Plan Review Details - Permit 03030362
Plan Review Stops For Permit 03030362
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2004-02-27 Cont ID  
Sent By jwitmer Date 2004-02-27 Time 15:42 Rev Time 1.00
Received By jwitmer Date 2004-02-27 Time 15:42 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2004-02-26 Cont ID  
Sent By csiegber Date 2004-02-27 Time 12:14 Rev Time 1.20
Received By jwitmer Date 2004-02-26 Time 13:51 Sent To  
Notes
2004-02-26 00:00:00BUILDING PLAN REVIEW
 PERMIT: 03030362
 ADD: 921 ALAMANDA AVE
 CONT: O/B VILA, RAFAEL
 TEL: (561)502-6851
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 NOTE: PLANS ARE CODE COMPLIANT!!!!!!
  
 PERMIT CAN NOT BE ISSUED UNTIL:
 1) OWNERS SIGN BACK OF THE PERMIT APP-
 LICATION AND NOTIRIZED.
 2) FILE NOTICE OF COMMENCEMENT
 3) PLANS TO COUNTY FOR IMPACT FEES
 4) RESUBMIT PLANS TO CITY FOR FINAL
 STAMPING AND ISSUANCE!!!!!
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2004-01-13 Cont ID  
Sent By pkrauss Date 2004-02-12 Time 12:24 Rev Time 1.25
Received By jwitmer Date 2004-01-13 Time 09:58 Sent To  
Notes
2004-01-13 00:00:00BUILDING PLAN REVIEW
 PERMIT: 03030362
 ADD: 921 ALAMANDA AVE
 CONT: O/B VILA, RAFAEL
 TEL: (561)585-9054
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 2ND REVIEW
 ACTION: DENIED
  
 1) DUPICATE PERMIT APPLICATION NOT
 SIGNED AND NOTIRIZED.
  
 2) AS STATED FROM THE FIRST REVIEW COM-
 MENT# 1, OWNER/ BUILDERS ARE TAKING AND
 EXEMPTION TO PULL THEIR OWN PERMIT UNDER
 FL S.S. 489.1. THE OWNER/ BUILDER MAY
 PULL PERMITS FOR THE RESIDENCE THEY LIVE
 IN! THEY CAN NOT PULL PERMITS FOR ANOTH-
 ER PROPERTY FOR ONE (1) YEAR AFTER THE
 C.O. PERMITS WERE PULLED ON 639 GLEN-
 RIDGE, C/O ON 01/31/03. THIS PERMIT AS A
 OWNER/ BUILDER MAY NOT BE ISSUED UNTIL
 (1) YEAR AFTER THIS C.O. DATE.
 THE OWNER/ BUILDER DISCLOSURE STAT-
 MENT THAT YOU SIGNED INDICATES THAT THIS
 PROPERTY WILL BE YOUR RESIDENCE SINCE IT
 CAN NOT BE USED FOR LEASE OR FOR SALE
 UNTIL (1) YEAR AFTER THE C.O.
  
 3)BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH
 THE PLANS WHEN RESUBMITTING PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN
 BE FOUND, WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
 JIM WITMER
 BUILDING PLAN REVIEW
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-04-29 Cont ID  
Sent By pkrauss Date 2003-04-23 Time 13:13 Rev Time 4.00
Received By jwitmer Date 2003-04-29 Time 15:48 Sent To  
Notes
2003-04-29 00:00:00 
 BUILDING PLAN REVIEW
 PERMIT: 03030362
 ADD: 921 ALLAMANDA AVENUE
 CONT: O/B VILA, RAFAEL
 TEL: (561)585-9054
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1) CONTRACTOR WILL BE REQUIRED TO BUILD
 THIS STRUCTURE, FLORIDA STATE STATUTE
 489.1 OWNER/ BUILDER DISCLOSURE STATE-
 MENTS FROM 639 GLENRIDGE ARE LESS THAN
 1 YEAR FROM C.O. ADDING 2 CAR GARAGE
 FINALED 10/08/02.
 REPAIR METAL LATH & STUCCO 01/31/03.
  
 2) FL BLD CODE 1804.2.2 QUESTIONABLE
 SOILS, WHERE THE BEARING CAPACITY IS
 NOT DEFINETLY KNOWN OR IS IN QUESTION.
 PROVIDE SEALED SOILS REPORT, SOILS
 INVESTIGATION PROVIDING MINIMUM SAFE
 SOIL BEARING VALUE.
  
 3)PROVIDE ENERGY CALCULATIONS AND
 EQUIPMENT SIZING CALCULATIONS (MANUAL J)
 AS REQUIRED BY THE 2001 FLORIDA ENERGY
 EFFICIENTCY CODE FOR BUILDING CONSTRUC-
 TION.
  
 4)1503.4.4 PROTECTION AGAINST DECAY &
 TERMITES. CONDENSATE LINES & ROOF DOWN
 SPOUTS SHALL DISCHARGE AT LEAST 1 FT.
 AWAY FROM THE STRUCTURE SIDEWALL,
 WHETHER BY UNDERGROUND PIPING, TAIL EX-
 TENSIONS, OR SPLASH BLOCKS.
  
 5)1606.1.4(1) IN WIND BORNE DEBRIS
 REGIONS, EXTERIOR GLAZING THAT RECEIVES
 POSITIVE PRESSURE IN BUILDINGS SHALL BE
 ASSUMED TO BE OPENINGS UNLESS SUCH
 GLAZING IS IMPACT RESISTANT OR PROTECTED
 WITH AN IMPACT RESISTANT COVERING MEET-
 ING THE REQUIREMENTS OF SSTD 12, ASTM
 E 1886 AND ASTM E 1996 OR MIAMI-DADE.
 1) GLAZED OPENINGS LOCATED WITHIN 30 FT
 OF GRADE SHALL MEET THE REQUIREMENTS OF
 LARGE MISSLE TEST.
  
 6) FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORT, SBCCI OR DADE COUNTY
 REPORT ARE ACCEPTED. MISSING REPORTS
 A) SINGLE HUNG WINDOW MISSING THE
 TECHNICAL DRAWINGS97-002
 B) MULLIONS
 C) SOLID EXTERIOR DOOR, SINGLE/ PAIR
 D) ROOFINGASSEMBLIES
 E) STORM SHUTTERS
  
 7) HURRICANE TESTING LAB: REQUIRES
 SITE SPECIFIC ENGINEERING (PRODUCT
 APPROVAL) REQUIRES THE WET SIGNATURE,
 DATE AND EMBOSSED SEAL OF THE ENGINEER
 CERTIFYING THE PRODUCT AND SIGNATURE
 AND SEAL OF THE DESIGN PROFESSIONAL
 OF RECORD. SEE ATACHMENT.
  
 8) PROVIDE STORM PANEL INFORMATION WITH
 INSTALLATION SCHEDULE AND KEY PLAN WITH
 SPECIFIC ANCHORS AND MOUNTING TO BE USED
 FOR ALL NON-IMPACT GLAZING.
 FBC 1606.1.4.
  
 9)FL BLD CODE 2001 SECTION 103.6,
 1606.1.4, 1707.4 & 3401.7.2.4.
 PROCEDURES: 1(B) A COMPLETE INSTALLATION
 SCHEDULE SUMMARIZING & IDENTIFYING
 OPENING SIZES, STORY HEIGHTS, UNIT MARK
 NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM
 BAR REINFORCING REQUIREMENTS, WALL PRES-
 SURE ZONES, SLAT TYPES, ETC., SHALL BE
 SUBMITTED AT TIME OF PERMIT APPLICATION
 TO FACILITATE PLAN REVIEW AND PERMIT
 ISSUANCE.
  
 10) 1707.4.5.1 MULLIONS OCCURRING
 BETWEEN INDIVIDUAL WINDOW AND GLASS
 DOOR ASSEMBLIES. TESTING REPORTS ARE
 REQUIRED BY AN APPROVED TESTING
 LABORATORY OR BE ENGINEERED.
  
