Plan Review Details - Permit 03030634
Plan Review Stops For Permit 03030634
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2003-04-03 Cont ID  
Sent By pkrauss Date 2003-03-14 Time 13:54 Rev Time 2.00
Received By sthyng Date 2003-04-02 Time 20:05 Sent To  
Notes
2003-04-02 00:00:00**********PROVISO************
  
 1.)HURRICANE PROTECTION REQUIRED FOR
 WINDOW.PLEASE PROVIDE PRODUCT APPROVALS;
 TWO LEGIBLE COPIES.
  
 2.)PLEASE PROVIDE TWO COPIES OF
 PRODUCT APPROVALS FOR THE WINDOW AND
 EXTERIOR DOOR.
  
 3.) STUCCO TO BE 7/8" THICKNESS.
  
 4.)2001 FL BLD CODE, 1005.4:
 PROVIDE EMERGENCY EGRESS WINDOWS IN
 SLEEPING ROOMS WITH A MINIMUM NET CLEAR
 OPENING HEIGTH OF 24" AND NET CLEAR
 OPENING WIDTH OF 20" AND A NET CLEAR
 OPENING AREA OF 5.7 SQ.FT. GROUND FLOOR
 OPENINGS ARE PERMITTED TO HAVE A NET
 CLEAR OPENING OF 5.0 SQ. FT. SILL HEIGTH
 SHALL NOT BE MORE THAN 44 " ABOVE THE
 FINISH FLOOR.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-03-14 Cont ID  
Sent By sthyng Date 2003-03-13 Time 16:04 Rev Time 0.50
Received By btrobaug Date 2003-03-14 Time 13:05 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-03-13 Cont ID  
Sent By sthyng Date 2003-03-13 Time 16:04 Rev Time 0.00
Received By sthyng Date 2003-03-13 Time 16:04 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-03-07 Cont ID  
Sent By sgraham Date 2003-03-12 Time 10:23 Rev Time 0.00
Received By dpalmer Date 2003-03-07 Time 11:38 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-03-14 Cont ID  
Sent By kstevens Date 2003-03-14 Time 13:44 Rev Time 0.30
Received By pkrauss Date 2003-03-14 Time 13:48 Sent To B
Notes
2003-03-14 00:00:00PROVISO:
  
 MECHANICAL VENTILATION REQUIRED FROM
 BATHROOM, AS PER 2001 FBC(M) 402.3.1 IN
 ACCORDANCE WITH TABLE 403.3.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-03-14 Cont ID  
Sent By btrobaug Date 2003-03-14 Time 13:35 Rev Time 0.25
Received By kstevens Date 2003-03-14 Time 13:44 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-03-12 Cont ID  
Sent By dpalmer Date 2003-03-07 Time 11:38 Rev Time 0.00
Received By sgraham Date   Time   Sent To I
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved