Plan Review Details - Permit 03021755
Plan Review Stops For Permit 03021755
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-04-09 Cont ID  
Sent By hmoser Date 2003-04-10 Time 07:14 Rev Time 2.25
Received By jwitmer Date 2003-04-09 Time 16:13 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-03-27 Cont ID  
Sent By sthyng Date 2003-04-07 Time 20:09 Rev Time 2.00
Received By jwitmer Date 2003-03-27 Time 14:36 Sent To  
Notes
2003-03-27 00:00:00BUILDING PLAN REVIEW
 PERMIT: 03021755
 ADD: 211 LINDA LANE
 CONT: JAMES L COLE
 TEL: (561)252-3467
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1) PLANS, SPECIFICATIONS,REPORTS OR
 OTHER DOCUMENTS PREPARED BY THE DESIGN
 PROFESSIONAL AND BEING FILED FOR PUBLIC
 RECORD SHALL HAVE THE SIGNATURE AND
 SEAL OF THE DESIGN PROFESSIONAL AFFIXED
 TO THE DOCUMENT.
 FL STATE STAT: 61G15-23.002 ENGINEERS
 FL ATATE STAT: 61G16.003 ARCHITECTS
 SOILS REPORT NOT ORIGINAL SIGNATURE,
 ALSO REQUIRES SEAL.
  
 2)2001 FL BLD CODE, 1005.4:
 PROVIDE EMERGENCY EGRESS WINDOWS IN
 SLEEPING ROOMS WITH A MINIMUM NET CLEAR
 OPENING HEIGTH OF 24" AND NET CLEAR
 OPENING WIDTH OF 20" AND A NET CLEAR
 OPENING AREA OF 5.7 SQ.FT. GROUND FLOOR
 OPENINGS ARE PERMITTED TO HAVE A NET
 CLEAR OPENING OF 5.0 SQ. FT. SILL HEIGTH
 SHALL NOT BE MORE THAN 44 " ABOVE THE
 FINISH FLOOR.
 PLEASE PROVIDE ADDITIONAL INFORMATION
 FOR CASEMENT WINDOWS, WINDOW TYPE (B)
 IS THIS A SINGLE OR DOUBLE CASEMENT WIN-
 DOW?
 PROVIDE INFORMATION FOR CASEMENT WIN-
 DOW (C) A 2'-0" WIDE WINDOW. CLEAR WIN-
 DOW WIDTH FOR EGRESS WINDOWS SHALL BE
 20".
  
 3) 1606.1 TRUSS LAYOUT PLAN W/ TRUSS &
 GIRDER LOADS, VERTICAL, HORIZONTAL &
 GRAVITY.
  
 4) 1707.3.1 JOIST HANGERS, FRAMING
 ANCHORS & SIMILAR DEVICES SHALL BE TEST-
 ED IN ACCORDANCE W/ ASTM D 1761 & BE
 LABELED AND LISTED FOR THEIR LOAD CARRY-
 ING CAPACITY.PROVIDE AN ANCHOR SCHEDULE.
  
 5)FL BLD CODE 104.2.1.2
 ADDITIONAL INFORMATION REQUIRED,
 2ND FLOOR PLAN INDICATES THE USE OF
 2X8 WALL MEMBERS, WILL THIS BE ON ONLY
 THE DESIGNATED HASHED WALLS? WILL THE
 REMAINDER OF THE EXTERIOR WALLS BE 2X6
 AS INDICATED ON THE TYPICAL WALL
 SECTION?
  
 6)2305.2.2 FLOOR/CEILING ASSEMBLIES
 SINGLE FAMILY DWELLINGS. IN FLOOR/CEIL/
 ING ASSEMBLIES SEPERATING USEABLE SPACE
 INTO 2 OR MORE APPROXIMATE AREAS WITH NO
 AREA GREATER THAN 500 SQ FT. DRAFTSTOP-
 PING SHALL BE PROVIDED PARALLEL TO THE
 MAIN FRAMING MEMBERS.
  
 7) 1007.3.1 THE SUM OF 2 RISERS + 1
 TREAD SHALL EQUAL BETWEEN 24"- 25".
  
 8)1015.2 HEIGHT. GUARDRAILS SHALL
 FORM A VERTICAL PROTECTIVE BARRIER NOT
 LESS THAN 42" HIGH.
 1015.3 OPENINGS. OPEN GUARDRAILS
 SHALL HAVE INTERMEDIATE RAILS OR ORNA-
 MENTAL PATTERNS SUCH AS A 4" DIAMETER
 SPHERE CAN NOT PASS THROUGH. A BOTTOM
 RAIL OR CURB SHALL BE PROVIDED THAT WILL
 REJECT THE PASSAGE OF 2" DIAMETER
 SPHERE.
 PROVIDE DETAIL OF GUARDRAIL FOR THE
 2ND FLOOR LANDING, MISSING INFO.
  
 9) FL BLD CODE 2309.6 ATTIC ACCESS, PRO-
 VIDE ATTIC ACCESS 20"X36".
  
 10) FIGURE 1606 WIND-BORNE DEBRIS
 REGION; INDICATES THAT W.P.B. CITY OF IS
 LOCATED IN THE 140 MPH ZONE. PLANS ARE
 TO INDICATE THIS.
 S-1 "DESIGN DATA" (G)INDICATES A
 110 MPH WIND ZONE.
  
 11) 3401.7.1.2 WHERE AN ADDITION IS 25%
 OR MORE OF THE AREA OF THE EXISTING
 BUILDING, THE EXISTING BUILDING AND ADD-
 ITION SHALL BE MADE TO COMPLY WITH ALL
 REQUIREMENTS OF THIS CODE FOR A BUILDING
 OF AREA EQUAL TO THE COMBINED AREA OF
 THE ADDITION AND EXISTING BUILDING.
  
 12) FL. BLD CODE 1606.1.7 THE FOLLOWING
 INFORMATION RELATED TO WIND SHALL BE
 SHOWN ON THE CONSTRUCTION DRAWINGS,
 1)- BASIC WIND SPEED, MPH
 2)- WIND IMPORTANCE FACTOR, & BUILDING
 CATEGORY
 3)- WIND EXPOSURE
 4)- INTERNAL PRESSURE COEFFICIENT,
 5)- COMPONENTS & CLADDING, THE DESIGN
 WIND PRESSURES IN TERMS OF PSF.
  
 12)1606.1.4(1) IN WIND BORNE DEBRIS
 REGIONS, EXTERIOR GLAZING THAT RECEIVES
 POSITIVE PRESSURE IN BUILDINGS SHALL BE
 ASSUMED TO BE OPENINGS UNLESS SUCH
 GLAZING IS IMPACT RESISTANT OR PROTECTED
 WITH AN IMPACT RESISTANT COVERING MEET-
 ING THE REQUIREMENTS OF SSTD 12, ASTM
 E 1886 AND ASTM E 1996 OR MIAMI-DADE.
 1) GLAZED OPENINGS LOCATED WITHIN 30 FT
 OF GRADE SHALL MEET THE REQUIREMENTS OF
 LARGE MISSLE TEST.
  
 13)FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORT, SBCCI OR DADE COUNTY
 REPORT ARE ACCEPTED. MISSING REPORTS:
 A) CASEMENT WINDOWS
 B) STORM SHUTTERS
 C) ROOFING REPORT- FLAT ROOF
  
 14)PROVIDE STORM PANEL INFORMATION WITH
 INSTALLATION SCHEDULE AND KEY PLAN WITH
 SPECIFIC ANCHORS AND MOUNTING TO BE USED
 FOR ALL NON-IMPACT GLAZING.
 FBC 1606.1.4.
  
 15)FL BLD CODE 2001 SECTION 103.6,
 1606.1.4, 1707.4 & 3401.7.2.4.
 PROCEDURES: 1(B) A COMPLETE INSTALLATION
 SCHEDULE SUMMARIZING & IDENTIFYING
 OPENING SIZES, STORY HEIGHTS, UNIT MARK
 NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM
 BAR REINFORCING REQUIREMENTS, WALL PRES-
 SURE ZONES, SLAT TYPES, ETC., SHALL BE
 SUBMITTED AT TIME OF PERMIT APPLICATION
 TO FACILITATE PLAN REVIEW AND PERMIT
 ISSUANCE. SEE SAMPLE ANCHOR SCHEDULE!
  
 16) 1606.2.4 MAIN WIND FORCE RESTING
 SYSTEM(MWFRS) ALL ELEMENTS & CONNENC-
 TIONS OF THE (MWFRS) SHALL BE DESIGNED
 FOR VERTICAL AND HORIZONTAL LOADS.
 2 STORY WALL SECTION INDICATES THE FLOOR
 TRUSS SYSTEM ANCHORED TO THE PLATE WITH
 SIMPSON TC 26, HOW WILL THE FLOOR TRUSS
 SYSTEM BE TIED WITH A CONTINUOUS LOAD
 PATH TO THE FRAME WALL AT THE BOTTOM
 PLATE? AT TOP PLATE?
  
 17) SINGLE STORY WALL SECTION INDICATES
 A 14" HEIGHT OF THE FOOTER,
 1804.1.3 THE BOTTOM OF THE FOUNDA-
 TION SHALL EXTEND NO LESS THAN 12"
 BELOW FINISH GRADE.
 1909.1 MINIMUM SLAB THICKNESS ON GRADE
 IS 3 1/2".
 THE TOTAL OF 12"+3 1/2"= 15 1/2" TOTAL
 HEIGHT!
  
 18)FL BLD CODE 2405.2 HAZARDOUS LOCATION
 PROVIDE SAFETY GLASS FOR THIS LOCATION:
 MASTER BATH TUB!
  
 19)2504.2.2 INSTALLATION OF EXTERIOR
 LATHING AND FRAMING SHALL COMPLY WITH
 ASTM C-1063. HI-RIB LATH NAILED @ 4"OC,
 HI-RIB NAILED HORIZONTALLY REQUIRES
 NAILS TO BE EMBEDDED INTO THE FRAMING
 MEMBER A MINIMUM OF 1 3/4".
  
 20)BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH
 THE PLANS WHEN RESUBMITTING PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN
 BE FOUND, WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
 JIM WITMER
 BUILDING PLAN REVIEW
 TEL: (561)659-8096 X 8412
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2003-05-22 Cont ID  
Sent By btrobaug Date 2003-05-22 Time 10:55 Rev Time 1.00
Received By btrobaug Date 2003-05-22 Time 10:24 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-04-09 Cont ID  
Sent By shernand Date 2003-05-22 Time 10:07 Rev Time 0.33
Received By dpalmer Date 2003-04-09 Time 06:51 Sent To M
Notes
2003-04-09 00:00:00********** NOTES/PROVISO *************
  
 PLANS ARE TO HAVE ALL PREVIOUS NOTES
 ADDRESSED AND PLANS ARE TO BE RE-PRINTED
 BEFORE ROUGHINSPECTION.
 PLANS NEED TO CORRELATE .
  
 IF THERE ARE ANY QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372
 [email protected].

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2003-04-03 Cont ID  
Sent By shernand Date 2003-04-08 Time 13:14 Rev Time 0.75
Received By dpalmer Date 2003-04-03 Time 07:06 Sent To M
Notes
2003-04-03 00:00:00************ UNSAT *************
  
 PLEASE SEE BOTH SETS OF PLANS. PLANS
 DO NOTE CORRELATE, ONE SHOWS MORE RECEPT
 -S/LTS, SW RECEPTS ETC.
  
 1)NOTE: PLEASE HAVE PLANS REPRINTED
 AND ALL CHANGES MADE TO PLANS. PLEASE
 NOTE, CHANGES AN NOT BE DRAWN ON PLANS
 UNLESS DONE BY ARCH OF RECORD AND "EACH"
 CHANGE WOULD HAVE TO BE INITIALED,DATED
 BY ARCH OF RECORD. FS 481
  
 2)NOTE: PLEASE LIST THE REQ`D BATH
 CIRCUIT(S) ON PANEL SCHEDULE AS ON FIRST
 REVIEW NOTES.
  
 3)NOTE: PLEASE SEE FS 553.80(2)(B) FOR
 PLANS AND DESIGN PROFESSIONAL.
  
  
 PLEASE REPRINT AND HAVE PLANS SIGNED AND
 SEALED BY THE ARCH OF RECORD 481.221
 AND SUBMIT FOR REVIEW.
 IF THERE ARE ANY QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2003-03-12 Cont ID  
Sent By sthyng Date 2003-03-31 Time 16:13 Rev Time 0.50
Received By dpalmer Date 2003-03-12 Time 17:49 Sent To P
Notes
2003-03-12 00:00:00************ UNSAT ****************
  
 1)NOTE: PLEASE CLARIFY EXISTING ELECT-
 RICAL.SHOW AS (E).
 RECEPT SPACING ETC.210-52
 FRONT AND REAR RECEPTS. 210-52E
  
 2)NOTE: SD`S REQ`D ON FIRST FLOOR
 LEADING TO LEVEL ABOVE AND PLEASE
 INCLUDE SD INSIDE AND OUTSIDE EXIST
 LOWER BEDROOM. NFPA-72 8-1.4.2
  
 3)NOTE: PLANS SHOW A MAIN DISC NEXT
 TO METER AND RISER SHOWS COMING FROM
 METER INTO A MCB PANEL? PLEASE CORRELATE
  
 4)NOTE: IF SERVICE IS NEW? PLEASE
 SUBMIT AIC RATING FOR NEW MAIN /MCB
 110-9
  
 5)NOTE: PLEASE LIST THE REQ`D DEDICATED
 BATH CIRCUIT(S) PER 210-52D,210-11-C-3
  
 6)NOTE: PLANS REFERENCES PALM BEACH
 COUNTY EDITION OF FBC? PLEASE NOTE,
 2001 FBC. W/ CITY OF WEST PLAM BEACH
 AMENDMENTS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2003-05-22 Cont ID  
Sent By shernand Date 2003-05-22 Time 10:06 Rev Time 0.00
Received By shernand Date 2003-05-22 Time 10:06 Sent To E
Notes
2003-05-22 00:00:00REVISION, BT DESK, DP ON VACATION.

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2003-05-05 Cont ID  
Sent By shernand Date 2003-05-05 Time 14:58 Rev Time 0.00
Received By shernand Date 2003-05-05 Time 14:58 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-04-08 Cont ID  
Sent By shernand Date 2003-04-08 Time 13:14 Rev Time 0.00
Received By shernand Date 2003-04-08 Time 13:14 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-04-07 Cont ID  
Sent By sthyng Date 2003-04-07 Time 20:09 Rev Time 0.00
Received By sthyng Date 2003-04-07 Time 20:09 Sent To B
Notes
2003-04-07 00:00:00TO JW DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-03-31 Cont ID  
Sent By sthyng Date 2003-03-31 Time 16:12 Rev Time 0.00
Received By sthyng Date 2003-03-28 Time 16:14 Sent To E
Notes
2003-03-31 00:00:00TO BT DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-02-25 Cont ID  
Sent By dpalmer Date 2003-02-25 Time 09:11 Rev Time 0.00
Received By dpalmer Date 2003-02-25 Time 09:11 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 4 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By pkrauss Date 2003-05-06 Time 15:39 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2003-04-10 Cont ID  
Sent By shernand Date 2003-05-05 Time 14:58 Rev Time 0.25
Received By hmoser Date 2003-04-10 Time 07:26 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2003-04-07 Cont ID  
Sent By hmoser Date 2003-04-07 Time 16:46 Rev Time 0.50
Received By hmoser Date 2003-04-07 Time 16:46 Sent To B
Notes
2003-04-07 00:00:00PLAN DENIED
 1) NEED RETURN AIR DUCT SIZE
 2) NEED EXHAUEST FAN FOR MASTER BATH
 FBC.SECTION 402.3.1
 3) WHERE ARE A/C DUCTS ON 1ST.FLOOR
 COMING FROM
 PLAN REVIEW BY HAROLD MOSER
 (651)659-8096 EXT.8221

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2003-03-12 Cont ID  
Sent By dpalmer Date 2003-04-03 Time 07:41 Rev Time 0.50
Received By jleech Date 2003-03-12 Time 19:35 Sent To B
Notes
2003-03-12 00:00:00NO A/C FLOOR PLAN.

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-03-12 Cont ID  
Sent By dpalmer Date 2003-03-12 Time 17:49 Rev Time 0.33
Received By jleech Date 2003-03-12 Time 19:34 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-03-04 Cont ID  
Sent By dpalmer Date 2003-02-25 Time 09:11 Rev Time 0.00
Received By sgraham Date   Time   Sent To P
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved