Plan Review Details - Permit 03031049
Plan Review Stops For Permit 03031049
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2003-04-17 Cont ID  
Sent By alange Date 2003-07-31 Time 09:30 Rev Time 3.00
Received By lhatten Date 2003-04-13 Time 19:22 Sent To  
Notes
2003-04-17 00:00:00REVIEW & STAMPED PLANS 04/13/2003

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2004-03-27 Cont ID  
Sent By btrobaug Date 2004-03-27 Time 10:06 Rev Time 0.50
Received By btrobaug Date 2004-03-27 Time 10:06 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-04-29 Cont ID  
Sent By dpalmer Date 2003-04-29 Time 08:50 Rev Time 0.50
Received By dpalmer Date 2003-04-29 Time 08:50 Sent To P
Notes
2003-04-29 00:00:00******** NOTE REDLINED **********
  
 GROUNDING ELECTRODE CONDUCTOR STILL
 SHOWN AS WRONG SIZE.NEEDS #2.
 250-66/310-15B6

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2003-03-28 Cont ID  
Sent By shernand Date 2003-04-28 Time 14:00 Rev Time 0.33
Received By dpalmer Date 2003-03-28 Time 07:16 Sent To P
Notes
2003-03-28 00:00:00************* UNSAT ******************
  
 1)NOTE: PLEASE SIZE GROUNDING ELECTRODE
 CONDUCTOR PER 250-66, BASED ON MIN SEC`S
 FROM 310-15.
  
 2)NOTE: PLEASE CORRELATE PANEL WITH
 RISER DIAGRM. PANELS SHOWN AS 150A AND
 RISER SHOWS AS 200A`S??
  
 3)NOTE: PLEASE SEE 220-16B FOR MIN SIZE
 FOR WASHER CIRCUIT.
  
 4)NOTE: SD NOT PERMITTED IN KITCHEN PER
 NFPA-72 8-1.4.2
  
 5)NOTE: PLEASE SEE MISSING EQUIPMENT
 GROUNDING CONDUCTOR BETWEEN MAIN DISC
 AND PANEL "B", SIZE PER 250-122
  
 6)NOTE: PLEASE LIST THE REQ`D BATH
 CIRCUIT(S) PER 210-52D/210-11-C3
  
 7)NOTE:PLEASE SHOW LOCATION OF PANEL B.
  
 8)NOTE: PLAN SHOWS TWO SD`S IN MASTER
 BEDROOM. PLEASE NOTE, TWO MAY BE
 INSTALLED, HOWEVER AN ADDITIONAL SD
 NEEDS TO BE OUTSIDE BR.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-07-31 Cont ID  
Sent By alange Date 2003-07-31 Time 09:30 Rev Time 0.00
Received By alange Date 2003-07-31 Time 09:30 Sent To B
Notes
2003-07-31 00:00:00TO LHATTEN DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-07-24 Cont ID  
Sent By alange Date 2003-07-24 Time 14:07 Rev Time 0.00
Received By alange Date 2003-07-24 Time 14:07 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-04-28 Cont ID  
Sent By shernand Date 2003-04-28 Time 13:59 Rev Time 0.00
Received By shernand Date 2003-04-28 Time 13:59 Sent To E
Notes
2003-04-28 00:00:00DP DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-03-14 Cont ID  
Sent By sthyng Date 2003-03-14 Time 13:14 Rev Time 0.00
Received By sthyng Date 2003-03-14 Time 13:14 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-04-03 Cont ID  
Sent By jleech Date 2003-03-31 Time 18:26 Rev Time 0.25
Received By hmoser Date 2003-04-03 Time 19:04 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2003-07-29 Cont ID  
Sent By kstevens Date 2003-07-29 Time 14:14 Rev Time 0.50
Received By kstevens Date 2003-07-29 Time 14:13 Sent To  
Notes
2003-07-29 00:00:00PASSED/PROVISO
  
 SHT A-3 FLOOR PLAN NEEDS REVISION TO RE-
 FLECT SANT. RISER DIAGRAM. NEW BAR SINK
 ADDED TO RISER.

Review Stop P PLUMBING
Rev No 2 Status P Date 2003-04-30 Cont ID  
Sent By alange Date 2003-07-24 Time 14:08 Rev Time 0.25
Received By kstevens Date 2003-04-30 Time 15:18 Sent To B
Notes
2003-04-30 00:00:00PASSED/PROVISO
  
 REVISION REQUIRED - EXTRA LAV ON RISER

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-03-31 Cont ID  
Sent By dpalmer Date 2003-04-29 Time 08:50 Rev Time 0.50
Received By jleech Date 2003-03-31 Time 18:26 Sent To M
Notes
2003-03-31 00:00:00DENIED;
 PAGE A-1 PLUMBING RISER DIAGRAM NOT TO
 CODE. SEC. 909.1. WET VENTS FOR BATH-
 ROOMS ARE PERMITTED TO VENT ONLY BATH-
 ROOM FIXTURES. WASHING MACHINE AND
 LAUNDRY TUB ARE REQUIRED TO DISCHARGE
 DOWN STREAM OF THE BATHROOM GROUP.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 659-8096 EXT. 8369

Review Stop Z ZONING
Rev No 1 Status P Date 2003-03-17 Cont ID  
Sent By sthyng Date 2003-03-14 Time 13:14 Rev Time 0.00
Received By sgraham Date   Time   Sent To E
Notes
***NONE***