| Plan Review Stops For Permit 03012458 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2003-12-12 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2003-12-12 |
Time |
16:36 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2003-12-12 |
Time |
16:36 |
Sent To |
|
|
| Notes |
| 2003-12-12 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6716 | | | E-MAIL: [email protected] | | | | | | SUBMITTAL ON 12/9/03, FOR WINDOW AND | | | DOOR PRODUCT APPROVAL. | | | | | | 1) THE DOOR SCHEDULE SPECIFIES DOOR | | | MARK #3 AS A 2'-8"X 6'-8" DOOR.THE | | | SUBMITTED SITE SPECIFIC PRODUCT APPROVAL | | | SUBMITTAL FORM SPECIFIES 2'-6"X 6'-8" | | | AND IS THEREFORE NOT APPLICABLE.ALSO, | | | THE SUBMITTED FORM DOES NOT STATE THE | | | 'JOB/SITE LOCATION', IN THE SPACE | | | ALLOCATED, BELOW THE SIGNATURE OF THE | | | DESIGNER OF RECORD (BOTTOM RIGHT CORNER) | | | | | | 2) NO PRODUCT APPROVAL HAS BEEN | | | SUBMITTED FOR THE PROPOSED DOUBLE DOOR | | | MARK #1 | | | | | | 3) CARADCO WOOD CASEMENT WINDOW PRODUCT | | | APPROVAL NOA# 01-0814.05.THE SUBMITTED | | | PRODUCT APPROVAL SHEETS ARE POOR COPIES | | | AND CANNOT BE READ.THE DESIGN LOAD | | | CAPACITY TABLES ON DRAWING SHEETS 1 AND | | | 5 OF 5 ARE ALMOST ENTIRELY ILLEGIBLE. | | | SUBMIT LEGIBLE COPIES.ALSO, NOTE THAT | | | THE PRODUCT APPROVAL SHEETS SHALL BE | | | MARKED, AS APPROPRIATE TO IDENTIFY WHICH | | | PRODUCT OPTIONS/MATERIALS/SIZES ARE TO | | | BE USED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2003-10-07 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-09 |
Time |
10:11 |
Rev Time |
0.50 |
| Received By |
sthyng |
Date |
2003-10-03 |
Time |
17:17 |
Sent To |
|
|
| Notes |
| 2003-10-03 00:00:00 | ****CORRECTIONS***** | | | | | | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | | [email protected] | | | | | | 1.)SUBMIT ALL PRODUCT APPROVALS | | | AT ONE TIME (DOORS, WINDOWS, IMPACT | | | PROTECTION).ANY ITEMS NOT INCLUDED | | | IN THE NEXT SUBMITTAL WILL REQUIRE | | | SEPARATE PERMITS FOR THOSE ITEMS. | | | | | | 2.)SUBMIT A PRODUCT APPROVAL, SITE | | | SPECIFIC PRODUCT APPROVAL (ATTACHED) OR | | | OTHER APPROVED TEST REPORT AS PER | | | FBC CHAPTER 17 FOR THE WOOD DOOR. | | | | | | 3.)THE PERSONAL SEAL, SIGNATURE AND | | | DATE OF THE ARCHITECT SHALL APPEAR ON | | | ARCHITECTURAL DOCUMENTS TO BE FILED | | | FOR PUBLIC RECORD, FAC61G1-16.003. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2003-03-05 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-01 |
Time |
09:56 |
Rev Time |
2.00 |
| Received By |
sthyng |
Date |
2003-03-05 |
Time |
10:16 |
Sent To |
|
|
| Notes |
| 2003-03-05 00:00:00 | PASSED PER LS | | | | | | PROVISO | | | 1.)SUBMIT PRODUCT APPROVALS FOR | | | DOORS, WINDOWS, MULLIONS AND HURRICANE | | | SHUTTERS. | | | | | | 2.)INSPECTION REQUIRED AFTER | | | SUBFLOORS ARE REMOVED. | | | | | | 3/5/03 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-03-04 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-03-04 |
Time |
15:27 |
Rev Time |
2.50 |
| Received By |
sthyng |
Date |
2003-02-24 |
Time |
16:04 |
Sent To |
|
|
| Notes |
| 2003-02-24 00:00:00 | **********CORRECTIONS************ | | | | | | 1.)PLEASE PROVIDE PRODUCT APPROVALS | | | FOR ALL WINDOWS, EXTERIOR DOORS, AND | | | HURRICANE SHUTTERS (2 COPIES OF EACH). | | | CLEARLY MARK ATTACHMENTS TO BE USED. | | | | | | 2.)PLEASE PROVIDE A DETAIL FOR THE | | | NEW CONCRETE LANDING AND STEPS. | | | | | | 3.)INSPECTION REQUIRED AFTER SUBFLOOR | | | ON 2ND STORY IS REMOVED. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | LEA SMITH OR SAMANTHA THYNG | | | 561-659-8096, EXTENSION 8340 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2003-03-04 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-03-04 |
Time |
15:26 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2003-03-04 |
Time |
15:26 |
Sent To |
B |
|
| Notes |
| 2003-03-04 00:00:00 | TO SAMANTHA./WRT |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-02-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-02-28 |
Time |
17:25 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2003-02-14 |
Time |
11:06 |
Sent To |
B |
|
| Notes |
| 2003-02-20 00:00:00 | UNSAT | | | ~~~~~ | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | PLEASE PROVIDE THE FOLLOWING | | | INFORMATIONMAKE NECESSARY CORRECTIONS | | | ON PLANS AND RESUBMIT FOR REVIEW. | | | | | | 1} THE RISER SHOWS # 6 GEC,A #4 IS | | | REQUIRED AND WAS SHOWN ON THE SERVICE | | | CHANGERISER ON PREVIOUS PERMIT. | | | PLEASE SHOW EXISTING RISER AS IT IS | | | INSTALLED. | | | | | | 2} CIRCUIT C-4 ON SHEET E-2 SHOWS # 14 | | | WIRE TO THE MASTER BATH,MUST COMPLY | | | WITH 210-11(C)(3),20 AMP W/# 12 WIRE. | | | | | | 3} CIRCUIT C-14 IN THE TOWER ROOM NOT | | | SHOWN ON THE PANEL SCHEDULE. | | | | | | 4} TOWER ROOM NEEDS A SMOKE DETECTOR TO | | | COMPLY WITH 8-1.4.1.6.2(3),NFPA-72. | | | | | | 5} MASTER BATH CIRCUITS LISTED AS C-7 | | | ONTHE PLAN AND BEDROOM ON PANEL | | | SCHEDULE.PLAESE CORRELATE THE SCHEDULES | | | WITH THE CIRCUIT LOCATIONS. | | | | | | 6} PLEASE LIST THE REQ`D BATH(S) | | | CIRCUIT(S). PER 210-11-C-3 | | | MUST BE 20A AND #12AWG. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/659-8096 EXT.8392 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-12-09 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-12-09 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-12-09 |
Time |
10:11 |
Sent To |
B |
|
| Notes |
| 2003-12-09 00:00:00 | TO ST DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-10-01 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-10-01 |
Time |
09:56 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-10-01 |
Time |
09:56 |
Sent To |
B |
|
| Notes |
| 2003-10-01 00:00:00 | TO ST DESK/SUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-02-28 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-02-28 |
Time |
17:25 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2003-02-28 |
Time |
17:24 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-01-31 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-01-31 |
Time |
17:41 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2003-01-31 |
Time |
17:41 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2003-02-12 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-02-11 |
Time |
08:39 |
Rev Time |
0.50 |
| Received By |
hmoser |
Date |
2003-02-12 |
Time |
18:45 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2003-02-11 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-02-11 |
Time |
08:38 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-02-11 |
Time |
08:37 |
Sent To |
M |
|
| Notes |
| 2003-02-11 00:00:00 | PASSED/PROVISO | | | | | | WATER HAMMER ARRESTORS - LOCATED NEAR | | | THE FIXTURE NOT IN CEILING - PDI-WH 201 | | | & MANUF. INSTALL. INSTRUCTIONS |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-02-07 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-01-31 |
Time |
17:47 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
B |
|
| Notes |
|
|