Plan Review Details - Permit 03030105
Plan Review Stops For Permit 03030105
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-04-14 Cont ID  
Sent By sthyng Date 2003-04-14 Time 17:40 Rev Time 2.50
Received By sthyng Date 2003-04-14 Time 17:40 Sent To  
Notes
2003-04-14 00:00:00SEVERAL COMMENTS ADDRESSED BY CONTRACTOR
 PROVIDING ORIGINAL PLANS FOR THE PORCH,
 PERMIT #02071390.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-04-02 Cont ID  
Sent By btrobaug Date 2003-04-14 Time 14:24 Rev Time 2.50
Received By sthyng Date 2003-04-01 Time 12:15 Sent To  
Notes
2003-04-01 00:00:00**********CORRECTIONS************
  
 1.)BEFORE A PERMIT TO CONSTRUCT MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 2.)ENERGY CALCS REQUIRED FOR NEW A/C
 AREA.
  
 3.)PROVIDE PRODUCT APPROVALS FOR THE
 FOLLOWING ITEMS:
 A.FRENCH DOORS
 B.HORIZONTAL SLIDERS
 C.WINDOW BEING RELOCATED FROM
 EXISTING RESIDENCE
 D.HURRICANE SHUTTERS IF WINDOWS/
 DOORS ARE NOT IMPACT
  
 4.)FBC 1606.1.7, INTERNAL PRESSURE
 COEFFICIENT IS REFERRED TO BUT THE
 COEFFICIENT IS NOT ON THE TABLE.THIS
 NUMBER SHOULD BE .18 FOR AN ENCLOSED
 BUILDING.PLEASE REVISE.
  
 5.)PLEASE GIVE ADDITIONAL INFORMATION
 IN REGARDS TO THE EXISTING 6 4X4 POSTS;
 UPLIFT, ATTACHMENTS, MATERIALS,
 LOAD BEARING CAPACITY.
  
 6.)THE WALL SECTION SHOULD SPECIFY
 ATTACHMENTS FOR THE PLYWOOD SHEATHING
 AND THE RBB SIDING.
  
 7.)INSULATION REQUIRED ON EXISTING
 BLOCK WALL THAT WILL BECOME THE NEW
 INTERIOR WALL.
  
 8.)INTERIOR PARTITION (B/A-1) REFERS
 TO AN ANCHOR SCHEDULE THAT IS NOT ON
 THE PAGE.PLEASE SPECIFY ALL
 ATTACHMENTS.
  
 9.)PROVIDE A NOTICE OF COMMENCEMENT
 RECORDED WITH THE CLERK OF COURTS BEFORE
 A PERMIT CAN BE ISSUED.
  
 12.)PROVIDE A SITE PLAN AND A COPY
 OF THE SURVEY OF THIS PROPERTY.
  
 13.)PER FBC 2309.1.8, NOTCHES ON THE
 ENDS OF JOISTS SHALL NOT EXCEED ONE-
 FOURTH THE DEPTH.PLEASE REVISE WALL
 SECTION.
  
 14.)PLEASE REVIEW YOUR SCALE FOR THE
 BOTTOM PLATE (A 2X6 IS DRAWN).ALSO
 PLEASE ADDRESS HOW THE NEW CONCRETE
 THAT YOU ARE ADDING WILL BOND TO THE
 EXISTING.ADDITIONALLY, ADDRESS HOW
 YOU ARE ATTACHING THE REDHEAD INTO THE
 SEAM OF THE NEW AND OLD CONCRETE
  
 15.)THE SKYLIGHT IS REQUIRED TO BE
 PROTECTED.PLEASE ADDRESS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 SAMANTHA THYNG, BUILDING PLANS EXAMINER
 561-659-8096, EXTENSION 8340 OR
 561-805-6724

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-04-14 Cont ID  
Sent By btrobaug Date 2003-04-14 Time 14:24 Rev Time 0.50
Received By btrobaug Date 2003-04-14 Time 14:24 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-04-01 Cont ID  
Sent By sthyng Date 2003-04-14 Time 13:18 Rev Time 0.50
Received By btrobaug Date 2003-03-10 Time 13:12 Sent To B
Notes
2003-03-10 00:00:00PROVISO
 ~~~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 PLEASE PROVIDE THE FOLLOWING
 INFORMATION AND RESUBMIT FOR REVIEW.
  
 PROVIDE A RISER DIAGRAM WITH LOAD
 CALCULATIONS SHOWING ADDITIONAL
 LOADS.SHOW HOW THE NEW 60 AMP PANEL IS
 BEING FED,AND AMPERAGE OF EXISTING SVC.
  
 ADD RECEPTACLES TO COMPLY WITH 210-52.
  
 NOTE THE WATER HEATER IN THE CLOSET MUST
 COMPLY WITH 422-17 NEC.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/659-8096 EXT. 8392

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-04-14 Cont ID  
Sent By sthyng Date 2003-04-14 Time 13:16 Rev Time 0.00
Received By sthyng Date 2003-04-14 Time 13:16 Sent To E
Notes
2003-04-14 00:00:00TO BT DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-03-04 Cont ID  
Sent By dpalmer Date 2003-03-04 Time 11:03 Rev Time 0.00
Received By dpalmer Date 2003-03-04 Time 11:03 Sent To E
Notes
2003-03-04 00:00:00TO ELEC INBOX

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-04-14 Cont ID  
Sent By sthyng Date 2003-04-14 Time 17:41 Rev Time 0.50
Received By sthyng Date 2003-04-14 Time 17:41 Sent To  
Notes
2003-04-14 00:00:00PENTAMATION NOT ALLOWING LOG ONS
 REVIEWED & OK BY JOHN LEECH (NO REVIEW
 REQUIRED; SPLIT UNIT ONLY NO DUCTWORK)

Review Stop Z ZONING
Rev No 1 Status N Date 2003-04-15 Cont ID  
Sent By sthyng Date 2003-04-02 Time 17:21 Rev Time 0.00
Received By sthyng Date 2003-04-15 Time 08:08 Sent To  
Notes
2003-04-15 00:00:00NO ZONING PER DP, EX FOOTPRINT