| Plan Review Stops For Permit 03030999 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2003-04-28 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-04-22 |
Time |
12:47 |
Rev Time |
3.00 |
| Received By |
lsmith |
Date |
2003-04-28 |
Time |
10:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2003-12-03 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-12-03 |
Time |
12:09 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2003-12-03 |
Time |
12:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2003-12-01 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-12-01 |
Time |
12:16 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2003-12-01 |
Time |
12:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2003-04-14 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-24 |
Time |
13:27 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2003-04-14 |
Time |
17:02 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-03-26 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-10 |
Time |
12:09 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2003-03-26 |
Time |
08:59 |
Sent To |
P |
|
| Notes |
| 2003-03-26 00:00:00 | UNSAT | | | ~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | PLEASE CORRECT THE PLANS TO COMPLY WITH | | | THE FOLLOWING. | | | | | | 1} THE FEEDER FROM THE MAIN TO PANEL "A" | | | IS INCORRECT FOR 200 AMPS. | | | | | | 2} PLEASE LIST THE REQ`D ARC | | | FAULT PROTECTED CIRCUITS ON PANEL | | | SCHEDULE OR NOTE ON PLANS FOR BRANCH | | | CIRCUIT PROTECTION. PER 210-12 | | | | | | 3} PLEASE NOTE KITCHEN COUNTER- | | | -SPACE RECEPT SPACING SHALL MEET ART; | | | 210-52C 1,2,3,4,AND 5. | | | | | | 4} PLEASE NOTE THAT THE RECEPTACLE | | | SPACING IN THE DINING ROOM DOES NOT | | | COMPLY WITH 210-52(A)(1). | | | | | | 5} SMOKE DETECTORS ARE REQUIRED | | | INSIDE AND OUTSIDE ALL SLEEPING ROOMS. | | | IN THE VICINITY OF BEDROOMS AND CLOSE | | | PROXIMITY OF STAIRWAYS. 2-5.2.1.3 | | | 3'FT FROM BATHS/KITCHENS.2-5.2.1.6 | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-11-24 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-11-24 |
Time |
13:26 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-11-24 |
Time |
13:26 |
Sent To |
E |
|
| Notes |
| 2003-11-24 00:00:00 | TO BT DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-04-10 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-10 |
Time |
12:09 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-04-10 |
Time |
12:09 |
Sent To |
E |
|
| Notes |
| 2003-04-10 00:00:00 | BT DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-03-14 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-03-14 |
Time |
11:55 |
Rev Time |
0.00 |
| Received By |
sthyng |
Date |
2003-03-14 |
Time |
11:55 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2003-08-22 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-08-22 |
Time |
07:12 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2003-08-22 |
Time |
07:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2003-04-22 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-04-22 |
Time |
12:46 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2003-04-22 |
Time |
12:46 |
Sent To |
B |
|
| Notes |
| 2003-04-22 00:00:00 | MECHANICAL PERMIT 03031176 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2003-03-31 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-04-14 |
Time |
17:43 |
Rev Time |
0.25 |
| Received By |
hmoser |
Date |
2003-03-31 |
Time |
19:40 |
Sent To |
B |
|
| Notes |
| 2003-03-31 00:00:00 | PLAN DENIED | | | SEER ON ENERGY CALCS.AND PLANS DO NOT | | | MATCH | | | PLAN REVIEW BY HAROLD MOSER | | | (561)659-8096 EXT.8221 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2003-03-27 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-03-26 |
Time |
16:54 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2003-03-27 |
Time |
19:37 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-03-17 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-03-14 |
Time |
11:55 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
E |
|
| Notes |
|
|