| Plan Review Stops For Permit 03031045 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2003-11-12 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2003-11-12 |
Time |
10:42 |
Rev Time |
0.50 |
| Received By |
lsmith |
Date |
2003-11-12 |
Time |
10:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2003-04-17 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-10 |
Time |
16:16 |
Rev Time |
3.00 |
| Received By |
lhatten |
Date |
2003-04-13 |
Time |
19:26 |
Sent To |
|
|
| Notes |
| 2003-04-17 00:00:00 | REVIEW & STAMPED PLANS 04/13/2003 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2004-03-19 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-03-19 |
Time |
11:07 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-03-19 |
Time |
10:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2003-04-29 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-11 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2003-04-29 |
Time |
11:28 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-03-28 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-28 |
Time |
14:14 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-03-28 |
Time |
09:09 |
Sent To |
P |
|
| Notes |
| 2003-03-28 00:00:00 | ************ UNSAT **************** | | | | | | 1)NOTE: PLEASE SIZE GROUNDING ELECTRODE | | | CONDUCTOR PER 250-66 AND SIZED PER SEC`S | | | PER 310-15 | | | | | | 2)NOTE: PLEASE CORRELATE RISER DIAGRAM | | | AND PANELS. SHOWN AS 150AAND 200A?? | | | | | | 3)NOTE: PLEASE SEE MISSING EQUIPMENT | | | GROUNDING CONDUCTOR BETWEEN MAIN AND | | | PANEL "B". SIZE PER 250-122 | | | | | | 4)NOTE: PLEASE SEE MISSING RECEPT PER | | | 210-52C1 FOR KITCHEN COUNTERSPACE. | | | | | | 5)NOTE: PLEASE SEE MISSING REQ`D BATH | | | CIRCUIT(S) PER 210-52D/210-11-C3 | | | | | | 6)NOTE: PLEASE SEE 220-16B FOR MIN KW | | | FOR WASHER CIRCUIT. | | | | | | 7)NOTE: PLEASE SEE MASTER BEDROOM, | | | SHOWS TWO SD`S INSIDE AND NONE OUTSIDE | | | , PLEASE ADD OR MOVE SD. | | | PLEASE ALSO REMOVE SD FROM KITCHEN,\\ | | | NOT PERMITTED PER NFPA-72 8-1.4.2 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-03-11 |
Time |
11:30 |
Sent To |
|
|
| Notes |
| 2004-03-11 00:00:00 | TO DP DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2003-11-10 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-10 |
Time |
15:04 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-11-10 |
Time |
15:04 |
Sent To |
B |
|
| Notes |
| 2003-11-10 00:00:00 | TO MISC BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2003-07-16 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-07-16 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-07-16 |
Time |
10:51 |
Sent To |
B |
|
| Notes |
| 2003-07-16 00:00:00 | LHATTEN DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-07-08 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-07-08 |
Time |
16:25 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-07-08 |
Time |
16:25 |
Sent To |
B |
|
| Notes |
| 2003-07-08 00:00:00 | LHATTEN DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-05-12 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-12 |
Time |
09:37 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-12 |
Time |
09:37 |
Sent To |
|
|
| Notes |
| 2003-05-12 00:00:00 | PROCESSED PERMIT, RECEIVED IMPACT FEE & | | | NOC. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-04-28 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-28 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-04-28 |
Time |
14:14 |
Sent To |
E |
|
| Notes |
| 2003-04-28 00:00:00 | DP DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-03-14 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-03-14 |
Time |
13:15 |
Rev Time |
0.00 |
| Received By |
sthyng |
Date |
2003-03-14 |
Time |
13:15 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2003-04-03 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2003-03-31 |
Time |
17:46 |
Rev Time |
0.25 |
| Received By |
hmoser |
Date |
2003-04-03 |
Time |
18:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2003-04-30 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-04-30 |
Time |
14:53 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2003-04-30 |
Time |
14:37 |
Sent To |
B |
|
| Notes |
| 2003-04-30 00:00:00 | PASSED/PROVISO | | | | | | EXTRA LAV ON RISER DIAGRAM - REVISION | | | REQUIRED |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-03-31 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-04-29 |
Time |
11:28 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2003-03-31 |
Time |
17:46 |
Sent To |
M |
|
| Notes |
| 2003-03-31 00:00:00 | DENIED; | | | PAGE A-1 PLUMBING RISER DIAGRAM NOT TO | | | CODE. SEC. 909.1. WET VENTS FOR BATH- | | | ROOMS ARE PERMITTED TO VENT ONLY BATH- | | | ROOM FIXTURES. WASHING MACHINE AND | | | LAUNDRY TUB ARE REQUIRED TO DISCHARGE | | | DOWN STREAM OF THE BATHROOM GROUP. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 659-8096 EXT.8369 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-03-17 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-03-14 |
Time |
13:15 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
E |
|
| Notes |
|
|