Plan Review Details - Permit 03012385
| Plan Review Stops For Permit 03012385 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2003-04-21 |
|
|
Cont ID |
|
| Sent By |
lhatten |
Date |
2003-04-21 |
Time |
09:39 |
Rev Time |
1.00 |
| Received By |
lhatten |
Date |
2003-04-18 |
Time |
09:38 |
Sent To |
|
|
| Notes |
| 2003-04-21 00:00:00 | REVIEWED 04/18/2003 | | | CALC. FEES & PRINT CARD 04/21/2003 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2003-04-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-04-17 |
Time |
08:25 |
Rev Time |
2.50 |
| Received By |
lhatten |
Date |
2003-03-15 |
Time |
08:14 |
Sent To |
|
|
| Notes |
| 2003-04-09 00:00:00 | REVIEW & STAMPED PLANS 03/15/2003 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2003-04-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-04-17 |
Time |
08:25 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2003-04-17 |
Time |
08:25 |
Sent To |
B |
|
| Notes |
| 2003-04-17 00:00:00 | SENT TO LOU HATTEN FOR NOTES AND STAMP-I | | | NG. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-02-13 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-15 |
Time |
15:35 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2003-02-13 |
Time |
07:29 |
Sent To |
P |
|
| Notes |
| 2003-02-13 00:00:00 | *********** UNSAT *********** | | | | | | 1)NOTE: PLEASE SHOW PANEL SCHEDULE FOR | | | NEW SUB PANEL. | | | PLEASE LIST THERE REQ`D ARC FAULT | | | CIRCUIT PER 210-12 | | | PLEASE LIST THE REQ`D 20A BATH CIRCUIT | | | PER 210-52D/210-11-C3 | | | PLEASE LIST ANY OTHER NEW ITEMS BEING | | | FED FROM NEW PANEL. PLEASE SHOW OCP/AWG. | | | | | | 2)NOTE: PLEASE SEE RISER DIAGRAM, SHOWS | | | 200A SERVICE WITH #1'S? PLEASE SEE MIN | | | REQ`MENTS FOR SEC`S. 310-15. | | | | | | 3)NOTE: PLEASE SEE CONDUCTOR SIZE | | | FEEDING NEW 80A SUB-PANEL. PLEASE SEE | | | 310-16 FOR AWG. 75 DEGREE COL. 110-14 | | | PLEASE ADJUST AWG/CONDUIT. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-04-15 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-15 |
Time |
15:35 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-04-15 |
Time |
15:34 |
Sent To |
E |
|
| Notes |
| 2003-04-15 00:00:00 | DP DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-02-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-02-12 |
Time |
16:34 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2003-02-12 |
Time |
16:34 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-01-31 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2003-02-11 |
Time |
11:53 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2003-01-31 |
Time |
16:35 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2003-02-28 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-02-27 |
Time |
11:03 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2003-02-28 |
Time |
14:35 |
Sent To |
B |
|
| Notes |
| 2003-02-28 00:00:00 | MECHANICAL PERMIT 03012479 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2003-02-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-02-13 |
Time |
07:29 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2003-02-27 |
Time |
11:03 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-02-11 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-01-31 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
I |
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |