| Plan Review Stops For Permit 03031049 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2003-04-17 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-07-31 |
Time |
09:30 |
Rev Time |
3.00 |
| Received By |
lhatten |
Date |
2003-04-13 |
Time |
19:22 |
Sent To |
|
|
| Notes |
| 2003-04-17 00:00:00 | REVIEW & STAMPED PLANS 04/13/2003 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2004-03-27 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-03-27 |
Time |
10:06 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-03-27 |
Time |
10:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2003-04-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-04-29 |
Time |
08:50 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-04-29 |
Time |
08:50 |
Sent To |
P |
|
| Notes |
| 2003-04-29 00:00:00 | ******** NOTE REDLINED ********** | | | | | | GROUNDING ELECTRODE CONDUCTOR STILL | | | SHOWN AS WRONG SIZE.NEEDS #2. | | | 250-66/310-15B6 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-03-28 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-28 |
Time |
14:00 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2003-03-28 |
Time |
07:16 |
Sent To |
P |
|
| Notes |
| 2003-03-28 00:00:00 | ************* UNSAT ****************** | | | | | | 1)NOTE: PLEASE SIZE GROUNDING ELECTRODE | | | CONDUCTOR PER 250-66, BASED ON MIN SEC`S | | | FROM 310-15. | | | | | | 2)NOTE: PLEASE CORRELATE PANEL WITH | | | RISER DIAGRM. PANELS SHOWN AS 150A AND | | | RISER SHOWS AS 200A`S?? | | | | | | 3)NOTE: PLEASE SEE 220-16B FOR MIN SIZE | | | FOR WASHER CIRCUIT. | | | | | | 4)NOTE: SD NOT PERMITTED IN KITCHEN PER | | | NFPA-72 8-1.4.2 | | | | | | 5)NOTE: PLEASE SEE MISSING EQUIPMENT | | | GROUNDING CONDUCTOR BETWEEN MAIN DISC | | | AND PANEL "B", SIZE PER 250-122 | | | | | | 6)NOTE: PLEASE LIST THE REQ`D BATH | | | CIRCUIT(S) PER 210-52D/210-11-C3 | | | | | | 7)NOTE:PLEASE SHOW LOCATION OF PANEL B. | | | | | | 8)NOTE: PLAN SHOWS TWO SD`S IN MASTER | | | BEDROOM. PLEASE NOTE, TWO MAY BE | | | INSTALLED, HOWEVER AN ADDITIONAL SD | | | NEEDS TO BE OUTSIDE BR. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-07-31 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-07-31 |
Time |
09:30 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2003-07-31 |
Time |
09:30 |
Sent To |
B |
|
| Notes |
| 2003-07-31 00:00:00 | TO LHATTEN DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-07-24 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-07-24 |
Time |
14:07 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2003-07-24 |
Time |
14:07 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-04-28 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-28 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-04-28 |
Time |
13:59 |
Sent To |
E |
|
| Notes |
| 2003-04-28 00:00:00 | DP DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-03-14 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-03-14 |
Time |
13:14 |
Rev Time |
0.00 |
| Received By |
sthyng |
Date |
2003-03-14 |
Time |
13:14 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2003-04-03 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2003-03-31 |
Time |
18:26 |
Rev Time |
0.25 |
| Received By |
hmoser |
Date |
2003-04-03 |
Time |
19:04 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2003-07-29 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-07-29 |
Time |
14:14 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-07-29 |
Time |
14:13 |
Sent To |
|
|
| Notes |
| 2003-07-29 00:00:00 | PASSED/PROVISO | | | | | | SHT A-3 FLOOR PLAN NEEDS REVISION TO RE- | | | FLECT SANT. RISER DIAGRAM. NEW BAR SINK | | | ADDED TO RISER. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2003-04-30 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-07-24 |
Time |
14:08 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2003-04-30 |
Time |
15:18 |
Sent To |
B |
|
| Notes |
| 2003-04-30 00:00:00 | PASSED/PROVISO | | | | | | REVISION REQUIRED - EXTRA LAV ON RISER |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-03-31 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-04-29 |
Time |
08:50 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2003-03-31 |
Time |
18:26 |
Sent To |
M |
|
| Notes |
| 2003-03-31 00:00:00 | DENIED; | | | PAGE A-1 PLUMBING RISER DIAGRAM NOT TO | | | CODE. SEC. 909.1. WET VENTS FOR BATH- | | | ROOMS ARE PERMITTED TO VENT ONLY BATH- | | | ROOM FIXTURES. WASHING MACHINE AND | | | LAUNDRY TUB ARE REQUIRED TO DISCHARGE | | | DOWN STREAM OF THE BATHROOM GROUP. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 659-8096 EXT. 8369 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-03-17 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-03-14 |
Time |
13:14 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
E |
|
| Notes |
|
|