| Plan Review Stops For Permit 03030678 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2004-12-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-12-03 |
Time |
17:09 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-12-03 |
Time |
17:08 |
Sent To |
PC |
|
| Notes |
| 2004-12-03 00:00:00 | LETTER FROM SLIDER PE RE: STRUCTURAL | | | REPAIRS | | | DATED 11/24/04 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2004-10-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-10-22 |
Time |
12:43 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2004-10-22 |
Time |
12:43 |
Sent To |
PC |
|
| Notes |
| 2004-10-22 00:00:00 | REVISION S1 PREPARED BY SLIDER ENG | | | DATED 8/12/04 | | | | | | ***PROVISO*** | | | SUBMIT TEST REPORT AND OTHER ENGINEERING | | | REPORTS AS NOTED |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2004-08-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2004-08-19 |
Time |
10:03 |
Rev Time |
1.00 |
| Received By |
shill |
Date |
2004-08-19 |
Time |
10:03 |
Sent To |
|
|
| Notes |
| 2004-08-19 00:00:00 | ****CORRECTIONS**** | | | REVISION, S1 PREPARED BY SLIDER ENG. | | | DATED 8/12/4 | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)PLEASE HAVE THE PLAN REVIEWED BY | | | THE DESIGNER OF RECORD, HARVARD JOLLY | | | CLEES TOPPE. | | | | | | 2.)THIS REVISION WILL BE ISSUED WITH | | | A PROVISO THAT TEST REPORT (SEE KEY NOTE | | | 6) AND OTHER ENGINEERING REPORTS BE | | | SUBMITTED (SUBMITTAL, NO FEE). | | | | | | ***NO RESUB FEE*** |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2003-10-22 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-16 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-10-22 |
Time |
13:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2003-03-13 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-03-13 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-03-13 |
Time |
14:34 |
Sent To |
|
|
| Notes |
| 2003-03-13 00:00:00 | PLANS DATED 2/28/03. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2003-10-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-10-10 |
Time |
08:44 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2003-10-10 |
Time |
08:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2003-05-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-05-12 |
Time |
16:18 |
Rev Time |
1.50 |
| Received By |
dpalmer |
Date |
2003-05-12 |
Time |
16:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-03-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-03-26 |
Time |
10:50 |
Rev Time |
4.00 |
| Received By |
dpalmer |
Date |
2003-03-26 |
Time |
10:15 |
Sent To |
|
|
| Notes |
| 2003-03-26 00:00:00 | ************** UNSAT *****************' | | | | | | 1)NOTE: PLEASE SEE RISER DIAGRAM. PLEASE | | | CORRELATE RISER AND PANELS SCHEDULES. | | | PLEASE SEE OHAC, SHOWN FEEDING X-FORMER | | | W/ 100A ON RISER AND 20A ON PANEL? | | | | | | 2)NOTE: PLEASE SUBMIT ALL PANEL SCHEDULE | | | -S THAT HAVE PANELS/LOADS BEING ADDED. | | | SOME PANEL SCHEDULES ARE MISSING AND | | | UNABLE TO COMPLETE REVIEW AT THIS TIME. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | EELCTRICAL PLAN REVIEW. | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2003-10-03 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-10-03 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-10-03 |
Time |
15:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2003-06-10 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-06-10 |
Time |
14:21 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-06-10 |
Time |
14:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2003-04-04 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-04-04 |
Time |
09:24 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-04-04 |
Time |
09:24 |
Sent To |
|
|
| Notes |
| 2003-04-04 00:00:00 | 1) PLEASE REVIEW MECHANICAL COMMENTS | | | WITH REGARDS TO FIRE AND OR SMOKE DAMPER | | | ISSUES. | | | | | | 2) ALL EXIT ACCESS AND EXITS SHALL | | | REMAIN CLEAR AND ACCESSIBLE AT ALL | | | TIMES. | | | | | | 3) ALL DEMOLITION, CONSTRUCTION, AND | | | RENOVATION SHALL COMPLY WITH NFPA 241. | | | | | | 4) NO NON APPROVED VISQUEEN OR NON | | | FIRE RATED MATERIALS ARE TO BE USED | | | FOR TEMPORARY WALLS. | | | | | | 5) NO EXISTING FIRE SAFETY EQUIPMENT | | | SHALL BE INTERFERED WITH BY ANY | | | RENOVATION, CONSTRUCTION, OR DEMOLITION. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2004-12-13 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-13 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-13 |
Time |
13:50 |
Sent To |
P |
|
| Notes |
| 2004-12-13 00:00:00 | SENT TO "P" BOX. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2004-12-01 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-01 |
Time |
18:25 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-01 |
Time |
18:25 |
Sent To |
B |
|
| Notes |
| 2004-12-01 00:00:00 | TO "SH" DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2004-08-16 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-16 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-16 |
Time |
16:32 |
Sent To |
B |
|
| Notes |
| 2004-08-16 00:00:00 | TO SH DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2004-06-14 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-06-14 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-06-14 |
Time |
14:46 |
Sent To |
M |
|
| Notes |
| 2004-06-14 00:00:00 | TO PK BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2004-06-07 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-07 |
Time |
14:24 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-06-07 |
Time |
14:23 |
Sent To |
P |
|
| Notes |
| 2004-06-07 00:00:00 | TO KS BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-05-25 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-05-25 |
Time |
14:35 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2004-05-25 |
Time |
14:35 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-01-20 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-16 |
Time |
16:26 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-16 |
Time |
16:26 |
Sent To |
M |
|
| Notes |
| 2004-01-16 00:00:00 | TO PK BOX/MECH ONLY/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-09-23 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-09-19 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-09-19 |
Time |
11:12 |
Sent To |
|
|
| Notes |
| 2003-09-19 00:00:00 | TO COMM BD #16/9/23/03 DEE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-05-06 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-06 |
Time |
12:56 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-06 |
Time |
12:56 |
Sent To |
|
|
| Notes |
| 2003-05-06 00:00:00 | COMM BOARD #62 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-03-11 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-03-11 |
Time |
14:32 |
Rev Time |
0.00 |
| Received By |
sthyng |
Date |
2003-03-11 |
Time |
14:32 |
Sent To |
|
|
| Notes |
| 2003-03-11 00:00:00 | COMM BOARD #32 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
P |
Date |
2004-06-22 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-06-22 |
Time |
07:47 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2004-06-22 |
Time |
07:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2004-06-03 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-06-14 |
Time |
14:46 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2004-06-03 |
Time |
08:02 |
Sent To |
|
|
| Notes |
| 2004-06-03 00:00:00 | REVISION - ROUND DUCT CONNECTIONS TO | | | FAN COIL UNITS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2004-01-29 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-05-25 |
Time |
14:35 |
Rev Time |
0.20 |
| Received By |
pkrauss |
Date |
2004-01-29 |
Time |
14:40 |
Sent To |
|
|
| Notes |
| 2004-01-29 00:00:00 | REPLACEMENT PLANS W/ENGINEER SEAL. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2004-01-28 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-01-28 |
Time |
06:34 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2004-01-28 |
Time |
06:34 |
Sent To |
|
|
| Notes |
| 2004-01-28 00:00:00 | DENIED: | | | PLANS ARE NOT SIGNED AND SEALED BY THE | | | ENGINEER.PER FS 471.025 AND THE FAC | | | 61G15-23.002 PLANS ARE TO HAVE AN | | | EMBOSSED SEAL.PLANS ARE OTHERWISE CODE | | | COMPLIANT. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2003-10-14 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-20 |
Time |
11:16 |
Rev Time |
0.50 |
| Received By |
pkrauss |
Date |
2003-10-14 |
Time |
06:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2003-06-17 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-06-17 |
Time |
13:26 |
Rev Time |
2.20 |
| Received By |
pkrauss |
Date |
2003-06-17 |
Time |
13:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2003-04-02 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-04-01 |
Time |
16:16 |
Rev Time |
7.00 |
| Received By |
pkrauss |
Date |
2003-04-01 |
Time |
14:18 |
Sent To |
|
|
| Notes |
| 2003-04-01 00:00:00 | PLEASE CLARIFY THE FOLLOWING INFORMATION | | | FOR REVIEW. | | | | | | 1.PLAN SHEET M-7 MECH RM G106, SUPPLY | | | DUCT TO MECH RM (8" ROUND) APPEARS TO | | | TERMINATE AT A SIDE WALL.DUCT MUST | | | CONTINUE WITH NO OPENINGS A MINIMUM OF | | | 5 FT FROM RATED WALL. 2001 FBC, MECH | | | 607.1.3. | | | | | | 2.PLAN SHEET M-7 24" X 12" OUTSIDE AIR | | | LOUVER, PENENTRATES A 1 HR WALL - NO | | | FIRE OR FIRE/SMOKE DAMPER INDICATED. | | | | | | 3.PLAN SHEET M-8 EXH DUCT PENETRATING | | | RM #1B165 & 1B167, RMS HAVE A 1 HR FIRE | | | RATING - NO DAMPERS INDICATED. | | | | | | 4.PLAN SHEET M-8 SUPPLY DUCT PASSING | | | THROUGH RM #1B187 & 1B185 (RATED WALL) | | | NO DAMPERS INDICATED. | | | | | | 5.PLAN SHEET M-9 DUCT PENETRATING WALL | | | BETWEEN RM # 1D316 & 1D314 (RATED WALL) | | | NO DAMPER INDICATED.EXHAUST DUCT | | | FROM RM # 1D302,(14" X 8"), NO FIRE | | | DAMPER SHOWN.EXH DUCT AT RM # 1D303 | | | INTO CORRIDOR 1D300 - NO FIRE DAMPER | | | INDICATED. | | | | | | 6.PLEASE NOTE, PLAN SHEET M-11 SHOWS | | | (E)RTU3N-2, SUPPLY DUCT TO THIRD FLOOR | | | & RETURN AIR TO SECOND FLOOR.FLOOR | | | PLAN INDICATES THIS UNIT SERVES THE | | | THIRD FLOOR AND DOES NOT GO TO THE | | | SECOND FLOOR.PLEASE CLARIFY | | | | | | 7.PLEASE CLARIFY FLOOR PENETRATIONS. | | | AS PER 2001 FBC(M) 607.4 BUILDINGS MORE | | | THAN ONE STORY IN HEIGHT, DUCTS | | | EXTENDING THROUGH MORE THAN ONE FLOOR | | | SHALL BE PROTECTED BY A SHAFT ENCLOSURE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
MEDGAS |
MEDICAL GAS |
| Rev No |
4 |
Status |
P |
Date |
2004-12-28 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-12-28 |
Time |
07:07 |
Rev Time |
0.95 |
| Received By |
kstevens |
Date |
2004-12-28 |
Time |
07:07 |
Sent To |
|
|
| Notes |
| 2004-12-28 00:00:00 | MED-GAS REVISION OK - CHANGED LOCATION | | | OF BULK STORAGE FOR OXYGEN. - 3 NEW | | | LINES TO CONNECT TO EXISTING. SHT P-16 | | | (NEW SHEET) |
|
|
| Review Stop |
MEDGAS |
MEDICAL GAS |
| Rev No |
3 |
Status |
P |
Date |
2003-10-24 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-10-22 |
Time |
14:25 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2003-10-24 |
Time |
08:58 |
Sent To |
|
|
| Notes |
| 2003-10-24 00:00:00 | REVISION OK - EXISTING MEDGAS TO REMAIN | | | SHT P-6-MINOR OFFSET AOV LINES SHT | | | P-12 |
|
|
| Review Stop |
MEDGAS |
MEDICAL GAS |
| Rev No |
2 |
Status |
P |
Date |
2003-06-17 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-06-17 |
Time |
14:06 |
Rev Time |
1.50 |
| Received By |
kstevens |
Date |
2003-06-17 |
Time |
14:06 |
Sent To |
|
|
| Notes |
| 2003-06-17 00:00:00 | PASSED PER JOHN LEECH 6-9-3 KSTEVENS |
|
|
| Review Stop |
MEDGAS |
MEDICAL GAS |
| Rev No |
1 |
Status |
P |
Date |
2003-04-07 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2003-04-07 |
Time |
20:13 |
Rev Time |
1.50 |
| Received By |
jleech |
Date |
2003-04-07 |
Time |
20:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2003-10-21 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-06-07 |
Time |
14:24 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2003-10-21 |
Time |
18:10 |
Sent To |
|
|
| Notes |
| 2003-10-21 00:00:00 | REVISION OK - CHANGES IN FLOOR PLAN - | | | WATER PIPING - SANITARY PIPING |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2003-06-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-06-06 |
Time |
11:44 |
Rev Time |
1.50 |
| Received By |
kstevens |
Date |
2003-06-06 |
Time |
11:44 |
Sent To |
|
|
| Notes |
| 2003-06-06 00:00:00 | PASSED/PROVISO | | | | | | WATER HAMMER ARRESTORS SHALL BE LOCATED | | | NEAR THE FIXTURE IN AN "EFFECTIVE RANGE" | | | NOT AT THE TOP OF THE DROP IN THE CEIL- | | | ING. PDI-WH 201 AND MANUF. INSTALLATION | | | INSTRUCTIONS. | | | | | | | | | | | | PROVISO | | | SEE SHEET 13, ICE MACHINE DETAIL FOR | | | CORRECT INSTALLATION. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-03-28 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-03-28 |
Time |
09:19 |
Rev Time |
3.75 |
| Received By |
kstevens |
Date |
2003-03-27 |
Time |
18:46 |
Sent To |
|
|
| Notes |
| 2003-03-28 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | 1) SHT P-3 BATHROOM BY STAFF NEXT TO | | | STAIR #1, INDICATES TUB TO STAY (1), BUT | | | SHOWS ALL PIPING REMOVED. PLEASE CLAIRFY | | | 2) SHT P.3 ROOMS 1503 & 1504, DOES 2" | | | WASTE REMAIN? NOT DESIGNATED WITH (8). | | | 3) SHTS P-9 & P-11 PLUMBING DRAWING | | | NOTES #'S 3 & 6 FLOOR SINK REQUIRED FOR | | | INDIRECT WASTE. SEC 802.3 (SEE DETAIL ON | | | SHT P-13) | | | - PLUMBING DRAWING NOTES #'S 4 & 5, | | | CONDENSATE SHALL NOT DRAIN INTO SANT. | | | PER CITY CODE 31-62(5). CONDENSATE SHALL | | | BE PIPED SEPARATELY OUT OF THE BLDG. AND | | | TIE INTO STORM SEWER, CATCH BASIN OR DRY | | | WELL. A RELIEF VENT IS REQUIRED AS COND. | | | EXITS BLDG. | | | 4) SHT P-13 ICE MACHINE CONNECTION DE- | | | TAIL, DRAIN FROM CUBER & ICE BIN TO RUN | | | TO THE FLOOR SINK SEPARATELY. | | | 5) SHT P.14 ALL WATER RISER DIAGRAMS, | | | WATER HAMMER ARRESTORS SHALL BE LOCATED | | | NEAR THE FIXTURE IN AN "EFFECTIVE RANGE" | | | NOT IN THE CEILING AT THE TOP OF THE | | | DROP AS SHOWN. PDI-WH 201 & MANUFACTURE | | | INSTALLATION INSTRUCTIONS. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|