Plan Review Details - Permit 03020313
Plan Review Stops For Permit 03020313
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2003-02-24 Cont ID  
Sent By dpalmer Date 2003-02-20 Time 18:28 Rev Time 2.00
Received By jgomez Date 2003-02-24 Time 17:00 Sent To  
Notes
2003-02-24 00:00:00BUILDING REVIEW APPROVED WITH PROVISO:
 1-PROVIDE COMPLETE INFORMATION FOR STORM
 SHUTTERS UNDER A SEPARATE PERMIT.
 2-FLOOD ZONE A8. NEED TO PROVIDE THE
 ELEVATION CERTIFICATE.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-08-19 Cont ID  
Sent By dpalmer Date 2003-08-19 Time 12:29 Rev Time 0.25
Received By dpalmer Date 2003-08-19 Time 12:29 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2003-08-11 Cont ID  
Sent By dbaxter Date 2003-08-14 Time 09:02 Rev Time 0.25
Received By dpalmer Date 2003-08-11 Time 18:25 Sent To  
Notes
2003-08-11 00:00:00************* UNSAT ****************
  
 1)NOTE: PLEASE INCLUDE ADDRESS ON TITLE
 BLOCK AS REQ'D UNDER FAC 61G1-16.004
  
 2)NOTE: PLEASE ALSO HAVE PLANS WITH
 ORIGINAL SIGNATURES PER FS 481.221
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-02-20 Cont ID  
Sent By alange Date 2003-08-06 Time 10:33 Rev Time 0.25
Received By dpalmer Date 2003-02-20 Time 18:28 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2003-08-14 Cont ID  
Sent By dbaxter Date 2003-08-14 Time 09:02 Rev Time 0.00
Received By dbaxter Date 2003-08-14 Time 09:02 Sent To E
Notes
2003-08-14 00:00:00TO DPALMER DESK.

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-08-06 Cont ID  
Sent By alange Date 2003-08-06 Time 10:33 Rev Time 0.00
Received By alange Date 2003-08-06 Time 10:33 Sent To E
Notes
2003-08-06 00:00:00TO DP DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-08-01 Cont ID  
Sent By alange Date 2003-08-01 Time 15:04 Rev Time 0.00
Received By alange Date 2003-08-01 Time 15:04 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-03-04 Cont ID  
Sent By dpalmer Date 2003-03-04 Time 08:51 Rev Time 0.00
Received By dpalmer Date 2003-03-04 Time 08:51 Sent To M
Notes
2003-03-04 00:00:00TO HM`S DESK.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-02-06 Cont ID  
Sent By dpalmer Date 2003-02-06 Time 12:43 Rev Time 0.00
Received By dpalmer Date 2003-02-06 Time 12:43 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2003-08-14 Cont ID  
Sent By pkrauss Date 2003-08-14 Time 13:41 Rev Time 0.25
Received By pkrauss Date 2003-08-14 Time 13:41 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-03-10 Cont ID  
Sent By alange Date 2003-08-01 Time 15:04 Rev Time 0.25
Received By hmoser Date 2003-03-10 Time 18:12 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2003-02-19 Cont ID  
Sent By dpalmer Date 2003-03-04 Time 08:51 Rev Time 0.25
Received By hmoser Date 2003-02-19 Time 19:40 Sent To E
Notes
2003-02-19 00:00:00PLAN DENIED
 1) ENERGY PERFORMANCE LEVEL DISPLAY CARD
 AND ENERGY CALCULATIONS DO NOT MATCH.
 2) EQUIPMENT SELESTION ON MANUAL (J) NOT
 COMPLETE.
 3) COOLING & HEATING BTU.ON MANUAL (J)
 DO NOTMATCH PLANS.
 PLAN REVIEW BY HAROLD MOSER
 (561)689-8096 EXT.8390

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-02-10 Cont ID  
Sent By sgraham Date 2003-02-06 Time 14:37 Rev Time 0.25
Received By kstevens Date 2003-02-10 Time 12:53 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-02-06 Cont ID  
Sent By dpalmer Date 2003-02-06 Time 12:43 Rev Time 0.00
Received By sgraham Date   Time   Sent To P
Notes
***NONE***