Plan Review Details - Permit 03022040
Plan Review Stops For Permit 03022040
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2003-03-28 Cont ID  
Sent By lsmith Date 2003-03-28 Time 13:22 Rev Time 0.75
Received By lsmith Date 2003-03-28 Time 13:22 Sent To  
Notes
2003-03-28 00:00:00PROVISO: NEED INFORMATION FOR MULLINS
 SUBMITTED BEFORE INSPECTION.
 NEED DETAILS FOR STORAGE OF STORM PANELS
 AND METHOD OF INSTALLATION OF 2ND FLOOR
 STORM PANELS BEFORE C/O.
  
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 805-6713

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-04-01 Cont ID  
Sent By kstevens Date 2003-04-01 Time 11:48 Rev Time 1.00
Received By btrobaug Date 2003-03-05 Time 13:27 Sent To Z
Notes
2003-04-01 00:00:00PROVISO
 ~~~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 TO THE PLANS AND RESUBMIT FOR REVIEW
 PRIOR TO CALLING ROUGH ELECTRICAL
 INSPECTION.
  
 1} INDICATE THE SIZE OF THE RISER MAST
 AND WIRE TYPE AND SIZE.NOTE THE SERVICE
 MUST BE AT LEAST 250 AMPS,#4/0 PER
 310-15 (B)(6).
  
 2} THE SIZE OF THE GROUNDING ELECTRODE
 CONDUCTOR MUST COMPLY WITH 250-66.(#2
 FOR #4/0 FEEDERS.)
  
 3} THE GROUNDING ELECTRODE SYSTEM MUST
 COMPLY WITH 250-50(A)(2). TWO GROUND
 RODS.
  
 4} PANEL SCHEDULES MUST COMPLY WITH
 220-16(A) FOR SMALL APPLIANCES,2@1500
 VA.
  
 5} THE LAUNDRY CIRCUIT MUST COMPLY WITH
 220-16(B),1500 VA.PLEASE ADD CORRECT
 CALCULATIONS TO PANEL SCHEDULES AND
 RECALCULATE LOADS.
  
 6} PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW EQUIPMENT BEING INSTALLED.
 MAINS/PANELS/BREAKERS MUST BE RATED FOR
 THE AVAILABLE FAULT CURRENT PER 110-9.
  
 7} PLEASE LIST THE REQ'D ARC
 FAULT PROTECTED CIRCUITS ON PANEL
 SCHEDULE OR NOTE ON PLANS FOR BRANCH
 CIRCUIT PROTECTION. PER 210-12
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/659-8096 EXT. 8392

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-02-26 Cont ID  
Sent By dpalmer Date 2003-02-26 Time 12:26 Rev Time 0.00
Received By dpalmer Date 2003-02-26 Time 12:26 Sent To E
Notes
2003-02-26 00:00:00TO ELEC INBOX.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-03-31 Cont ID  
Sent By pkrauss Date 2003-03-31 Time 14:47 Rev Time 0.35
Received By pkrauss Date 2003-03-31 Time 14:47 Sent To P
Notes
2003-03-31 00:00:00MECHANICAL PERMIT 03022042
 EXACT CHANGE OUT - NO CHANGE IN DUCTWORK

Review Stop P PLUMBING
Rev No 1 Status N Date 2003-04-01 Cont ID  
Sent By pkrauss Date 2003-03-31 Time 14:48 Rev Time 0.33
Received By kstevens Date 2003-04-01 Time 11:47 Sent To E
Notes
2003-04-01 00:00:00NO PLUMBING PLANS SUBMITTED FOR REVIEW

Review Stop Z ZONING
Rev No 1 Status N Date 2003-04-09 Cont ID  
Sent By btrobaug Date 2003-04-01 Time 13:56 Rev Time 0.00
Received By kmcvey Date   Time   Sent To  
Notes
***NONE***