 11)FL BLD CODE 2001 SECTION 103.6,
 1606.1.4, 1707.4 & 3401.7.2.4.
 PROCEDURES: 1(B) A COMPLETE INSTALLATION
 SCHEDULE SUMMARIZING & IDENTIFYING
 OPENING SIZES, STORY HEIGHTS, UNIT MARK
 NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM
 BAR REINFORCING REQUIREMENTS, WALL PRES-
 SURE ZONES, SLAT TYPES, ETC., SHALL BE
 SUBMITTED AT TIME OF PERMIT APPLICATION
 TO FACILITATE PLAN REVIEW AND PERMIT
 ISSUANCE. SEE ATTACHMENT.
  
 12)1707.4.4.2. TAPERED WINDOW BUCKS
 SHALL EXTEND BEYOND THE INTERIOR FACE
 OF THE WINDOW OR DOOR FRAME SUCH THAT
 FULL SUPPORT OF THE FRAME IS PROVIDED.
  
 13) 1707.4.4.1 ANCHOR REQUIREMENTS:
 WINDOW & DOOR ASSEMBLIES SHALL BE ANCHOR
 ED IN ACCORDANCE WITH THE PUBLISHED
 MANUFACTURER'S RECOMMENDATIONS TO
 ACHIEVE THEDESIGN PRESSURE SPECIFIED.
 SUBSTITUTE ANCHORING SYSTEM USED FOR
 THE SUBSTRATE NOT SPECIFIED BY THE
 FENESTRATION MANUFACTURER SHALL PROVIDE
 EQUAL OR GREATER ANCHORING AS DEMONSTRA-
 TED BY ACCEPTED ENGINEERING PRACTICES.
  
 14)1707.4.3 EACH EXTERIOR DOOR
 ASSEMBLY NOT COVERED BY 1707.4.2
 (GLAZED DOORS) SHALL BE LISTED AND TEST-
 ED FOR A PERIOD EQUAL TO THE QUANITY
 3600/ V WHERE THE TIME PERIOD IS IN
 SECTIONS AND V IS IN MILES PER HR TAKEN
 FROM FIGURE 1606. THE TIME PERIOD SHALL
 ALSO INCLUDE A 10 SECOND PERIOD AT A
 LOAD EQUAL TO 1.5 TIMES THE DESIGN
 PRESSURE. DADE COUNTY & SBCCI REPORTS
 ARE ACCEPTED.
  
 15)2504.2.2 INSTALLATION OF EXTERIOR
 LATHING AND FRAMING SHALL COMPLY WITH
 ASTM C-1063.
 SHET 3/5 NOTE # 2 ON CEILING RIB LATH,
 ASTM C-1063.7.10.1.1. METAL PLASTER BASE
 SHALL BE ATTACHED TO SUPPORTS AT NO MORE
 THAN 7 " ALONG SUPPORTS "EXCEPT FOR
 3/8" RIB LATH THAT SHALL BE ATTACHED AT
 EACH RIB (4").
  
 16)1903.5.3 REINFORCEMENT SHALL CON-
 FORM TO ACI 318.CONCERNS OVER TIE
 BEAM SCHEDULE MARK # 4, 16'X 1'-8",
 WITH 2/#5 TOP, 2/#5 BOTTOM + TRUSS BAR.
 PLANS DO NOT INDICATE THE USE OF
 STIRRUPS NOR DOES THE PLAN GIVE ANY
 DETAILS FOR THE TRUSS BAR, WILL DETAILS
 BE COMING INDICATINGHOW THE ENDOF THE
 BARS WILL OCCUR SINCE THIS SHOULD BE
 CONSIDERED A END SPAN? NOT A SINGLE NOR
 INTERIOR SPAN.( END RESTRAINTS).
  
 17)BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH
 THE PLANS WHEN RESUBMITTING PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN
 BE FOUND, WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
 JIM WITMER
 BUILDING PLAN REVIEW
 TEL: (561)659-8096 X 8412
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2004-02-10 Cont ID  
Sent By dpalmer Date 2004-02-10 Time 12:17 Rev Time 1.00
Received By dpalmer Date 2004-02-10 Time 11:09 Sent To P
Notes
2004-02-10 00:00:00PLANS REDLINED FOR OCP SHOWN FOR AHU
 10KW HEAT MIN 125% PER 424.3B
 GROUNDING ELECTRODE PER 250.50.

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2003-12-29 Cont ID  
Sent By csiegber Date 2004-02-04 Time 10:14 Rev Time 0.75
Received By dpalmer Date 2003-12-29 Time 14:47 Sent To P
Notes
2003-12-29 00:00:00************** UNSAT *****************
  
 ***OWNER BUILDER PERMIT MAT NOT BE
 PULLED DUE TO PRIOR PERMITS ISSUED TO
 SAME OWNER PER FS 489
 THIS WAS COMMENTED ON PREVIOUS REVIEW
 AND IS STILL COMING BACK WITH OUT A
 CONTRACTOR.
  
 1)NOTE: PLEASE SEE THAT ONE SET OF PLANS
 IS NOW BEING KEPT ON FILE FOR RECORD
 FOR VIOLATIONS UNDER FS 471 AND FAC
 61G15-23.002
 PLANS ARE STILL MISSING INFORMATION AS
 REQUIRED UNDER THE ABOVE FS /FAC.
 PLANS WILL BE KEPT TO BE TURNED INTO
 THE FBPE'S FOR SAID VIOLATIONS.
  
 2)NOTE: PLANS STILL DO NOT SHOW BATHS
 AS 20A AS PER 210.11C3.
 PREVIOUS COMMENT.
  
 3)NOTE: PLEASE SEE THAT LOAD CALCULATION
 -S HAVE NOT BEEN REVISED DUE TO COMMENT
 FOR AHU HEAT. PLANS NOW SHOW 10 KW.
 PLEASE ADJUST.
  
 4)NOTE: PLEASE SEE 424.3B FOR OCP OF
 AHU/ HEAT. SHOWN AS 30A'S.
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW EITHER WHEN SUBMITTED BY A CONTR-
 -ACTOR OR AFTER TIME IN FS HAS BEEN
 REACHED.
 IF THERE ARE ANY QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2003-04-23 Cont ID  
Sent By csiegber Date 2003-12-19 Time 16:37 Rev Time 0.50
Received By dpalmer Date 2003-04-23 Time 07:11 Sent To P
Notes
2003-04-23 00:00:00**PLANS WERE OUTFRONT DENIED BY ZONING**
 ******* TO ELECTRICAL 4/23/03***********
 PLEASE NOTE, OWNER/BLDR PERMIT CAN NOT
 BE PULLED. FS 489
 *************** UNSAT*******************
  
  
 1)NOTE: PLEASE SEE MISSING RECEPT FOR
 KITCHEN COUNTERSPACE PER 210-52C-1
 PLEASE ALSO SEE MISSING RECEPT FOR
 KITCHEN PENINSULAR 210-52C2/3, ALSO GFI.
 210-8A-6
  
 2)NOTE: PLEASE SEE MISSING HALLWAY
 RECEPTS PER 210-52H
  
 3)NOTE: PLEASE LIST THE REQ`D BATH(S)
 CIRCUIT(S) AS 20A /#12 AWG. 210-52D/
 210-11C-3
  
 4)NOTE: PLEASE SEE GROUNDING ELECTRODE,
 NEEDS TO BE SHOWN TO FOOTER STEEL ALSO
 PER 250-50.
  
 5)NOTE: PLEASE SHOW SIZE OF SEC'S, ARE
 THEY THE SAME AS CONDUCTORS FROM METER
 TO MAIN?
  
 6)NOTE: PLEASE CORRELATE SIZE OF HEAT-
 -STRIP. ELECTRICAL PLAN SHOWS 5KW(SMALL
 FOR A HOUSE THIS SIZE) A/C PLAN SHOWS
 10KW?
  
 7)NOTE: PLEASE SEE MISSING RECEPT PER
 210-52 MASTER BR.
  
 PLEASE ADJUST LOAD CALCS UPON REVISED
 A/C HEAT.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS ,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-02-27 Cont ID  
Sent By csiegber Date 2004-02-27 Time 12:14 Rev Time 0.00
Received By csiegber Date 2004-02-27 Time 12:14 Sent To B
Notes
2004-02-27 00:00:00TO JW DESK/SUBMITTALS

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-02-04 Cont ID  
Sent By csiegber Date 2004-02-04 Time 10:14 Rev Time 0.00
Received By csiegber Date 2004-02-04 Time 10:14 Sent To E
Notes
2004-02-04 00:00:00TO DP DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-12-19 Cont ID  
Sent By csiegber Date 2003-12-19 Time 16:37 Rev Time 0.00
Received By csiegber Date 2003-12-19 Time 16:37 Sent To E
Notes
2003-12-19 00:00:00TO DP DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-03-06 Cont ID  
Sent By dpalmer Date 2003-03-06 Time 10:52 Rev Time 0.00
Received By dpalmer Date 2003-03-06 Time 10:52 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2004-02-12 Cont ID  
Sent By pkrauss Date 2004-02-12 Time 12:24 Rev Time 0.30
Received By pkrauss Date 2004-02-12 Time 12:05 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2004-01-09 Cont ID  
Sent By jleech Date 2004-02-11 Time 14:27 Rev Time 0.35
Received By pkrauss Date 2004-01-09 Time 10:46 Sent To  
Notes
2004-01-09 00:00:00DENIED:
 PLAN SHEET 5 OF 5 UNDER NOTES: RETURN
 AIR FROM ROOMS WITH CLOSED DOORS SHALL
 BE EQUAL TO THE SUPPLY AIR TO THAT
 SPACE.PLEASE NOTE RETURN AIR
 REQUIREMENTS WERE REVISED JUNE 30,2003
 SEE ATTACHED SCHEDULE FOR RETURN AIR
 REQUIREMENTS.
  
 SEE COMMENTS BY D. PALMER, ELECTRICAL
 PLAN REVIEW.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2003-04-23 Cont ID  
Sent By kstevens Date 2004-01-05 Time 13:15 Rev Time 0.40
Received By pkrauss Date 2003-04-23 Time 13:00 Sent To B
Notes
2003-04-23 00:00:00DENIED:MECHANICAL PERMIT 03030393
  
 1.PROVIDE ENERGY & MANUAL J CALCS AS
 PER 2001 FBC CHAPTER 13.
  
 2.PROVIDE OUTSIDE AIR CALCS AS PER
 2001 FBC(M) TABLE 403.3.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 3 Status P Date 2004-02-11 Cont ID  
Sent By jleech Date 2004-02-11 Time 14:26 Rev Time 0.33
Received By jleech Date 2004-02-11 Time 14:26 Sent To M
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2004-01-05 Cont ID  
Sent By dpalmer Date 2004-02-10 Time 12:17 Rev Time 0.33
Received By kstevens Date 2004-01-05 Time 13:15 Sent To M
Notes
2004-01-05 00:00:00DENIED
 REFERENCE: FLA. ADMIN. CODE
 FLA. STATUTES
  
 1) OWNER BUILDER PERMIT MAY NOT BE
 ISSUED DUE TO PRIOR PERMITS ISSUED TO
 SAME OWNER. FS 489
 2) ENGINEERS SHALL LEGIBLY INDICATE
 THEIR NAME, ADDRESS, AND LICENSE NUMBER
 ON EACH SHEET. NOT ALL SHEETS HAVE THE
 LICENSE NUMBER IN THE TITLE BLOCK.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-04-23 Cont ID  
Sent By dpalmer Date 2003-12-29 Time 15:52 Rev Time 0.50
Received By kstevens Date 2003-04-23 Time 10:51 Sent To  
Notes
2003-04-23 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1) SANITARY RISER DIAGRAM DOES NOT RE-
 FLECT THE FLOOR PLAN. NO TUB SHOWN IN
 2ND BATHROOM. PLEASE SEE ATTACHED SHEET
 FOR REFERENCE AS TO REFLECTING FLOOR
 PLAN.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377
 (561) 805-6721
 FAX (561) 653-2692

Review Stop Z ZONING
Rev No 1 Status P Date 2003-03-24 Cont ID  
Sent By dpalmer Date 2003-03-06 Time 10:56 Rev Time 0.00
Received By sgraham Date   Time   Sent To E
Notes
***NONE***