Plan Review Details - Permit 03021562
Plan Review Stops For Permit 03021562
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2003-07-15 Cont ID  
Sent By sthyng Date 2003-07-15 Time 13:42 Rev Time 0.50
Received By sthyng Date 2003-07-15 Time 13:42 Sent To  
Notes
2003-07-15 00:00:00*******CORRECTIONS*******
  
 1.)THE PLAN SHOWS A LANDING OF 5'.
 GUARDRAIL ONE DOES NOT SHOW THIS
 LANDING.CLEARLY SHOW ON THE SHOP
 DRAWINGS OF THE GUARDRAIL THE MIN. 60"
 REQUIRED FOR LANDINGS FBC11-4.8.4.
  
 2.)THE ORIGINAL PLAN SHOWS A 1'6"
 EXTENSION OF THE GUARDRAIL (ONE) AT THE
 TOP AND BOTTOM OF THE GUARDRAIL.THE
 SHOP DRAWINGS HAVE REDUCED THIS TO
 1'4" AND 1'5 1/2".A MINIMUM OF 18"
 IS REQUIRED FBC11-4.8.5(2).
  
 3.)THE DIMENSION FOR HANDICAP RAMP
 TWO WAS REVISED TO BE 34" (FROM 32"),
 BUT THE DIMENSIONS ON THE OTHER SIDE
 OF THE DETAIL (20" AND 1') WERE NOT
 CHANGED.
  
 4.)THE ORIGINAL PLAN BY LCA
 ARCHITECTURE, INC. STATES ON SHEET A3:
 "RAIL NOTE: CONTRACTOR SHALL PROVIDE
 RAIL ENGINEERING & SHOP DRAWINGS FOR
 APPROVAL."HAVE THE ARCHITECT REVIEW
 THE SHOP DRAWINGS.
  
 5.)THE GUARDRAIL IS TO COMPLY WITH
 FBC1608.2.
  
 SAMANTHA THYNG, BUILDING PLANS EXAMINER
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2003-06-09 Cont ID  
Sent By shernand Date 2003-07-15 Time 09:42 Rev Time 1.00
Received By sthyng Date 2003-06-09 Time 09:37 Sent To  
Notes
2003-06-09 00:00:00******CORRECTIONS*******
  
 SAMANTHA THYNG, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)FBC 11-4.8.5(5); TOP OF HANDRAIL
 GRIPPING SURFACES SHALL BE MOUNTED
 BETWEEN 34 INCHES AND 38 INCHES ABOVE
 RAMP SURFACES.32" IS SHOWN.
  
 2.)SUBMITTALS MUST BE MADE FOR ALL
 THREE PERMITS.THE OTHER TWO PERMIT
 NUMBERS ARE 03021510 AND 03021564.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2003-02-26 Cont ID  
Sent By shernand Date 2003-06-06 Time 15:28 Rev Time 1.00
Received By sthyng Date 2003-02-26 Time 08:26 Sent To  
Notes
2003-02-26 00:00:00REVIEWED BY LS (SAME PLAN AS FOR PERMIT
 03021510 AND 03021564) - OK
 2/26/03

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-07-15 Cont ID  
Sent By shernand Date 2003-07-15 Time 09:42 Rev Time 0.00
Received By shernand Date 2003-07-15 Time 09:42 Sent To B
Notes
2003-07-15 00:00:00ST DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-06-06 Cont ID  
Sent By shernand Date 2003-06-06 Time 15:28 Rev Time 0.00
Received By shernand Date 2003-06-06 Time 15:28 Sent To B
Notes
2003-06-06 00:00:00STHYNG DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-02-21 Cont ID  
Sent By dpalmer Date 2003-02-21 Time 12:56 Rev Time 0.00
Received By dpalmer Date 2003-02-21 Time 12:56 Sent To Z
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-02-24 Cont ID  
Sent By dpalmer Date 2003-02-21 Time 12:56 Rev Time 0.00
Received By sgraham Date   Time   Sent To B
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy