| Plan Review Stops For Permit 03021085 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2004-08-06 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-08-06 |
Time |
11:27 |
Rev Time |
0.66 |
| Received By |
alange |
Date |
2004-08-06 |
Time |
11:27 |
Sent To |
E |
|
| Notes |
| 2004-08-06 00:00:00 | RESTAMP LOST PLANSOK TO ELEC. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2004-06-10 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-05 |
Time |
11:03 |
Rev Time |
0.66 |
| Received By |
alange |
Date |
2004-06-10 |
Time |
09:56 |
Sent To |
|
|
| Notes |
| 2004-06-10 00:00:00 | REVISION OK ALANGE |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2004-05-27 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-05-27 |
Time |
09:29 |
Rev Time |
0.66 |
| Received By |
alange |
Date |
2004-05-27 |
Time |
09:29 |
Sent To |
Z |
|
| Notes |
| 2004-05-27 00:00:00 | DENIED | | | 1.SHOW REVISED BUILDING ON SITE PLAN. | | | | | | 2.BUILDING VALUATION HAS BEEN CHANGED | | | DUE TO ADDITION SQUARE FEET ADDED. | | | 216 SQ. FT. X $38.48 = $8311.00 | | | ADDITIONAL PERMIT FES ARE DUE. | | | | | | 3.BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | ANY QUESTIONS CALL ME | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2004-04-19 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-05-27 |
Time |
07:14 |
Rev Time |
0.50 |
| Received By |
alange |
Date |
2004-04-19 |
Time |
12:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2004-04-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-04-17 |
Time |
15:32 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2004-04-01 |
Time |
12:38 |
Sent To |
|
|
| Notes |
| 2004-04-01 00:00:00 | DENIED | | | 1.PRODUCT APPROVAL FOR YALE OGRON | | | WINDOW NOT ON THE FBC PRODUCT APPROVAL | | | SITE. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, | | | 2003ARE REQUIRED TO COMPLY WITH THE | | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR | | | INFORMATIONPLEASE SEE THE STATE WEBSITE | | | AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 2.MANY EXTRA PAGES.. ONLY 2 SETS | | | REQUIRED....SEE ALSO PLUMBING NOTES. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2004-03-09 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-04-01 |
Time |
10:44 |
Rev Time |
1.25 |
| Received By |
alange |
Date |
2004-03-09 |
Time |
11:16 |
Sent To |
|
|
| Notes |
| 2004-03-09 00:00:00 | 1. THE NOTICE OF COMMENCEMENT SHALL BE | | | RECORDED AT PALM BEACH COUNTY COURTHOUSE | | | AND A COPY SUBMITTED TO THIS OFFICE | | | BEFORE A PERMIT CAN BE ISSUED.BLANK | | | FORMS ARE AVAILABLE FROM THIS OFFICE. | | | | | | 2.BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | 3.PRODUCT APPROVAL FOR YALE OGRON | | | WINDOW NOT LISTED ON THE FBC PRODUCT | | | APPROVAL SITE. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | 4.SIGN ENERGY CALC'S. | | | ANY QUESTIONS CALL | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
P |
Date |
2005-03-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-03-25 |
Time |
16:28 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2005-03-25 |
Time |
16:28 |
Sent To |
|
|
| Notes |
| 2005-03-25 00:00:00 | PLANS REDLINED. | | | | | | METER/MAIN TO HAVE A 200A MAIN MAX. | | | M/M IS 200A NOT 225A AS SHOWN ON RISER. | | | SEC'S SHOWN AS 2/0'S, 200A MAIN MAX OCP. | | | 310.15B6, 240.4 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
F |
Date |
2005-03-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-03-08 |
Time |
17:34 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2005-03-08 |
Time |
17:34 |
Sent To |
|
|
| Notes |
| 2005-03-08 00:00:00 | ********** UNSAT **************** | | | | | | 1)NOTE: PLEASE SEE PLANS HAVE BEEN | | | REDLINED SINCE THE BEGINING OF PROJECT | | | FOR SEC'S AND SIZE OF EXISTING METER. | | | PLEASE SEE 240.4,310.15B6 FOR MIN SIZE | | | SEC'S FOR A 300A SERVICE. | | | | | | 2)NOTE: PLEASE SEE 250.32 FOR GROUNDING | | | AT DETACHED BLDG.S | | | | | | 3)NOTE: PLEASE SEE LOAD CALCULATIONS | | | HAVE NOW INCREASED FROM ORIGINAL 61A'S | | | TO 91.6A'S | | | PLEASE SUBMIT LOAD CALCULATIONS PER | | | 220.31B | | | | | | 4)NOTE: PLEASE CLARIFY 3-SMALL APPLIANCE | | | CIRCUITS FOR GARAGE? | | | | | | PLEASEBE SURE TO PLACE ON AS LITTLE | | | PAGES AS POSSIBLE, AS REV' FEES ARE | | | BASED ON $10 PER PAGE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2004-08-06 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-08-06 |
Time |
13:53 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-08-06 |
Time |
13:39 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2004-05-13 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-08-06 |
Time |
11:27 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-05-13 |
Time |
09:08 |
Sent To |
P |
|
| Notes |
| 2004-05-13 00:00:00 | REDLINED SEC'S PER 310.15B6 | | | 240.4 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2004-04-28 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-11 |
Time |
09:24 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-04-28 |
Time |
07:04 |
Sent To |
B |
|
| Notes |
| 2004-04-28 00:00:00 | SENT TO BLDG FOR PROCESSING | | | REDLINED FOR SEC'S FOR 300A SEVICE. | | | 310.15B6 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2004-04-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-04-17 |
Time |
15:32 |
Rev Time |
0.60 |
| Received By |
dpalmer |
Date |
2004-04-17 |
Time |
15:31 |
Sent To |
B |
|
| Notes |
| 2004-04-17 00:00:00 | ************** UNSAT ************** | | | | | | 1)NOTE: PLEASE LIST THE REQ'D BATH | | | CIRCUIT ON PANEL SCHEDULE PER 210.52D, | | | 210.11C3 | | | | | | 2)NOTE: PLEASE SEE RISER INDICATES A | | | 300A SERVICE ON A 225A METERCAN. PLEASE | | | VERIFY SIZING OF METERCAN.225A? | | | PLEASE SEE SERVICE IS NOW ADDING A 100A | | | DISC TO EXIST 200A SERVICE. PLEASE | | | SEE 310.15B6 MIN CONDUCTOR SIZE FOR | | | 300A RESDENT SERVICE./ 230.42 | | | | | | 3)NOTE: PLEASE SEE 250.50 AND 250.32 | | | FOR NEW FOOTER STEEL AND COLD WATER | | | AS PART OF THE GROUNDING SYSTEM AT | | | DETACHED BLDG. | | | | | | 4)NOTE: PLEASE SEE PANEL SCHEDULE | | | INDICATES A/C UNIT, BUT NONE SHOWN ON | | | PLANS?? | | | | | | PROVIDE LOAD CALCULATIONS 215.5 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2004-02-09 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-04-16 |
Time |
10:12 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2004-02-09 |
Time |
06:46 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2005-03-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-03-07 |
Time |
10:12 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-03-07 |
Time |
10:12 |
Sent To |
E |
|
| Notes |
| 2005-03-07 00:00:00 | TO DPALMER DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2004-12-10 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2004-12-10 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2004-12-10 |
Time |
14:16 |
Sent To |
Z |
|
| Notes |
| 2004-12-10 00:00:00 | SENT TO "Z" BOX. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2004-08-05 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-08-05 |
Time |
11:03 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-08-05 |
Time |
11:03 |
Sent To |
B |
|
| Notes |
| 2004-08-05 00:00:00 | TO AL DESK/RESTAMP |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2004-05-11 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-05-27 |
Time |
16:01 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-11 |
Time |
09:24 |
Sent To |
E |
|
| Notes |
| 2004-05-11 00:00:00 | TO DP DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2004-04-07 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-07 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-04-07 |
Time |
11:12 |
Sent To |
P |
|
| Notes |
| 2004-04-07 00:00:00 | TO KS BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2004-03-17 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-17 |
Time |
16:41 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-03-17 |
Time |
16:41 |
Sent To |
P |
|
| Notes |
| 2004-03-17 00:00:00 | TO KS BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2004-03-09 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-09 |
Time |
08:39 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-03-09 |
Time |
08:39 |
Sent To |
B |
|
| Notes |
| 2004-03-09 00:00:00 | TO AL DESK/PER LM |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2004-03-05 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-03-08 |
Time |
09:06 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-03-05 |
Time |
07:57 |
Sent To |
Z |
|
| Notes |
| 2004-03-05 00:00:00 | TO ANGELA FOR APPROVAL PER MM |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-04-28 |
|
|
Cont ID |
|
| Sent By |
ptjomsto |
Date |
2004-02-19 |
Time |
15:36 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2004-02-19 |
Time |
15:36 |
Sent To |
|
|
| Notes |
| 2004-02-19 00:00:00 | ATTACHED TO PLANS SUBMITTED ON 1/29/04 | | | (BLDG) |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2004-02-05 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-02-05 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-02-05 |
Time |
10:43 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2004-01-29 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-02-04 |
Time |
11:05 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-01-29 |
Time |
16:26 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-02-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-02-18 |
Time |
14:07 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2003-02-18 |
Time |
14:06 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
N |
Date |
2004-05-27 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2004-05-27 |
Time |
07:14 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2004-05-27 |
Time |
07:11 |
Sent To |
B |
|
| Notes |
| 2004-05-27 00:00:00 | MECHANICAL PERMIT REQUIRED.PLEASE | | | PROVIDE PLANS & EQUIPMENT SCHEDULE WITH | | | MECHANICAL PERMIT APPLICATION. | | | | | | NO MECHANICAL REVISION SUBMITTED. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2004-04-01 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-05-26 |
Time |
12:10 |
Rev Time |
0.20 |
| Received By |
pkrauss |
Date |
2004-04-01 |
Time |
10:30 |
Sent To |
B |
|
| Notes |
| 2004-04-01 00:00:00 | FORM 600C SUBMITTED / NO PLANS FOR | | | REVIEW. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2004-02-12 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-02-09 |
Time |
17:17 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2004-02-12 |
Time |
07:32 |
Sent To |
B |
|
| Notes |
| 2004-02-12 00:00:00 | DENIED: | | | 1.FORM 600C #11 INDICATES COOLING | | | SYSTEM TO BE CENTRAL (FUTURE).PER | | | FBC(M) TABLE 403.3, 502.1 & FBC CHAPTER | | | 13 101.5.7, GARAGE AREA SHALL BE | | | MECHANICALLY VENTILATED AND SHALL NOT | | | HAVE A/C FOR "COMFORT" COOLING. | | | | | | 2.PLEASE INDICATE WHAT TYPE OF WORK | | | WILL BE DONE IN THE WORKSHOP. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2004-08-14 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2004-08-14 |
Time |
15:15 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2004-08-14 |
Time |
15:15 |
Sent To |
|
|
| Notes |
| 2004-08-14 00:00:00 | RESTAMP OF SET LOST/STOLEN FROM OWNER/ | | | BUILDER |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
N |
Date |
2004-05-26 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2004-08-06 |
Time |
14:06 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-05-26 |
Time |
12:10 |
Sent To |
M |
|
| Notes |
| 2004-05-26 00:00:00 | NO CHANGES TO PLUMBING PLANS |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2004-04-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-05-13 |
Time |
09:08 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2004-04-16 |
Time |
10:12 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2004-03-20 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-04-07 |
Time |
11:12 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-03-20 |
Time |
09:31 |
Sent To |
|
|
| Notes |
| 2004-03-20 00:00:00 | DENIED | | | REFERENCE: FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | FROM PREVIOUS REVIEW: | | | A PROFESSIONAL ENGINEER SHALL SIGN HIS | | | NAME AND AFFIX HIS SEAL TO ALL PLANS, | | | SPECIFICATIONS, REPORTS AND FINAL BID | | | DOCUMENTS PROVIDED TO THE OWNER OR THE | | | OWNER'S REPRESENTATIVE, OR OTHER DOCU- | | | MENTS PREPARED OR ISSUED BY SAID REGIS- | | | TRANT AND BEING FILED FOR PUBLIC RECORD. | | | THE DATE THAT THE SIGNATURE AND SEAL IS | | | AFFIXED AS PROVIDED HEREIN SHALL BE EN- | | | TERED ON SAID PLANS, SPECIFICATIONS, RE- | | | PORTS, OR OTHER DOCUMENTS IMMEDIATELY | | | UNDER THE SIGNATURE OF THE PROFESSIONAL | | | ENGINEER, FAC 61G15-23.002(1) | | | FS 471.025 | | | EACH SHEET OF PLANS AND PRINTS WHICH | | | MUST BE SEALED UNDER THE PROVISIONS OF | | | CHAPTER 471 SHALL BE SEALED, SIGNED AND | | | DATED BY THE PROFESSIONAL ENGINEER IN | | | RESPONSIBLE CHARGE. FAC 61G15-23.002(2) | | | FS 471.025 | | | ENGINEERS SHALL LEGIBLY INDICATE THEIR | | | NAME, ADDRESS AND LICENSE NUMBER ON EACH | | | SHEET. IF PRACTICING THROUGH A DULY | | | AUTHORIZED ENGINEERING BUSINESS, ENGIN- | | | EERS, ENGINEERS SHALL LEGIBLY INDICATE | | | THEIR NAME AND LICENSE NUMBER, AS WELL | | | AS, THE NAME, ADDRESS AND CERTIFICATE OF | | | AUTHORIZATION NUMBER OF THE ENGINEERING | | | BUSINESS ON EACH SHEET. A TITLE BLOCK | | | WILL SATISFY THIS REQUIREMENT. FAC | | | 61G15-23.002(2) - FS 471.025 | | | | | | INITIALS ARE NOT ACCEPTABLE PER RULING | | | BY FBPE. A SIGNATURE IS REQUIRED. | | | IF THIS IS YOUR LEGAL SIGNATURE, SUBMIT | | | A COPY OF YOUR ENGINEERS LICENSE WITH | | | THE SIGNATURE SHOWN AND A COPY OF YOUR | | | DIRVERS LICENSE WITH THE SIGNATURE SHOWN | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2004-02-09 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-17 |
Time |
16:42 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2004-02-09 |
Time |
17:17 |
Sent To |
M |
|
| Notes |
| 2004-02-09 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FLORIDA ADMIN. CODE | | | FLORIDA STATUTES | | | | | | 1) SHT S-3 SANITARY RISER DIAGRAM DOES | | | NOT REFLECT THE FLOOR PLAN, NOR DOES IT | | | MEET CODE REQUIREMENTS. | | | A) LAV SHALL BE LOCATED NEAR WASH MACH- | | | INE | | | B) WASH MACHINE AND UTILITY SINK SHALL | | | NOT DRAIN THROUGH THE WET-VENTED HORIZ- | | | ONTAL DRAIN OF THE BATHROOM FIXTURES. | | | THEY SHALL CONNECT DOWNSTREAM OF THE | | | WET VENTED FIXTURES. 909.1 | | | SEE ATTACHED SHEET FOR A SANITARY RISER | | | DIAGRAM THAT REFLECTS THE FLOOR PLAN AND | | | MEETS CODE REQUIREMENTS. | | | 2) PROFESSIONAL ENGINEER SHALL SIGN HIS | | | NAME AND AFFIX HIS SEAL TO ALL PLANS, | | | SPECIFICATIONS, REPORTS AND FINAL BID | | | DOCUMENTS PROVIDED TO THE OWNER OR THE | | | OWNER'S REPRESENTATIVE, OR OTHER DOCU- | | | MENTS PREPARED OR ISSUED BY SAID REGIS- | | | TRANT AND BEING FILED FOR PUBLIC RECORD. | | | THE DATE THAT THE SIGNATURE AND SEAL IS | | | AFFIXED AS PROVIDED HEREIN SHALL BE EN- | | | TERED ON SAID PLANS, SPECIFICATIONS, RE- | | | PORTS, OR OTHER DOCUMENTS IMMEDIATELY | | | UNDER THE SIGNATURE OF THE PROFESSIONAL | | | ENGINEER, FAC 61G15-23.002(1) | | | | | | EACH SHEET OF PLANS AND PRINTS WHICH | | | MUST BE SEALED UNDER THE PROVISIONS OF | | | CHAPTER 471 SHALL BE SEALED, SIGNED AND | | | DATED BY THE PROFESSIONAL ENGINEER IN | | | RESPONSIBLE CHARGE. FAC 61G15-23.002(2) | | | | | | ENGINEERS SHALL LEGIBLY INDICATE THEIR | | | NAME, ADDRESS AND LICENSE NUMBER ON EACH | | | SHEET. IF PRACTICING THROUGH A DULY | | | AUTHORIZED ENGINEERING BUSINESS, ENGIN- | | | EERS, ENGINEERS SHALL LEGIBLY INDICATE | | | THEIR NAME AND LICENSE NUMBER, AS WELL | | | AS, THE NAME, ADDRESS AND CERTIFICATE OF | | | AUTHORIZATION NUMBER OF THE ENGINEERING | | | BUSINESS ON EACH SHEET. A TITLE BLOCK | | | WILL SATISFY THIS REQUIREMENT. FAC | | | 61G15-23.002(2) - FS 471.025 | | | | | | INITIALS ARE NOT ACCEPTABLE PER A RULING | | | BY THE FBPE. A SIGNATURE IS REQUIRED. | | | IF THIS IS YOUR LEGAL SIGNATURE, SUBMIT | | | A COPY OF YOUR ENGINEERS LICENSE WITH | | | THE SIGNATURE SHOWN AND A COPY OF YOUR | | | DRIVERS LICENSE WITH THE SIGNATURE SHOWN | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
P |
Date |
2004-12-17 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-12-17 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-12-17 |
Time |
14:54 |
Sent To |
|
|
| Notes |
| 2004-12-17 00:00:00 | APPROVING (2) 4FT WIDE CONCRETE DRIVEWAY | | | WITH NO GRAVEL. | | | GIVEN TO PHYLLIS |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2004-05-27 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2004-05-27 |
Time |
16:01 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-05-27 |
Time |
16:00 |
Sent To |
I |
|
| Notes |
| 2004-05-27 00:00:00 | OK PER ANGELLA JONES-VANN |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2004-03-05 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2004-05-27 |
Time |
09:30 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-03-05 |
Time |
09:06 |
Sent To |
I |
|
| Notes |
| 2004-03-08 00:00:00 | APPROVED BY ANGELLA JONES-VANN 659-8031 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2004-02-04 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-03-05 |
Time |
07:57 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2004-02-04 |
Time |
11:05 |
Sent To |
I |
|
| Notes |
| 2004-02-04 00:00:00 | DENIED, NEED TO PROVIDE THE ORIGINAL | | | DOCUMENTS TO COMPLETE THE ZONING | | | REVIEWED.CALLED CONTR AND INFORMED MM |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2003-03-11 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-01-29 |
Time |
16:26 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-03-11 00:00:00 | DENIED, NO SLEEPING IS ALLOWED IN | | | ACCESSORYBLDG. | | | 2ND FLOOR USE MUST BE IDENTIFIED, NOT | | | JUST A BONUS ROOM | | | YOUR ZONING IS SF14 WHICH ALLOWS GARAGE | | | APTS, THE MAXIMUM SQUARE FOOTAGE IS | | | ONLY 750 SQ FT, YOUR GARAGE IS TOO BIG |
|
|