Plan Review Details - Permit 03020454
Plan Review Stops For Permit 03020454
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-03-21 Cont ID  
Sent By shernand Date 2003-07-18 Time 16:34 Rev Time 3.00
Received By rmcdouga Date 2003-03-21 Time 11:36 Sent To  
Notes
2003-03-21 00:00:00PROVISO
  
 1) SUBMIT A SOIL BORING REPORT PRIOR TO
 POURING FOUNDATION.
  
 2) PROVIDE A PRODUCT APPROVAL FOR THE
 FRENCH DOOR, FIXED GLASS EYEBROW WINDOWS
 AND THE FINAL MIAMI-DADE NOA FOR THE
 STRUCTURAL MULLIONS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-03-04 Cont ID  
Sent By sthyng Date 2003-03-19 Time 09:03 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
2003-03-04 00:00:00BUILDING DENIED
  
 1) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 2) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 3) SUBMIT A SOIL BORING TEST REPORT AS
 REQUIRED BY FBC 1804.1.1.
  
 4) THE KEY PLAN AND INSTALLATION
 SCHEDULE THAT WAS SUBMITTED FOR THE
 STORM PANELS IS NOT FOR THIS MODEL.
 SUBMIT THE CORRECT ONES.
  
 5) SUBMIT THE MANUFACTURER'S SPECS. AND
 UL LISTING INFORMATION FOR THE ONE HOUR
 FIRE RATED GLASS BLOCK ASSEMBLY.
  
 6) PROVIDE PRODUCT APPROVALS FOR A
 SINGLE FRENCH DOOR.
  
 7) THE PRODUCT APPROVALS FOR THE SINGLE
 HUNG WINDWS IS MISSING ONE PAGE OF THE
 DRAWINGS.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-11-25 Cont ID  
Sent By btrobaug Date 2003-11-25 Time 15:53 Rev Time 0.50
Received By btrobaug Date 2003-11-25 Time 15:44 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2003-11-04 Cont ID  
Sent By csiegber Date 2003-11-21 Time 14:30 Rev Time 0.33
Received By btrobaug Date 2003-11-04 Time 13:55 Sent To  
Notes
2003-11-04 00:00:00UNSAT
 ~~~~~
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 PLEASE NOTE THE FOLLOWING DISCREPANCIES
 ON THE PLANS,MAKE CORRECTIONS TO SAME
 AND RESUBMIT FOR REVIEW.
  
 THE 200 AMP PANEL SCHEDULE SHOWS
 CIRCUITS (3)-#12 ON 2-P0LE 20 AMP
 BREAKERS FEEDING THE POOL PANEL.THE
 RISER SHOWS # 6 WIRE ON A 20 AMP
 BREAKER FEEDING A 60 AMP PANEL.THE
 OTHER PANEL WITH THE POOL EQUIPMENT
 LISTED ON IT IS LISTED AS A 200 AMP
 PANEL. PLEASE CORRELATE
 FEEDS,SCHEDULES,PANELS AND OCP'S.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-02-24 Cont ID  
Sent By csiegber Date 2003-10-29 Time 16:04 Rev Time 0.50
Received By btrobaug Date 2003-02-24 Time 18:29 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2003-11-21 Cont ID  
Sent By csiegber Date 2003-11-21 Time 14:30 Rev Time 0.00
Received By csiegber Date 2003-11-21 Time 14:30 Sent To E
Notes
2003-11-21 00:00:00TO BT DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2003-10-29 Cont ID  
Sent By csiegber Date 2003-10-29 Time 16:02 Rev Time 0.00
Received By csiegber Date 2003-10-29 Time 16:02 Sent To E
Notes
2003-10-29 00:00:00TO BT DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-07-18 Cont ID  
Sent By shernand Date 2003-07-18 Time 16:33 Rev Time 0.00
Received By shernand Date 2003-07-18 Time 16:33 Sent To B
Notes
2003-07-18 00:00:00RM DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-07-16 Cont ID  
Sent By shernand Date 2003-07-16 Time 10:50 Rev Time 0.00
Received By shernand Date 2003-07-16 Time 10:50 Sent To B
Notes
2003-07-16 00:00:00RM DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-03-19 Cont ID  
Sent By sthyng Date 2003-03-19 Time 09:03 Rev Time 0.00
Received By sthyng Date 2003-03-19 Time 09:03 Sent To B
Notes
2003-03-19 00:00:00TO RM DESK W/NOTE TO SEND TO MECH
 AFTERWARDS (MECH CHECKED OFF ON RESUB
 SHEET)

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-02-10 Cont ID  
Sent By dpalmer Date 2003-02-10 Time 10:46 Rev Time 0.00
Received By dpalmer Date 2003-02-10 Time 10:46 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-03-21 Cont ID  
Sent By rmcdouga Date 2003-03-21 Time 12:10 Rev Time 0.00
Received By rmcdouga Date 2003-03-21 Time 12:10 Sent To  
Notes
2003-03-21 00:00:00OK PER P.KRAUSS 3-20-03

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-02-22 Cont ID  
Sent By jleech Date 2003-02-19 Time 19:09 Rev Time 0.50
Received By hmoser Date 2003-02-22 Time 13:03 Sent To E
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-02-19 Cont ID  
Sent By sgraham Date 2003-02-11 Time 07:53 Rev Time 0.33
Received By jleech Date 2003-02-19 Time 19:08 Sent To M
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2003-07-21 Cont ID  
Sent By rmcdouga Date 2003-07-21 Time 11:42 Rev Time 1.00
Received By rmcdouga Date 2003-07-21 Time 11:42 Sent To  
Notes
2003-07-21 00:00:00REVISED SHEETS A3 AND A4 ARE OK 7-21-03
 RM.

Review Stop Z ZONING
Rev No 1 Status P Date 2003-02-11 Cont ID  
Sent By dpalmer Date 2003-02-10 Time 10:46 Rev Time 0.00
Received By sgraham Date   Time   Sent To P
Notes
***NONE***