| Plan Review Stops For Permit 03030352 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2003-04-26 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-08 |
Time |
13:05 |
Rev Time |
1.00 |
| Received By |
sthyng |
Date |
2003-04-26 |
Time |
15:37 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-04-14 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-04-26 |
Time |
13:24 |
Rev Time |
5.00 |
| Received By |
sthyng |
Date |
2003-04-07 |
Time |
20:16 |
Sent To |
|
|
| Notes |
| 2003-04-07 00:00:00 | **********CORRECTIONS************ | | | | | | 1.)BEFORE A PERMIT TO CONSTRUCT MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY.THE ACTUAL SET OF | | | PLANS MUST BE STAMPED BY THAT OFFICE, | | | AND A COPY OF THE PAID RECEIPT ATTACHED | | | TO THE PERMIT APPLICATION.PLEASE CALL | | | 561-233-5025 FOR MORE INFORMATION.THIS | | | CAN BE DONE AFTER THE PLANS HAVE BEEN | | | APPROVED BUT BEFORE THE PERMIT CAN BE | | | ISSUED. | | | | | | 2.)PLANS MUST COMPLY WITH FBC 3407.1.2 | | | IN REGARDS TO ADDITIONS OF GREATER THAN | | | 25%. | | | | | | 3.)ENERGY CALCS AND MANUAL J REQUIRED | | | FOR ADDITIONS PER FBC 13-101.2.2. | | | | | | 4.)CITY AMENDMENTS TO THE FBC, REVISED | | | TABLE 2306.1, FASTENING SCHEDULE FOR | | | ROOF SHEATHING IS ATTACHED.PLEASE | | | REVISE. | | | | | | 5.)FIREBLOCKING IS REQUIRED PER FBC | | | 705.3.1.1. | | | | | | 6.)PLEASE CLARIFY AS TO WHETHER THIS | | | IS A HAND FRAMED ROOF OR IF YOU WILL BE | | | USING ENGINEERED TRUSSES. | | | | | | 7.)PROVIDE A GABLE END BRACING DETAIL. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | | 561-805-6724 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2004-01-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-01-05 |
Time |
14:40 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-01-05 |
Time |
14:38 |
Sent To |
|
|
| Notes |
| 2004-01-05 00:00:00 | REDLINED # OF CONDUCTORS | | | REDLINED EQUIPMENT GRND. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2003-05-06 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-23 |
Time |
15:28 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-05-06 |
Time |
17:54 |
Sent To |
B |
|
| Notes |
| 2003-05-06 00:00:00 | REDLINED EQUIPMENT GROUNDING CONDUCTOR | | | FROM MAIN DISC TO PANEL. 250-122 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2003-04-30 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-05 |
Time |
14:29 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2003-04-30 |
Time |
15:25 |
Sent To |
|
|
| Notes |
| 2003-04-30 00:00:00 | ************ UNSAT ****************** | | | | | | PLEASE NOTE, NOW PLANS ARE BEING | | | SUBMITTED SHOWING NEW RISER AS MENTIONED | | | ON PREVIOUS PLANS. THE FOLLOWING ARE | | | COMMENTS FOR NEW ELECTRICAL PLAN | | | SUBMITTED. | | | | | | 1)NOTE: PLEASE CORRELATE RISER DIAGRAM, | | | PANELS, AND LOAD CALCUALTIONS. SOME | | | SHOWN AS 100A AND OTHER AT 150A. | | | PLEASE SHOW SERVICE/ PANEL(S) LOCATION | | | ON PLANS.PLEASE NOTE, NOT MORE THAN 8' | | | OF UNPROTECTED CONDUCTOR ARE PERMITTED | | | INSIDE HOUSE .230-70/LOCAL AMENDMENTS | | | | | | 2)NOTE: PLEASE REMOVE EQUIPMENT GROUND- | | | -ING CONDUCTOR BETWEEN METER AND MAIN | | | 250-24 | | | | | | 3)NOTE: PLEASE CLARIFY AND SHOW NEW | | | AND EXISTING LOAD CALCULATIONS COMBINE | | | AS REQ`D IN ART 220/ 215-5. NEC | | | | | | 4)NOTE: PLEASE CLARIFY NEW AND EXSITING | | | HEAT FOR AHU`S. SHOWS 10KW AND 7.5KW. | | | | | | 5)NOTE: PLEASE SEE MISSING RECEPT PER | | | 210-52 IN MASTER BEDROOM. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | | | | PLEASE SEE ATTACHED LETTER FOR PLANS | | | PER FS 553.80(2)(B) |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2003-04-25 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-28 |
Time |
11:34 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2003-04-25 |
Time |
09:50 |
Sent To |
|
|
| Notes |
| 2003-04-25 00:00:00 | *************** UNSAT ************* | | | | | | 1)NOTE: PLEASE SEE THAT NO NEW E-SHEETS | | | WERE SUBMITTED IN NEW SETS TO ADDRESS | | | FIRST REVIEW COMMENTS. | | | | | | PLEASE ADDRESS ORIG COMMENT AND INSERT | | | NEW SHEETS FOR REVIEW. IF THERE ARE ANY | | | QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-04-02 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-18 |
Time |
16:05 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2003-04-02 |
Time |
18:09 |
Sent To |
P |
|
| Notes |
| 2003-04-02 00:00:00 | ************ UNSAT **************** | | | | | | 1)NOTE: PLEASE SUBMIT ONE SET OF LOAD | | | CALCULATIONS FOR NEW AND EXISTING. | | | | | | 2)NOTE: PLEASE SEE NOTES, #11 MENTIONS | | | NEW 150A SERVICE AND NO RISER DIAGRAM | | | WAS SUBMITTED? PLEASE SUBMIT, SEC`S | | | CONDUITS, AIC RATING FOR NEW MAIN/PANELS | | | ETC. ETC. 215-5/110-9 | | | | | | 3)NOTE: PLEASE CLARIFY NEW OR EXSITING | | | WATER HEATER AND LOAD? NOT SHOWN ON | | | EXISTING OR NEW LOAD CALCS? | | | | | | 4)NOTE: PLEASE RECONFIURE LOAD CALCS | | | TO MEET NEC 220. | | | | | | 5)NOTE: PLEASE SEE MISSING RECEPT PER | | | 210-52 ON WALL OUTSIDE BEDROOM. SITTING | | | ROOM? | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2003-12-23 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-23 |
Time |
15:28 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-23 |
Time |
15:28 |
Sent To |
E |
|
| Notes |
| 2003-12-23 00:00:00 | TO DP DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2003-12-16 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-16 |
Time |
12:26 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-16 |
Time |
12:26 |
Sent To |
E |
|
| Notes |
| 2003-12-16 00:00:00 | TO DP DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2003-05-08 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-08 |
Time |
13:05 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-08 |
Time |
13:05 |
Sent To |
B |
|
| Notes |
| 2003-05-08 00:00:00 | STHYNG. RETURNED W/ PAID IMPACT FEES. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2003-05-05 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-05 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-05 |
Time |
14:29 |
Sent To |
E |
|
| Notes |
| 2003-05-05 00:00:00 | DP DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-04-28 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-28 |
Time |
11:34 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-04-28 |
Time |
11:34 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-04-18 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-18 |
Time |
16:04 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-04-18 |
Time |
16:04 |
Sent To |
E |
|
| Notes |
| 2003-04-18 00:00:00 | DP DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-03-24 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-03-24 |
Time |
12:58 |
Rev Time |
0.00 |
| Received By |
sthyng |
Date |
2003-03-24 |
Time |
12:58 |
Sent To |
E |
|
| Notes |
| 2003-03-24 00:00:00 | TO ELEC IN BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-03-06 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2003-03-24 |
Time |
12:44 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2003-03-06 |
Time |
12:56 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2003-04-28 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2003-04-28 |
Time |
07:49 |
Rev Time |
0.25 |
| Received By |
hmoser |
Date |
2003-04-28 |
Time |
07:48 |
Sent To |
|
|
| Notes |
| 2003-04-28 00:00:00 | SUBMIT PLANS,MANUAL(J) WITH APPLICATION |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2003-04-26 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-04-26 |
Time |
15:48 |
Rev Time |
0.25 |
| Received By |
hmoser |
Date |
2003-04-26 |
Time |
12:49 |
Sent To |
P |
|
| Notes |
| 2003-04-26 00:00:00 | PLAN DENIED | | | NO A/C PLANS,OR ENERGY CALCULATIONS | | | PLAN REVIEW BY HAROLD MOSER | | | (561)805-6732 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2003-04-07 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-04-03 |
Time |
17:15 |
Rev Time |
0.50 |
| Received By |
hmoser |
Date |
2003-04-07 |
Time |
17:27 |
Sent To |
B |
|
| Notes |
| 2003-04-07 00:00:00 | MECHANICAL CONTRACTOR NEEDS PLANS,MANUAL | | | (J) ENERGY CALCULATIONS FOR PERMIT | | | PLAN REVIEW BY HAROLD MOSER | | | (561)659-8096 EXT.8221 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2003-04-26 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-04-26 |
Time |
13:24 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2003-04-26 |
Time |
13:23 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2003-04-03 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2003-04-26 |
Time |
12:50 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2003-04-03 |
Time |
17:14 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-03-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-03-06 |
Time |
12:56 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
I |
|
| Notes |
|
|