| Plan Review Stops For Permit 03020418 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2003-02-18 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-02-18 |
Time |
11:10 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-02-18 |
Time |
10:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2003-02-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-02-13 |
Time |
12:51 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-02-13 |
Time |
12:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2003-02-28 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-02-28 |
Time |
09:04 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-02-28 |
Time |
09:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2003-02-07 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-02-07 |
Time |
13:41 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-02-07 |
Time |
13:41 |
Sent To |
|
|
| Notes |
| 2003-02-07 00:00:00 | 1) DOOR SCHEDULE DOES NOT INDICATE THAT | | | DOOR # 9 IS FIRE RATED. DOOR IS | | | REQUIRED TO BE FIRE RATED. | | | | | | 2) PLEASE INDICATE INTERIOR FINISH | | | CLASSIFICATION FOR WALLS AND CEILINGS. | | | | | | 3) AN EXIT SIGN IS NOTED IN THE RETAIL | | | STORAGE AREA. PLEASE REVISE ROOM NAME | | | AS EXITING IS NOT ALLOWED THRU STORAGE | | | ROOMS,KITCHENS,ETC. | | | | | | MIKE CARSILLO,ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-02-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-02-27 |
Time |
17:38 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2003-02-27 |
Time |
17:38 |
Sent To |
|
|
| Notes |
| 2003-02-27 00:00:00 | TO COMM BOARD #51 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-02-06 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-02-06 |
Time |
12:13 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2003-02-06 |
Time |
12:12 |
Sent To |
|
|
| Notes |
| 2003-02-06 00:00:00 | COM BOARD #28./WRT. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2003-03-05 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-03-05 |
Time |
15:44 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2003-03-05 |
Time |
15:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2003-02-13 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-02-13 |
Time |
13:32 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2003-02-13 |
Time |
13:25 |
Sent To |
|
|
| Notes |
| 2003-02-13 00:00:00 | DENIED: | | | | | | PROVIDE OUTSIDE AIR CALCULATIONS AS PER | | | 2001 FBC(M) TABLE 403.3 OR ASHRAE 62-89. | | | INDICATE SIZE, DUCT MATERIAL, AND LAYOUT | | | OF OUTSIDE AIR DUCT. (NEW OR EXISTING) | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2003-03-20 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-03-20 |
Time |
12:24 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-03-20 |
Time |
12:24 |
Sent To |
|
|
| Notes |
| 2003-03-20 00:00:00 | PASSED-PROVISO | | | | | | FLOOR SINKS REQUIRED FOR ALL INDIRECT | | | WASTE. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-02-08 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-02-08 |
Time |
06:43 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2003-02-08 |
Time |
06:43 |
Sent To |
|
|
| Notes |
| 2003-02-08 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 11 | | | | | | 1) DEMO NOTES: ALL CAPPED PLUMBING PIPES | | | SHALL BE INSPECTED PRIOR TO COVERING. | | | 2) TABLE 403.1 DRINKING FOUNTAIN REQUIR- | | | ED. ALSO SEE 410.1 (ARI-1010) | | | 3) SHT MP-2 ALL INDIRECT WASTE SHALL | | | DRAIN TO A FLOOR SINK SEC 802.3 WITH | | | A TRAP PRIMER. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|