Plan Review Details - Permit 03012385
Plan Review Stops For Permit 03012385
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-04-21 Cont ID  
Sent By lhatten Date 2003-04-21 Time 09:39 Rev Time 1.00
Received By lhatten Date 2003-04-18 Time 09:38 Sent To  
Notes
2003-04-21 00:00:00REVIEWED 04/18/2003
 CALC. FEES & PRINT CARD 04/21/2003

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2003-04-09 Cont ID  
Sent By dpalmer Date 2003-04-17 Time 08:25 Rev Time 2.50
Received By lhatten Date 2003-03-15 Time 08:14 Sent To  
Notes
2003-04-09 00:00:00REVIEW & STAMPED PLANS 03/15/2003

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-04-17 Cont ID  
Sent By dpalmer Date 2003-04-17 Time 08:25 Rev Time 1.00
Received By dpalmer Date 2003-04-17 Time 08:25 Sent To B
Notes
2003-04-17 00:00:00SENT TO LOU HATTEN FOR NOTES AND STAMP-I
 NG.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2003-02-13 Cont ID  
Sent By shernand Date 2003-04-15 Time 15:35 Rev Time 0.25
Received By dpalmer Date 2003-02-13 Time 07:29 Sent To P
Notes
2003-02-13 00:00:00*********** UNSAT ***********
  
 1)NOTE: PLEASE SHOW PANEL SCHEDULE FOR
 NEW SUB PANEL.
 PLEASE LIST THERE REQ`D ARC FAULT
 CIRCUIT PER 210-12
 PLEASE LIST THE REQ`D 20A BATH CIRCUIT
 PER 210-52D/210-11-C3
 PLEASE LIST ANY OTHER NEW ITEMS BEING
 FED FROM NEW PANEL. PLEASE SHOW OCP/AWG.
  
 2)NOTE: PLEASE SEE RISER DIAGRAM, SHOWS
 200A SERVICE WITH #1'S? PLEASE SEE MIN
 REQ`MENTS FOR SEC`S. 310-15.
  
 3)NOTE: PLEASE SEE CONDUCTOR SIZE
 FEEDING NEW 80A SUB-PANEL. PLEASE SEE
 310-16 FOR AWG. 75 DEGREE COL. 110-14
 PLEASE ADJUST AWG/CONDUIT.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-04-15 Cont ID  
Sent By shernand Date 2003-04-15 Time 15:35 Rev Time 0.00
Received By shernand Date 2003-04-15 Time 15:34 Sent To E
Notes
2003-04-15 00:00:00DP DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-02-12 Cont ID  
Sent By dpalmer Date 2003-02-12 Time 16:34 Rev Time 0.00
Received By dpalmer Date 2003-02-12 Time 16:34 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-01-31 Cont ID  
Sent By sgraham Date 2003-02-11 Time 11:53 Rev Time 0.00
Received By btrobaug Date 2003-01-31 Time 16:35 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-02-28 Cont ID  
Sent By kstevens Date 2003-02-27 Time 11:03 Rev Time 0.40
Received By pkrauss Date 2003-02-28 Time 14:35 Sent To B
Notes
2003-02-28 00:00:00MECHANICAL PERMIT 03012479

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-02-27 Cont ID  
Sent By dpalmer Date 2003-02-13 Time 07:29 Rev Time 0.25
Received By kstevens Date 2003-02-27 Time 11:03 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-02-11 Cont ID  
Sent By btrobaug Date 2003-01-31 Time 16:35 Rev Time 0.00
Received By sgraham Date   Time   Sent To I
Notes
***NONE***