| Plan Review Stops For Permit 03020062 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2003-06-02 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-06-02 |
Time |
15:54 |
Rev Time |
1.50 |
| Received By |
sthyng |
Date |
2003-06-02 |
Time |
15:54 |
Sent To |
E |
|
| Notes |
| 2003-06-02 00:00:00 | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | I HAVE REVIEWED THE DOCUMENTATION | | | PROVIDED FOR THE TWO DOORS. | | | | | | IF A DOOR HAS GLASS, IT NEEDS TO BE | | | PROTECTED. | | | | | | THE JELD WEN DOOR PACKAGE HAS A PRODUCT | | | APPROVAL IN IT.IF YOU WISH TO USE | | | THIS DOOR, SUBMIT TWO LEGIBLE COPIES. | | | | | | THE DESIGNER CLASSICS DOOR WOULD | | | REQUIRE A SITE SPECIFIC PRODUCT | | | APPROVAL.A FORM IS ATTACHED.IT NEEDS | | | TO BE SIGNED AND SEALED IN BOTH BOXES | | | AT THE BOTTOM, TWO COPIES. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2003-05-21 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-29 |
Time |
08:08 |
Rev Time |
1.00 |
| Received By |
sthyng |
Date |
2003-05-21 |
Time |
11:55 |
Sent To |
|
|
| Notes |
| 2003-05-21 00:00:00 | *****CORRECTIONS****** | | | | | | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)GIVE DIMENSION OF THE WINDOW IN | | | BEDROOM #1.REQUIRED TO HAVE EMERGENCY | | | EGRESS FBC 1005.4. | | | | | | 2.)PROVIDE A FRAMING DETAIL FOR THE | | | NEW FRENCH DOORS.IF THE FRENCH DOORS | | | ARE EXTERIOR, PROVIDE PRODUCT APPROVALS. | | | | | | 3.)STUCCO ON METAL PLASTER BASE | | | REQUIRED TO BE 7/8", FBC 2504.2, | | | ASTM C 926. | | | | | | 4.)GIVE SPACING FOR BOTTOM PLATE | | | ATTACHMENT. | | | | | | 5.)SPECIFY INSULATION IN WALLS, NOT | | | "AS REQUIRED". |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2003-04-02 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-05-21 |
Time |
07:52 |
Rev Time |
3.50 |
| Received By |
sthyng |
Date |
2003-04-01 |
Time |
19:54 |
Sent To |
P |
|
| Notes |
| 2003-04-01 00:00:00 | PROVISOS - | | | | | | 1.)SUBMIT PRODUCT APPROVALS FOR | | | EITHER IMPACT WINDOWS ON 2ND STORY | | | OR HURRICANE PROTECTION THAT CAN BE | | | OPENED FROM THE INSIDE. | | | | | | 2.)SUBMIT PRODUCT APPROVALS FOR | | | MULLIONS. | | | | | | 3.)SUBMIT SOIL REPORT FOR NEW SLAB | | | SHOWING BEARING VALUE. | | | | | | 4.)DOOR 004 TO HAVE 29" CLEAR | | | OPENING PER FBC 11-11 (1). |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2003-03-27 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-04-01 |
Time |
17:40 |
Rev Time |
5.00 |
| Received By |
sthyng |
Date |
2003-03-27 |
Time |
13:27 |
Sent To |
|
|
| Notes |
| 2003-03-27 00:00:00 | **********CORRECTIONS************ | | | | | | 1.)IMPACT FEES ARE FOR 642 SF, | | | ADDITION IS 1284 SF.PLEASE REVISE | | | WITH THE COUNTY. | | | | | | 2.)SITE DATA (SHEET 1.1) STATES A | | | BUILDING HEIGHT OF 1739 SF.PLEASE | | | CORRECT. | | | | | | 3.)PROVIDE OPENING SIZE FROM THE | | | MANUFACTURER FOR WINDOWS #8 AND #9 ON | | | THE WINDOW SCHEDULE. | | | THEY ARE INDICATED AS EGRESS WINDOWS | | | BUT DO NOT APPEAR TO MEET THE OPENING | | | MEET THE OPENING REQUIREMENTS AS PER | | | BC 1005.4.IF A DIFFERENT TYPE OF | | | WINDOW IS TO BE USED OTHER THAN A | | | SINGLE HUNG, SUBMIT A PRODUCT APPROVAL | | | FOR THAT WINDOW. | | | | | | 4.)THE ARCHITECT ADDRESSED COMMENT | | | #3 IN REGARDS TO 2ND STORY WINDOWS TO | | | BE EITHER IMPACT OR SHUTTERS REMOVEABLE | | | FROM THE INSIDE.PLEASE SUBMIT A | | | PRODUCT APPROVAL FOR EITHER THE IMPACT | | | GLASS WINDOW OR A STORM SHUTTER THAT | | | IS OPERABLE FROM THE INSIDE. | | | | | | 5.)FL. BLD CODE 1606.1.7 THE FOLLOWING | | | INFORMATION RELATED TO WIND SHALL BE | | | SHOWN ON THE CONSTRUCTION DRAWINGS, | | | 1)- BASIC WIND SPEED, MPH | | | 2)- WIND IMPORTANCE FACTOR, & BUILDING | | | CATEGORY | | | 3)- WIND EXPOSURE | | | 4)- INTERNAL PRESSURE COEFFICIENT, | | | 5)- COMPONENTS & CLADDING, THE DESIGN | | | WIND PRESSURES IN TERMS OF PSF. | | | | | | 6.)SEPARATE PERMITS REQUIRED FOR | | | FENCE AND GAS. | | | | | | 7.)ADDITIONAL FEES REQUIRED; CAN PAY | | | WHEN PERMIT IS ISSUED. | | | | | | 8.)SUBMIT SOIL REPORT FOR NEW SLAB | | | SHOWING BEARING VALUE (CAN SUBMIT LATER) | | | | | | 9.)PROVIDE PRODUCT APPROVALS FOR | | | THE MULLIONS. | | | | | | LOOK FOR COMMENTS BY THE OTHER PLAN | | | REVIEW DISCIPLINES THAT MAY BE WRITTEN | | | ON THE APPLICATION, PLANS, OR ATTACHED | | | SEPARATELY. WHEN RESUBMITTING PLANS | | | PLEASE CLEARLY INDICATE THE REVISION AND | | | REMOVE AND REPLACE ANY PAGES AS NECESS- | | | ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH | | | THE PLANS WHEN RESUBMITTING PLANS. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN | | | BE FOUND, WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | | 561-659-8096, EXTENSION 8340 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-03-06 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-02-28 |
Time |
09:44 |
Rev Time |
2.50 |
| Received By |
lsmith |
Date |
2003-03-06 |
Time |
08:18 |
Sent To |
|
|
| Notes |
| 2003-03-06 00:00:00 | ****************FAILED**************** | | | ALL CONSTRUCTION MUSTCOMPLY WITH THE | | | FBC 2001 & MEET 140 MPH WIND ZONE | | | | | | 1. SUBMIT PRODUCT APPROVALS FOR THE | | | FOLLOWING: | | | A. WINDOWS | | | B. WINDOW MULLIONS | | | B. DOORS | | | C. HURRICANE PANELS* | | | D. ROOF MATERIALS | | | 2. SUBMIT 2ND COPY OF ENERGY CALCS. | | | 3. IF 2ND FLOOR WINDOWS ARE NOT IMPACT | | | SHUTTERS MUST BE CAPABLE OF BEING | | | INSTALLED FROM INTERIOR. | | | 4. SEPARATE PERMITS REQUIRED FOR FENCE | | | AND GAS. | | | 5. SUBMIT SOIL REPORT FOR NEW SLAB | | | SHOWING BEARING VALUE. | | | 6. PLANS MUST BE TAKEN TO PBC BUILDING | | | DEPARTMENT AND STAMPED AND IMPACT | | | FEES PAID BEFORE PERMIT CAN BE ISSUED | | | 7. ADDITIONAL FEES REQUIRED; CAN PAY | | | WHEN PERMIT IS ISSUED. | | | 8. PROVIDE A WINDOW SCHEDULE PRIOR TO | | | INSTALLATION.INDICATE ALL EXISTING | | | BEDROOM WINDOWS ON THE PLAN SHOWING | | | SIZES AS PER FBC 1005.4. | | | 9. DRAFTSTOPPING IS REQUIRED BETWEEN | | | FLOORS AS PER FBC 2305.2.2. | | | 10.HUGHES STRAPS SPECIFIED ARE NOT | | | AVAILABLE.PLEASE REVISE. | | | | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | PHONE: 805-6713 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2003-06-02 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-06-02 |
Time |
17:06 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2003-06-02 |
Time |
17:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2003-05-21 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-06-02 |
Time |
16:09 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2003-05-21 |
Time |
07:39 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2003-04-01 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-19 |
Time |
14:25 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2003-04-01 |
Time |
16:38 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2003-03-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-03-17 |
Time |
07:49 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2003-03-17 |
Time |
07:49 |
Sent To |
P |
|
| Notes |
| 2003-03-17 00:00:00 | **************** UNSAT **************** | | | | | | PLEASE SEE PLANS, A COMPETELY NEW | | | RISER DIAGRAM IS SUBMITTED. PLEASE | | | SEE COMMENTS. | | | | | | PLEASE SEE SOME NOTES FROM FIRST REVIEW | | | WERE NOT ADDRESSED. | | | | | | 1)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | NEW MAIN DISC SHOWN. PLEASE ALSO NOTE | | | AIC RATING FOR PANEL WAS ON ORIG PLANS | | | AND NOT SHOWN ON NEW? 110-9/215-5 | | | | | | 2)NOTE: PLEASE SEE PANEL SCHEDULE, THERE | | | ARE STILL MANY ITEMS THAT DO NOT | | | CORRELATE. PLEASE SEE OCP AND AWG. | | | | | | 3)NOTE: PLEASE LIST THE REQ`D ARC FAULT | | | PROTECTED CIRCUITS ON PANEL SCHEDULE FOR | | | BEDRROMS. 210-12, PLEASE VERIFY ARD | | | FAULT NOW SHOWN FOR LIVING ROOM? | | | | | | 4)NOTE: PLEASE SEE LOAD CALCULATIONS, | | | PLEASE DO CALCS PER NEC 220. | | | | | | 5)NOTE: PLEASE SEE ORIG NOTES, WE ARE | | | UNDER 99 NEC. | | | | | | 6)NOTE: PLEASE SEE 2-POLE BRKR SHOWN FOR | | | SM APPL CIRCUIT? | | | | | | 7)NOTE: RISER NOW SHOWS A NEW MAIN DISC, | | | PLEASE SEE PANEL STILL SHOWS A 200A MAIN | | | BEING INSTALLED. PLEASE NOTE, IF A MAIN | | | IS USED, A MCB IS NOT REQ`D AND MAY 'USE | | | MLO? | | | | | | | | | PLEASE SEE ATTACHED LETTER PER FS/ FAC | | | 553-80(2) (B). | | | | | | PLEASE SUBMIT ALL THE ABOVE INFORMATION | | | FOR REVIEW. IF THERE ARE NAY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-02-20 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-03-14 |
Time |
14:13 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2003-02-20 |
Time |
13:10 |
Sent To |
P |
|
| Notes |
| 2003-02-20 00:00:00 | *************** UNSAT **************** | | | | | | 1)NOTE: PLEASE CORRELATE ELECTRICAL | | | RISER DIAGRAM AND PANEL DETAIL. | | | THERE ARE MANY ITEMS THAT DO NOT MATCH, | | | CONDUCTORS, CONDUITS ETC. | | | | | | 2)NOTE:PLEASE SEE PANEL SCHEDULE, THERE | | | ARE MANY ITEMS, PLEASE SEE OCP AND AWG | | | 240-3, PLEASE SEE 20A BRKRS ON #14 AWG? | | | | | | 3)NOTE: PLEASE SEE 210-52 FOR MIN REQ`D | | | SMALL APPL CIRCUITS, PLANS SHOW NEW | | | KITCHEN AND PANEL SCHEDULE ONLY SHOWS | | | ONE EXISTING SM APPL CIRCUIT?? 210-11 | | | PLEASE ALSO SEE OTHER CIRCUTIS SHOWN | | | AS EXISTING AND SHOWN AS NEW ON PLAN. | | | | | | 4)NOTE: PLEASE LIST THE REQ`D BATH | | | CIRCUITS AS #12 AND 20, 210-11-C-3 | | | SHOWN AS #14. | | | | | | 5)NOTE: PLEASE LIST THE REQ`D ARC FAULT | | | PROTECTED CIRCUITS PER 210-12 | | | | | | 6)NOTE: PLANS/RISER SHOWS AN EQUIPMENT | | | GROUNDING CONDUCTOR BEING INSTALLED | | | BETWEEN METER AND PANEL. PLEASE SEE | | | 250-24, ONLY AFTER THE FIRST MEANS OF | | | DISC. | | | | | | 7)NOTE: PLEASE INCLUDE BLDG FOOTER | | | STEEL AS PART OF GROUNDING ELECTRODE | | | SYSTEM. 250-50. | | | | | | 8)NOTE: PLEASE SEE NOTES LISTED, REF TO | | | A 2001 NEC? | | | THE 99 NEC AND THE NEXT NEC WILL BE | | | 2002. | | | | | | 9)NOTE: SD MISSING AT THE BOTTOM OF | | | STAIR, REQ`D PER NFPA-72 8-1.4.2 | | | | | | 10)NOTE: PLEASE RE-CONFIGURE LOAD | | | CALCULATIONS TO MEET NEC ART 220. | | | PLEASE NOTE, A/C LOADS MAY NOT BE | | | DERATED @40% WITH LIGHTING LOADS. | | | | | | | | | 11)NOTE: PLEASE SEE 210-52D FOR OUTLET | | | SPACING WITHIN 3" OF SINKS IN BATHS. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2003-05-29 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-29 |
Time |
08:07 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-29 |
Time |
08:07 |
Sent To |
B |
|
| Notes |
| 2003-05-29 00:00:00 | STHYNG DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-05-19 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-19 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-19 |
