| 2003-04-07 00:00:00 | BUILDING PLAN REVIEW |
| | *******DENIED******* |
| | ROBERT BROWN(561) 659 8096 EXT 8499 |
| | |
| | MODEL B |
| | |
| | FBC = FLORIDA BUILDING CODE 2001 |
| | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) |
| | |
| | 1) BOUNDARY LINE SURVEY.THE DRAWING |
| | SHALL BE AMENDED TO SHOW THE EGRESS |
| | EASEMENT REQUIRED ON THE ADJACENT LOT |
| | (LOT 22), TO ALLOW SAFE SECONDARY EGRESS |
| | FROM BEDROOM 2 (VIA THE ATRIUM) OF THE |
| | HOME ON LOT 21. |
| | |
| | 2) BOUNDARY LINE SURVEY. IF THE ADJACENT |
| | LOT 20 REQUIRES AN EASEMENT ON LOT 21, |
| | FOR SECONDARY EGRESS FROM BEDROOMS, THEN |
| | THE EGRESS EASEMENT MUST BE SHOWN ON THE |
| | SURVEY DRAWING FOR THIS LOT AND THAT OF |
| | LOT 20. |
| | |
| | 3) SHEET S-1, ROOF FRAMING PLAN.NO |
| | TRUSS ANCHORS ARE SPECIFIED ALONG THE |
| | FAMILY ROOM WALL. |
| | |
| | 4) SHEET S-1, ROOF FRAMING PLAN.ADD A |
| | KEY, FOR THE TRUSS ANCHOR REFERENCE |
| | ANNOTATION, TO CONFIRM IF1MEANS |
| | CONNECTOR MARK 1, AND IF 'U' IS THE |
| | DESIGN UPLIFT CAPACITY REQUIRED.WHAT |
| | IS THE VALUE STATED AS 'R', IS IT THE |
| | REQUIRED LATERAL LOAD CAPACITY (EITHER |
| | F1 OR F2)? |
| | |
| | 5) SHEET S-2, CONNECTOR SCHEDULE.AMEND |
| | THE SCHEDULE TO INCLUDE THE UPLIFT AND |
| | THE LATERAL LOAD CAPACITY FOR THE |
| | SELECTED ANCHORS AND LUMBER GRADE. |
| | |
| | 6) FBC TABLE 600THE GLASS BLOCK WINDOW |
| | IS ON THE PROPERTY LINE.AMEND THE |
| | PLANS TO SHOW THE REQUIREMENT FOR A ONE- |
| | HOUR FIRE-RATED ASSEMBLY. |
| | |
| | 7) SHEET S3, PLYWOOD NAILING DETAIL. |
| | AMEND '10/32 CDX PLYWOOD' TO READ |
| | '19/32 CDX PLYWOOD'. |
| | |
| | 8) PROVISO - ROOF TILE PRODUCT APPROVAL |
| | NOA# 99-1012.02 HAS EXPIRED.SUBMIT A |
| | CURRENT PRODUCT APPROVAL. |
| | |
| | 9) PROVISO - OUTSWING STEEL DOUBLE DOOR |
| | PRODUCT APPROVAL NOA# 99-0311.03 HAS |
| | EXPIRED.SUBMIT A CURRENT PRODUCT |
| | APPROVAL. |
| | |
| | 10) PROVISO - ALUMINUM SLIDING GLASS |
| | DOOR PRODUCT APPROVAL NOA# 98-1228.01 |
| | HAS EXPIRED.SUBMIT A CURRENT PRODUCT |
| | APPROVAL. |
| | |
| | 11) PROVISO - ALUMINUM TUBE MULLION |
| | PRODUCT APPROVAL NOA# 99-0310.01 HAS |
| | EXPIRED.SUBMIT A CURRENT PRODUCT |
| | APPROVAL. |
| | |
| | 12) PROVISO - SINGLE HUNG WINDOW PRODUCT |
| | APPROVAL NOA# 98-1222.02 HAS EXPIRED. |
| | SUBMIT A VALID PRODUCT APPROVAL. |
| | |
| | **QUOTE PERMIT# ON ALL CORRESPONDENCE** |
| | |
| | END OF REVIEW COMMENTS |
| | THE CODE REFERENCES GIVE ADDITIONAL INFO |
| | IF YOU HAVE ANY QUESTIONS PLEASE CALL: |
| | ROBERT BROWN(561) 659 8096 EXT 8499 |