-10 00:00:00 | 6/10/03 PASS ZONING, GIVEN TO SYLVIA MM |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2003-05-23 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-04-15 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-05-23 00:00:00 | DENIED, APPROVED SITE MUST BE SUBMITTED |
|
|