Time |
14:25 |
Sent To |
E |
|
| Notes |
| 2003-05-19 00:00:00 | DP DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-03-14 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-03-14 |
Time |
14:13 |
Rev Time |
0.00 |
| Received By |
sthyng |
Date |
2003-03-14 |
Time |
14:13 |
Sent To |
E |
|
| Notes |
| 2003-03-14 00:00:00 | TO DP DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-02-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-02-20 |
Time |
08:45 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2003-02-20 |
Time |
08:45 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-02-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-02-04 |
Time |
08:47 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2003-02-04 |
Time |
08:47 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2003-03-26 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-03-26 |
Time |
13:38 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2003-03-26 |
Time |
13:16 |
Sent To |
|
|
| Notes |
| 2003-03-26 00:00:00 | MECHANICAL PERMIT 03020063 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2003-02-28 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-03-24 |
Time |
06:53 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2003-02-28 |
Time |
09:40 |
Sent To |
B |
|
| Notes |
| 2003-02-28 00:00:00 | PROVISO:MECHANICAL PERMIT 03020063 | | | | | | EXHAUST FAN REQUIRED IN SHOWER AREA AS | | | WELL AS TOILET ROOM AS PER 2001 FBC(M) | | | 402.3.1. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2003-04-02 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-04-02 |
Time |
18:14 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2003-04-02 |
Time |
13:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2003-03-24 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-04-01 |
Time |
19:55 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2003-03-24 |
Time |
06:41 |
Sent To |
M |
|
| Notes |
| 2003-03-24 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | 1) SANITARY RISER DIAGRAM DOES NOT MEET | | | CODE. (2ND NOTICE) WATER LINES SHALL NOT | | | TIE INTO SANITARY LINES. WASHER REQUIRES | | | A 2" STANDPIPE AND NEES TO BE SHOWN ON | | | THE RISER DIAGRAM. REMOVE DISHWASHER AND | | | REFERENCE TO REFRIGERATOR AND ICE MAKER | | | FROM RISER DIAGRAM. LAV NOT VENTED IN | | | MASTER BATH. | | | | | | 2) PLEASE SUBMIT COMPLETE SETS OF PLANS. | | | REMOVE ALL OLD SHEET AND INSERT NEW | | | SHEETS FOR REVIEW AND STAMPING. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-02-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-03-17 |
Time |
07:50 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-02-27 |
Time |
15:58 |
Sent To |
M |
|
| Notes |
| 2003-02-27 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | 1) SANITARY RISER DIAGRAM DOES NOT MEET | | | CODE REQUIREMENTS. WATER LINES SHALL NOT | | | TIE INTO SANITARY LINES. WASHER NEEDS A | | | 2" STANDPIPE AND REQUIRES VENTING. KIT. | | | SINK NOT VENTED. DISHWASHER SHALL TIE IN | | | TO TAILPIECE UPSTREAM OF TRAP. 3" VTR | | | SHALL TIE INTO DRAIN UPSTREAM OF W/C IN | | | 2ND FLOOR BATH. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2003-02-06 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2003-02-06 |
Time |
16:13 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2003-02-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-02-04 |
Time |
08:47 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-02-05 00:00:00 | DENIED, NEED A SITE PLAN |
|
|