Plan Review Details - Permit 03021562
| Plan Review Stops For Permit 03021562 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2003-07-15 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-07-15 |
Time |
13:42 |
Rev Time |
0.50 |
| Received By |
sthyng |
Date |
2003-07-15 |
Time |
13:42 |
Sent To |
|
|
| Notes |
| 2003-07-15 00:00:00 | *******CORRECTIONS******* | | | | | | 1.)THE PLAN SHOWS A LANDING OF 5'. | | | GUARDRAIL ONE DOES NOT SHOW THIS | | | LANDING.CLEARLY SHOW ON THE SHOP | | | DRAWINGS OF THE GUARDRAIL THE MIN. 60" | | | REQUIRED FOR LANDINGS FBC11-4.8.4. | | | | | | 2.)THE ORIGINAL PLAN SHOWS A 1'6" | | | EXTENSION OF THE GUARDRAIL (ONE) AT THE | | | TOP AND BOTTOM OF THE GUARDRAIL.THE | | | SHOP DRAWINGS HAVE REDUCED THIS TO | | | 1'4" AND 1'5 1/2".A MINIMUM OF 18" | | | IS REQUIRED FBC11-4.8.5(2). | | | | | | 3.)THE DIMENSION FOR HANDICAP RAMP | | | TWO WAS REVISED TO BE 34" (FROM 32"), | | | BUT THE DIMENSIONS ON THE OTHER SIDE | | | OF THE DETAIL (20" AND 1') WERE NOT | | | CHANGED. | | | | | | 4.)THE ORIGINAL PLAN BY LCA | | | ARCHITECTURE, INC. STATES ON SHEET A3: | | | "RAIL NOTE: CONTRACTOR SHALL PROVIDE | | | RAIL ENGINEERING & SHOP DRAWINGS FOR | | | APPROVAL."HAVE THE ARCHITECT REVIEW | | | THE SHOP DRAWINGS. | | | | | | 5.)THE GUARDRAIL IS TO COMPLY WITH | | | FBC1608.2. | | | | | | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2003-06-09 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-07-15 |
Time |
09:42 |
Rev Time |
1.00 |
| Received By |
sthyng |
Date |
2003-06-09 |
Time |
09:37 |
Sent To |
|
|
| Notes |
| 2003-06-09 00:00:00 | ******CORRECTIONS******* | | | | | | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)FBC 11-4.8.5(5); TOP OF HANDRAIL | | | GRIPPING SURFACES SHALL BE MOUNTED | | | BETWEEN 34 INCHES AND 38 INCHES ABOVE | | | RAMP SURFACES.32" IS SHOWN. | | | | | | 2.)SUBMITTALS MUST BE MADE FOR ALL | | | THREE PERMITS.THE OTHER TWO PERMIT | | | NUMBERS ARE 03021510 AND 03021564. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2003-02-26 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-06 |
Time |
15:28 |
Rev Time |
1.00 |
| Received By |
sthyng |
Date |
2003-02-26 |
Time |
08:26 |
Sent To |
|
|
| Notes |
| 2003-02-26 00:00:00 | REVIEWED BY LS (SAME PLAN AS FOR PERMIT | | | 03021510 AND 03021564) - OK | | | 2/26/03 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-07-15 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-07-15 |
Time |
09:42 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-07-15 |
Time |
09:42 |
Sent To |
B |
|
| Notes |
| 2003-07-15 00:00:00 | ST DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-06-06 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-06 |
Time |
15:28 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-06-06 |
Time |
15:28 |
Sent To |
B |
|
| Notes |
| 2003-06-06 00:00:00 | STHYNG DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-02-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-02-21 |
Time |
12:56 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2003-02-21 |
Time |
12:56 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-02-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-02-21 |
Time |
12:56 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
B |
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy