| Plan Review Stops For Permit 03021082 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2003-07-09 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-07-09 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-07-09 |
Time |
11:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2003-05-13 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-05-13 |
Time |
13:02 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-05-13 |
Time |
12:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-03-01 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-03-01 |
Time |
09:58 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-03-01 |
Time |
09:04 |
Sent To |
|
|
| Notes |
| 2003-03-01 00:00:00 | THE EXIT ACCESS CORRIDOR SHOWN AS "HALL" | | | ON THE PLANS IS REQUIRED TO BE ONE HOUR | | | FIRE RATED IN ACCORDANCE WITH FBC | | | 704.2.4.PLEASE REVISE AS NECESSARY. | | | | | | PROVIDE A SPECIFIC FRAMING AND FASTENING | | | DETAIL FOR THE SUSPENDED LOBBY SOFFIT | | | SHOWN ON SHEET A1.3.SEE FBC 104.2. | | | | | | SHOW THE WIND PRESSURE FOR THE NEW | | | EXTERIOR WINDOWS AND STOREFRONT SYSTEM. | | | SEE FBC 1606.1.7 | | | | | | SOME OF THE DOORS SWINGING INTO THE | | | CORRIDOR IE; ROOM 140A AND 134, DO NOT | | | COMPLLY WITH FBC 1012.1.4. | | | | | | SHOW SAFETY GLASS FOR THE INTERIOR | | | GLAZING ADJACENT TO THE DOORS AS | | | PROVIDED FOR IN FBC 2405.2.1 #3. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2003-10-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-10-20 |
Time |
08:57 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-10-20 |
Time |
08:04 |
Sent To |
|
|
| Notes |
| 2003-10-20 00:00:00 | ************ UNSAT ***************** | | | | | | 1)NOTE: PLEASE SEE FAC 61G15-23.002, | | | PLEASE SEE MISSING CA #. | | | PLEASE ALSO SEE THAT ONE SET OF PLANS | | | ARE NOT SEALED AND DATED. THEY APPEAR | | | TO BE SIGNED ONLY. | | | FS 471.025 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW.IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2003-08-04 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-15 |
Time |
14:07 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2003-08-04 |
Time |
11:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2003-07-03 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-07-30 |
Time |
11:36 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-07-03 |
Time |
06:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2003-05-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-05-12 |
Time |
13:36 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2003-05-12 |
Time |
12:40 |
Sent To |
|
|
| Notes |
| 2003-05-12 00:00:00 | *********** PROVSIO/NOTE*********** | | | | | | PLEASE SEE NOTE FROM FIRST REVIEW. | | | PLEASE SHOW LOAD CALCS AND SHOW CONT | | | @ 125% | | | | | | PLEASE REVISE LOAD CALCS BEFORE ROUGH. | | | | | | IF THERE ARE ANY QUESTION, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-03-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-03-04 |
Time |
16:37 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2003-03-04 |
Time |
16:34 |
Sent To |
|
|
| Notes |
| 2003-03-04 00:00:00 | *************** UNSAT **************** | | | | | | | | | 1)NOTE: PLAN E-1 SHOWS SECONDARY METHOD | | | OF FEEDING MDP. PLEASE SHOW ON RISER | | | THIS METHOD AS OPT. | | | | | | 2)NOTE: PLEASE SUBMIT AIC RATING FOR | | | NEW 800A MAIN DISC. 110-9 | | | | | | 3)NOTE: PLEASE SHOW LOAD CALCUALTIONS | | | AND SHOW ALL CONTINUOUS LOADS AT 125% | | | INCLUDING LIGHTING LOADS. 215-3/230-42 | | | ETC. | | | | | | | | | 4)NOTE: PLEASE SHOW FEEDER AND CONDUIT | | | SIZE FROM MAIN TO MDP. | | | | | | PLEASE ALSO SEE FIRE REVIEW COMMENTS | | | THAT WILL AFFECT ELECTRICAL PLANS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2003-07-09 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-07-09 |
Time |
11:52 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-07-09 |
Time |
11:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2003-06-05 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-06-05 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-06-05 |
Time |
15:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2003-02-26 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-02-26 |
Time |
13:40 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-02-26 |
Time |
13:39 |
Sent To |
|
|
| Notes |
| 2003-02-26 00:00:00 | 1) DOORS (140A & 140C) MUST COMPLY WITH | | | CHAPTER 7.2.1.4 OF NFPA 101 LIFE SAFETY | | | CODE 2000 EDITION. | | | | | | 2) BOARDROOM OCCUPANT LOAD MUST COMPLY | | | WITH CHAPTER 7.3.1.2 OF NFPA 101 LIFE | | | SAFETY CODE 2000 EDITION. | | | | | | 3) SEPARATE PLAN AND PERMIT ARE REQUIRED | | | FOR FIRE ALARM SYSTEM. | | | | | | 4) ADDITIONAL HORN/STROBE MAYBE NEEDED | | | IN HALL 150. | | | | | | NATE MCCRAY, CAPTAIN | | | 659-8096, EXT 8497 | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-15 |
Time |
14:07 |
Sent To |
|
|
| Notes |
| 2003-10-15 00:00:00 | TO DP DESK/REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2003-10-15 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-15 |
Time |
09:32 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-15 |
Time |
09:32 |
Sent To |
M |
|
| Notes |
| 2003-10-15 00:00:00 | TO HAROLD MOSER DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2003-07-30 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-07-30 |
Time |
11:36 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2003-07-30 |
Time |
11:36 |
Sent To |
E |
|
| Notes |
| 2003-07-30 00:00:00 | TO DP DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-07-09 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-07-09 |
Time |
14:32 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-07-09 |
Time |
14:32 |
Sent To |
Z |
|
| Notes |
| 2003-07-09 00:00:00 | REMOVED FROM BOARD, GAVE TO ZONING. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-06-18 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-18 |
Time |
16:53 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-06-18 |
Time |
16:53 |
Sent To |
|
|
| Notes |
| 2003-06-18 00:00:00 | COMM BOARD #46 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-05-07 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-07 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-07 |
Time |
13:38 |
Sent To |
|
|
| Notes |
| 2003-05-07 00:00:00 | COMM BOARD #25 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-02-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-02-26 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2003-02-26 |
Time |
14:20 |
Sent To |
|
|
| Notes |
| 2003-02-26 00:00:00 | TO #15 ON COMM BOARD. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2003-10-29 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2003-10-29 |
Time |
17:17 |
Rev Time |
0.75 |
| Received By |
hmoser |
Date |
2003-10-29 |
Time |
17:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2003-10-22 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2003-10-22 |
Time |
16:41 |
Rev Time |
0.50 |
| Received By |
hmoser |
Date |
2003-10-22 |
Time |
16:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2003-07-07 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-15 |
Time |
09:32 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2003-07-07 |
Time |
06:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2003-05-13 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-05-13 |
Time |
14:56 |
Rev Time |
0.50 |
| Received By |
pkrauss |
Date |
2003-05-13 |
Time |
14:47 |
Sent To |
|
|
| Notes |
| 2003-05-13 00:00:00 | DENIED: | | | | | | REVISED PLAN INDICATES THE PENETRATION | | | BETWEEN 132A & 131 HAS A 1 HR RATING. | | | PLEASE PROVIDE FIRE DAMPER ON THE 20" X | | | 16" SUPPLY DUCT AND THE 18" X 16" RETURN | | | DUCT.ALSO SUPPLY & RETURN DUCTS AT THE | | | MENS RM (135).PLEASE NOTE AS PER | | | 2001 FBC(M) 607.1.3 #3. 1-4 EXCEPTIONS, | | | DUCTS SHALL MEET ALL REQUIREMENTS IN | | | ITEMS 1-4 UNDER ITEM 3. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2003-03-04 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-03-04 |
Time |
09:17 |
Rev Time |
1.00 |
| Received By |
pkrauss |
Date |
2003-03-03 |
Time |
15:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2003-07-02 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-07-02 |
Time |
12:29 |
Rev Time |
0.75 |
| Received By |
kstevens |
Date |
2003-07-02 |
Time |
12:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2003-05-29 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-05-29 |
Time |
18:24 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2003-05-29 |
Time |
18:24 |
Sent To |
|
|
| Notes |
| 2003-05-29 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 11 | | | | | | 1) SHT A1.0 UNABLE TO LOCATE SERVICE | | | SINK INDICATED IN CODE ANALYSIS AND RE- | | | VIEW "E". PLEASE INDICATE LOCATION. | | | SERVICE SINK USED TO MOP FLOORS AND | | | GENERAL CLEAN-UP. | | | 2) SHT A1.0 IF URNALS ARE PROVIDED THEN | | | AT LEAST ONE SHALL COMPLY WITH 11-4.18. | | | SUBMIT DETAILS THAT SHOW HEIGHT 11-4.18. | | | 2, CLEAR FLOOR SPACE 11-4.18.3, FLUSH | | | CONTROLS 11-4.18.4. | | | 3) SHT A1.0 PLEASE SUBMIT DETAILS FOR | | | SHOWER IN COMPLIANCE WITH 11-4.21 AND | | | ALL SUBSECTIONS. 11-4.21.4 GRAB BARS, | | | 11-4.21.5 CONTROLS, 11-4.21.6 SHOWER | | | UNIT, & 11-4.21.7 CURBS. | | | 4) SHT A1.0 SINKS IN ROOMS #141 & 143, | | | SHOW CLEAR FLOOR SPACE AS REQUIRED IN | | | SECTION 11-4.24.5. | | | 5) SHTS P-1, P-2, & P-3 RELIEF VALVE | | | DISCHARGE PIPE STILL SHOWS BEING TRAPPED | | | SECTION 504.7.1 | | | 6) PER FBC ADMINISTRATIVE CODE, CHAPTER | | | 1 AND AMENDMENTS SECTION 104.2.1TWO OR | | | MORE COPIES OF SPECIFICATIONS AND OF | | | DRAWINGS DRAWN TO SCALE WITH SUFFICIEDN | | | CLAIRTY AND DETAIL TO INDICATE THE NAT- | | | URE AND CHARACTER OF THE WORK SHALL | | | ACCOMPANY THE APPLICATION FOR PERMIT. | | | SUCH INFORMATION SHALL BE SPECIFIC, AND | | | THE TECHNICAL CODES SHALL NOT BE CITED | | | AS A WHOLE OR IN PART, NOR SHALL THE | | | TERM "LEGAL" OR ITS EQUIVALENT BE USED | | | AS A SUBSTITUTE FOR SPECIFIC INFORMATION | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 | | | (561) 805-6721 | | | FAX (561) 653-2692 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-03-11 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-03-11 |
Time |
11:02 |
Rev Time |
1.50 |
| Received By |
kstevens |
Date |
2003-03-11 |
Time |
11:02 |
Sent To |
|
|
| Notes |
| 2003-03-11 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 11 | | | | | | 1) SHT A-1.0 UNABLE TO FIND DRINKING | | | FOUNTAINS AND SERVICE SINK REFERED TO IN | | | CODE REVIEW AND ANALYSIS"E". | | | 2) SHT A-1.0 IF TOILET ROOM ARE PROVIDED | | | THEN EACH PUBLIC AND COMMON USE TOILET | | | ROOM SHALL COMPLY WITH 11-4.22. IF BATH- | | | ING ARE PROVIDED, THEN EACH PUBLIC AND | | | COMMON USE BATHROOM SHALL COMPLY WITH | | | 11-4.23 - PLEASE SHOW DETAILS FOR EACH | | | TOILET ROOM AND BATHROOM PER THESE SECT- | | | IONS AND ALL SUBSECTIONS. | | | 3) SHT A-1.0 IF TOILET STALLS ARE PRO- | | | VIDED, THEN AT LEAST ON SHALL BE A | | | STANDARD TOILET STALL COMPLYING WITH | | | 11-4.17. SEC 11-4.22.4 | | | 4) SHT A-1.0 IF URNALS ARE PROVIDED THEN | | | AT LEAST ONE SHALL COMPLY WITH 11-4.18 | | | AND ALL SUBSECTIONS. | | | 5) SHT A-1.01 PLEASE SUBMIT DETAILS FOR | | | SHOWER IN COMPLIANCE WITH 11-4.21 AND | | | ALL SUBSECTIONS. | | | 6) SHT A-1.0 ALL DOORS SHALL NOT SWING | | | INTO THE CLEAR FLOOR SPACE OF ANY FIX- | | | TURE. ALSO 5' TURNING CIRCLE SHALL BE | | | UNOBSTRUCTED. | | | 7) SHT A-1.0 SINKS IN ROOMS #141 & 143 | | | SHALL COMPLY WITH 11-4.24 AND ALL SUB- | | | SECTIONS. PLEASE PROVIDE DETAILS. | | | 8) SHT P-1 RELIEF VENTS REQUIRED AS | | | CONDENSATE LINES EXIT BLDG. - CONDENSATE | | | SHALL DRAIN OUTSIDE BLDG SEPARATE FROM | | | STORM. (SEE ROOM #134) PLEASE CLAIRFY. | | | 9) SHT P-1 KEYNOTE #6. MANUF INFORMATION | | | REQUIRED. | | | 10) SHT P-2 WATER RISER DIAGRAM, WATER | | | HAMMER ARRESTORS REQUIRED AT ICE MAKERS | | | (REFRIDGERATORS) SEC 406.9 | | | 11) SHTS P-1, P-2, & P-3 RELIEF VALVE | | | (P/T) FROM WATER HEATER SHALL NOT BE | | | TRAPPED. SEC 504.7.1 | | | 12) SEPARATE PERMIT REQD FOR IRRIGATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-07-14 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-07-09 |
Time |
14:32 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-07-14 |
Time |
15:56 |
Sent To |
|
|
| Notes |
| 2003-07-14 00:00:00 | SGRAHAM PASSED |
|
|