Plan Review Details - Permit 03022040
| Plan Review Stops For Permit 03022040 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2003-03-28 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2003-03-28 |
Time |
13:22 |
Rev Time |
0.75 |
| Received By |
lsmith |
Date |
2003-03-28 |
Time |
13:22 |
Sent To |
|
|
| Notes |
| 2003-03-28 00:00:00 | PROVISO: NEED INFORMATION FOR MULLINS | | | SUBMITTED BEFORE INSPECTION. | | | NEED DETAILS FOR STORAGE OF STORM PANELS | | | AND METHOD OF INSTALLATION OF 2ND FLOOR | | | STORM PANELS BEFORE C/O. | | | | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 805-6713 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2003-04-01 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-04-01 |
Time |
11:48 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2003-03-05 |
Time |
13:27 |
Sent To |
Z |
|
| Notes |
| 2003-04-01 00:00:00 | PROVISO | | | ~~~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | TO THE PLANS AND RESUBMIT FOR REVIEW | | | PRIOR TO CALLING ROUGH ELECTRICAL | | | INSPECTION. | | | | | | 1} INDICATE THE SIZE OF THE RISER MAST | | | AND WIRE TYPE AND SIZE.NOTE THE SERVICE | | | MUST BE AT LEAST 250 AMPS,#4/0 PER | | | 310-15 (B)(6). | | | | | | 2} THE SIZE OF THE GROUNDING ELECTRODE | | | CONDUCTOR MUST COMPLY WITH 250-66.(#2 | | | FOR #4/0 FEEDERS.) | | | | | | 3} THE GROUNDING ELECTRODE SYSTEM MUST | | | COMPLY WITH 250-50(A)(2). TWO GROUND | | | RODS. | | | | | | 4} PANEL SCHEDULES MUST COMPLY WITH | | | 220-16(A) FOR SMALL APPLIANCES,2@1500 | | | VA. | | | | | | 5} THE LAUNDRY CIRCUIT MUST COMPLY WITH | | | 220-16(B),1500 VA.PLEASE ADD CORRECT | | | CALCULATIONS TO PANEL SCHEDULES AND | | | RECALCULATE LOADS. | | | | | | 6} PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW EQUIPMENT BEING INSTALLED. | | | MAINS/PANELS/BREAKERS MUST BE RATED FOR | | | THE AVAILABLE FAULT CURRENT PER 110-9. | | | | | | 7} PLEASE LIST THE REQ'D ARC | | | FAULT PROTECTED CIRCUITS ON PANEL | | | SCHEDULE OR NOTE ON PLANS FOR BRANCH | | | CIRCUIT PROTECTION. PER 210-12 | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/659-8096 EXT. 8392 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-02-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-02-26 |
Time |
12:26 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2003-02-26 |
Time |
12:26 |
Sent To |
E |
|
| Notes |
| 2003-02-26 00:00:00 | TO ELEC INBOX. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2003-03-31 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-03-31 |
Time |
14:47 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2003-03-31 |
Time |
14:47 |
Sent To |
P |
|
| Notes |
| 2003-03-31 00:00:00 | MECHANICAL PERMIT 03022042 | | | EXACT CHANGE OUT - NO CHANGE IN DUCTWORK |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2003-04-01 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-03-31 |
Time |
14:48 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2003-04-01 |
Time |
11:47 |
Sent To |
E |
|
| Notes |
| 2003-04-01 00:00:00 | NO PLUMBING PLANS SUBMITTED FOR REVIEW |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2003-04-09 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-04-01 |
Time |
13:56 |
Rev Time |
0.00 |
| Received By |
kmcvey |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy