Plan Review Details - Permit 03022105
Plan Review Stops For Permit 03022105
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2003-04-28 Cont ID  
Sent By sthyng Date 2003-04-28 Time 11:48 Rev Time 0.75
Received By sthyng Date 2003-04-28 Time 11:48 Sent To  
Notes
2003-04-28 00:00:00ENGINEER'S DETAIL TO CLARIFY # OF BARS
 REQUIRED IN FIRE WALL

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2003-04-15 Cont ID  
Sent By sthyng Date 2003-04-28 Time 11:47 Rev Time 0.50
Received By sthyng Date 2003-04-15 Time 16:28 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-04-09 Cont ID  
Sent By shernand Date 2003-04-15 Time 15:06 Rev Time 2.50
Received By sthyng Date 2003-04-09 Time 17:24 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-02-28 Cont ID  
Sent By shernand Date 2003-04-07 Time 12:28 Rev Time 4.50
Received By sthyng Date 2003-02-27 Time 15:04 Sent To  
Notes
2003-02-27 00:00:00**********CORRECTIONS************
  
 1.)PREINSPECTION REQUIRED, ALL TRADES.
 CALL 659-8096 EXT 8404 TO SCHEDULE.
  
 2.)ENGINEER TO VERIFY THE INTEGRITY
 OF THE EXISTING FIRE WALL.
  
 3.)RE: SECTION A-A, 5/8" TYPE X GYPSUM
 WALLBOARD REQUIRED AT EACH SIDE OF THE
 FIRE WALL AS PER FBC704.4.2.
  
 4.)DOUBLE 30# UNDERLAYMENT REQUIRED
 FOR ROOF AS PER FBC 1507.3.8.
  
 5.)NAILING OF SHEATHING IN ZONE 3
 (EDGE)TO BE 4" EDGES AND 6" INTERMEDIATE
 AS PER WPB AMENDMENTS TO THE FLORIDA
 BUILDING CODE.
  
 6.)PRODUCT APPROVALS ARE REQUIRED
 FOR THE WINDOW MULLIONS AND THE ROOF
 COVERING.PLEASE SUBMIT TWO COPIES OF
 EACH.
  
 7.)CLARIFY NUMBER OF BOLTS REQUIRED
 FOR WALL FRAMING - 6' OC MINIMUM.ALSO
 REQUIRES 7" EMBEDMENT PER FBC 2307.1.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 LEA SMITH OR SAMANTHA THYNG
 561-659-8096, EXTENSION 8340
  
 REVIEWED 2/27/03 BY LEA SMITH

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2003-04-28 Cont ID  
Sent By sthyng Date 2003-04-28 Time 11:47 Rev Time 0.00
Received By sthyng Date 2003-04-28 Time 11:47 Sent To B
Notes
2003-04-28 00:00:00TO ST DESK

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-04-15 Cont ID  
Sent By shernand Date 2003-04-15 Time 15:06 Rev Time 0.00
Received By shernand Date 2003-04-15 Time 15:06 Sent To B
Notes
2003-04-15 00:00:00STHYNG DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-04-07 Cont ID  
Sent By shernand Date 2003-04-07 Time 12:28 Rev Time 0.00
Received By shernand Date 2003-04-07 Time 12:28 Sent To B
Notes
2003-04-07 00:00:00STHYNG DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-04-04 Cont ID  
Sent By shernand Date 2003-04-04 Time 15:05 Rev Time 0.00
Received By shernand Date 2003-04-04 Time 15:03 Sent To B
Notes
2003-04-04 00:00:00STHYNG DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-02-27 Cont ID  
Sent By dpalmer Date 2003-02-27 Time 13:57 Rev Time 0.00
Received By dpalmer Date 2003-02-27 Time 13:57 Sent To B
Notes
2003-02-27 00:00:00TO MISC INBOX