| Plan Review Stops For Permit 03012265 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2003-05-19 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-08-13 |
Time |
14:05 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-05-19 |
Time |
13:23 |
Sent To |
|
|
| Notes |
| 2003-05-19 00:00:00 | NOA 01-1210.01 HAS MISSING PAGES AND IS | | | ILLEGIBLE AS WELL. | | | | | | AS NOTED ON THE PREVIOUS LIST, IF TEST | | | AND/OR ACCEPTANCE REPORTS ARE NOT | | | INCLUDED WITH THE ORIGINAL PERMIT | | | APPLICATION ASEPARATE PERMIT AND FEES | | | ARE REQUIRED. | | | | | | AS NOTED ON THE PREVIOUS LIST, THE | | | INFORMATION IS REQUIRED TO BE REVIEWED | | | BY THE | | | DESIGNER OF RECORD. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2003-05-12 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-16 |
Time |
11:18 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-05-12 |
Time |
16:36 |
Sent To |
|
|
| Notes |
| 2003-05-12 00:00:00 | PRODUCT APPROVALS SUBMITTED SUBSEQUENT | | | TO A BUILDING PERMIT BEING ISSUED | | | REQUIRE A SEPARATE PERMIT AND FEES. | | | | | | THE MIAMI DADE NOA 99-0224.05 IS | | | EXPIRED. | | | | | | THE NOA'S ARE REQUIRED TO BE REVIEWED BY | | | THE DESIGNER OF RECORD FOR CONFORMANCE | | | WITH HIS DESIGN. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2003-03-14 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-09 |
Time |
08:52 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-03-13 |
Time |
15:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-02-11 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-02-11 |
Time |
12:58 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-02-11 |
Time |
12:19 |
Sent To |
|
|
| Notes |
| 2003-02-11 00:00:00 | THE PROPOSED STAIRS ON SHEET A-2 DO NOT | | | COMPLY WITH FBC 1007.3.1.PLEASE REVISE | | | AS NECESSARY. | | | | | | WHAT IS THE INTENDED USE/OCCUPANCY OF | | | THE SEVERAL AREAS SHOWN ON THE PLAN? | | | SEE FBC 104.2. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2003-04-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-04-21 |
Time |
12:08 |
Rev Time |
1.50 |
| Received By |
dpalmer |
Date |
2003-04-21 |
Time |
12:08 |
Sent To |
|
|
| Notes |
| 2003-04-21 00:00:00 | INTERIOR 600A DISC`S REDLINED TO SHOW | | | PANELS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2003-04-10 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-15 |
Time |
16:15 |
Rev Time |
2.00 |
| Received By |
dpalmer |
Date |
2003-04-10 |
Time |
12:57 |
Sent To |
|
|
| Notes |
| 2003-04-10 00:00:00 | ************* UNSAT ************ | | | | | | 1)NOTE: PLEASE SEE COMMENTS FROM | | | PREVIOUS REVIEW. | | | | | | 2)NOTE: PLEASE SIZE SERVICE ENTRANCE | | | CONDUCTOR PER 240C-3 AND 310-16,110-14 | | | | | | 3)NOTE: PLEASE SEE CIRCUITING ON PLANS. | | | PLEASE CORRELATE CIRCUIT #`S ON PLANS | | | AND PANEL SCHEDULES. PANELS SHOW MORE | | | CIRCUITS THAN SHOWN ON PLANS? | | | | | | 4)NOTE: PLEASE SEE GUTTER SIZE. 12X12X24 | | | "? PLEASE ALSO SEE 110-26A-3 GUTTER MAY | | | NOT EXTEND6" INFRONT OF ELECTRICAL | | | EQUIPMENT.? | | | | | | PLEASE SEE ABOVE COMMENTS AND SUBMIT THE | | | ABOVE INFORMATION FOR REVIEW. IF THERE | | | ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2003-03-24 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-08 |
Time |
16:09 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2003-03-24 |
Time |
06:11 |
Sent To |
|
|
| Notes |
| 2003-03-24 00:00:00 | **************** UNSAT *************** | | | | | | PLEASE NOTE, NOW A COMPLETE NEW RISER | | | DIAGRAM WAS SUBMITTED. | | | MOST COMMENTS ARE NOW DUE TO FACT OF NEW | | | SERVICE BEING SHOWN. | | | | | | 1)NOTE: PLEASE SHOW VOLTAGE OF NEW | | | SERVICE. | | | | | | 2)NOTE: PLEASE CORRELATE PLANS AND RISER | | | DIAGRAM SUBMITTED. PLANS SHOW A SEPARATE | | | METER AND PANEL AT EACH BAY LOCATION.?? | | | RISER SHOWS ALL COMING FROM SAME | | | LOCATION.? | | | | | | 3)NOTE: PLEASE SEE 240-3C FOR SIZING | | | OF SERVICE ENTRANCE CONDUCTORS. 310-16 | | | | | | 4)NOTE: PLEASE SEE NOTE FOR GROUNDING | | | OF SERVICE TO BE AS PER FPL? PLEASE SHOW | | | GROUNDING PER NEC REQ`D UNDER 250-50. | | | | | | 5)NOTE: PLEASE SEE RISER, SOME OF THE | | | FEEDS TO BAYS ARE SHOWN COMING OUT OF | | | METERCAN? PLEASE SHOW COMING FROM DISC`S | | | LINE AND LOAD NOT PERMITTED IN METER | | | ENCLOSURE. | | | | | | 6)NOTE: PLEASE SUBMIT LOAD CALCULATIONS | | | FOR SERVICE. MIN TO BE SHOWN PER 220-3 | | | ,220-10,220-11,220-13. ETC PLEASE SHOW | | | ALL CONTINUOUS LOADS AT 125% PER 215-3 | | | 230-42. | | | | | | 7)NOTE: PLEASE VERFIY SIZING OF GUTTER | | | AND SIZE OF ELECTRICAL EQUIPMENT, IN | | | ORDER TO MEET 110-26 FOR CLEARENCE | | | INFRONT OF DISC`S AND METER. | | | | | | 8)NOTE: PLEASE SEE HOUSE PANEL SCHEDULE, | | | SHOWS CIRCUITS FOR EM/EXT LTS, IN EACH | | | BAY?. PLEASE NOTE, ELECTRICAL MAY NOT | | | CROSS OVER TO OTHER BAY AREAS. | | | PLEASE SHOW ALL CIRCUITING ON PLANS AND | | | CORRELATE WITH SUBMITTED PANEL SCHEDULES | | | PLEASE SEE 700-12E | | | 9)NOTE: PLEASE PROVIDE INFORMATION ON | | | PANEL SCHEDULES? VOLTAGE/SIZE ETC ETC. | | | | | | 10)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW EQUIPMENT. MAINS/BREAKERS/PANELS | | | ALL MUST BE RATED FOR THE AVAILABLE | | | FAULT CURRENT. 110-9/215-5 | | | | | | 11)NOTE: PLEASE SEE PANEL SCHEDULES, | | | SHOW 5 BRANCH CIRCUITS FOR LIGHTING AND | | | LIGHTING IS NOT SHOWN ON PLANS?? | | | | | | 12)NOTE: PLEASE SEE PANEL SCHEDULE | | | SHOWN AS TYPICAL,FOR UNITS 4&5, SHOWS A | | | CARGO ELEVATOR, IS THIS IN EACH BAY? | | | PLEASE ALSO SEE, ELEVATOR IS SHOWN AS | | | A 1-POLE BRKR?? PLEASE VERIFY. | | | | | | 13)NOTE: PLEASE SEE NOTE 12 ON E-1, | | | MENTIONS NEW SERVICE AT EACH BAY ALSO? | | | | | | 14)NOTE: PLEASE SEE E-1. NOTE 13 MENTION | | | -S HOUSE PANEL TO HAVE NO LOADS EXCEPT | | | OUTSIDE FLOODLIGHTS? AND HOUSE PANEL | | | SHOWS OTHER LOADS AND NO FLOOD LIGHTS?? | | | PLEASE CORRELATE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | PLEASE SEE FS/FAC 553-80(2)(B). PLEASE | | | SEE COPY OF FS ATTACHED. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-02-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-02-12 |
Time |
13:10 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2003-02-12 |
Time |
13:10 |
Sent To |
|
|
| Notes |
| 2003-02-12 00:00:00 | ************ UNSAT *************** | | | | | | PLEASE NOTE, THERE IS NOT ENOUGH | | | ELECTRICAL INFORMATION SHOWN FOR | | | COMPLETE REVIEW. PLANS SHOW NEW METERS, | | | PANEL ETC , BUT NO RISER DIAGRAM. | | | | | | PLEASE PROVIDE SEPARATION OF UNITS IN | | | ORDER TO ADD ADDTIONAL SERVICES UNDER | | | 230-2. | | | | | | PLEASE SHOW ALL LIGHTING IN COMMON AREA | | | THAT MAY BE INSTALLED? | | | | | | PLEASE SEE ANY FIRE REVIEW COMMENTS THAT | | | MAY AFFECT ELECTRICAL PLANS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2003-04-03 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2003-04-03 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-04-03 |
Time |
14:49 |
Sent To |
|
|
| Notes |
| 2003-04-03 00:00:00 | PER MEC 4/3/03 LS |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2003-02-07 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-02-07 |
Time |
12:22 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-02-07 |
Time |
12:22 |
Sent To |
|
|
| Notes |
| 2003-02-07 00:00:00 | 1) PLEASE INDICATE WHAT BUILDING THIS | | | IS AT THE SITE. | | | | | | 2) PLEASE INDICATE OCCUPANCY TYPE AND | | | EXISTING OCCUPANT LOADS. | | | | | | 3) TREADS AND RISERS ON NEW STAIRS DO | | | NOT MEET FIRE OR BUILDING CODES. | | | | | | 4) NO INFORMATION PROVIDED WITH THE | | | PLANS INDICATING IF THE BUILDING IS | | | FIRE SPRINKLER PROTECTED OR NOT. | | | | | | 5) PLEASE PROVIDE INFORMATION ON | | | DEMISING WALLS LOCATED WITHIN THE | | | BUILDING. | | | | | | 6) ELECTRICAL SPECIFICATIONS MAKES | | | REFERENCE TO EXIT SIGNS AND EMERGENCY | | | LIGHTING. PLEASE SHOW ALL EXISTING, | | | AND NEW LOCATIONS FOR THESE DEVICES. | | | | | | 6) PLEASE PROVIDE BUILDING DATA | | | INFORMATION. SIZE, CONSTRUCTION TYPE, | | | ANY TENANT SEPARATIONS, TRAVEL DISTANCES | | | FIRE PROTECTON, ETC. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2003-08-13 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2003-08-13 |
Time |
14:05 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2003-08-13 |
Time |
14:05 |
Sent To |
B |
|
| Notes |
| 2003-08-13 00:00:00 | TO HP DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2003-06-26 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-26 |
Time |
13:52 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-06-26 |
Time |
13:52 |
Sent To |
B |
|
| Notes |
| 2003-06-26 00:00:00 | HP DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2003-05-19 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-19 |
Time |
09:08 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-19 |
Time |
09:08 |
Sent To |
P |
|
| Notes |
| 2003-05-19 00:00:00 | KSTEVENS DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2003-05-16 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-16 |
Time |
11:18 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-16 |
Time |
11:18 |
Sent To |
B |
|
| Notes |
| 2003-05-16 00:00:00 | HP DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2003-05-09 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-09 |
Time |
08:52 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-09 |
Time |
08:52 |
Sent To |
B |
|
| Notes |
| 2003-05-09 00:00:00 | HP DESK.REVISION |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-04-15 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-15 |
Time |
16:15 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-04-15 |
Time |
16:15 |
Sent To |
E |
|
| Notes |
| 2003-04-15 00:00:00 | DP DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-04-08 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-08 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-04-08 |
Time |
16:08 |
Sent To |
E |
|
| Notes |
| 2003-04-08 00:00:00 | DP DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-03-13 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-03-13 |
Time |
11:52 |
Rev Time |
0.00 |
| Received By |
sthyng |
Date |
2003-03-13 |
Time |
11:52 |
Sent To |
|
|
| Notes |
| 2003-03-13 00:00:00 | COMM BOARD #15 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-01-30 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-01-30 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2003-01-29 |
Time |
14:37 |
Sent To |
|
|
| Notes |
| 2003-01-30 00:00:00 | COMM BOARD #1./WRT |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2003-02-12 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-02-12 |
Time |
16:41 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2003-02-12 |
Time |
16:35 |
Sent To |
|
|
| Notes |
| 2003-02-12 00:00:00 | NO MECHANICAL PLANS SUBMITTED FOR | | | REVIEW.PROVIDE CALCULATIONS FOR | | | VENTILATION REQUIREMENTS AS PER 2001 | | | FBC(M) TABLE 403.3 OR ASHRAE 62-89. | | | INDICATE OCCUPANCY TYPE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2003-05-27 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-05-27 |
Time |
15:20 |
Rev Time |
0.75 |
| Received By |
kstevens |
Date |
2003-05-24 |
Time |
11:37 |
Sent To |
|
|
| Notes |
| 2003-05-27 00:00:00 | REVISION OK - MOVED TOILET ROOM IN UNIT | | | #5 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2003-03-22 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-19 |
Time |
09:08 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2003-03-22 |
Time |
11:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-02-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-02-05 |
Time |
18:11 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-02-05 |
Time |
17:53 |
Sent To |
|
|
| Notes |
| 2003-02-05 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 11 | | | | | | 1) MORE INFORMATION REQUIRED. WILL EACH | | | UNIT BE FOR SEPARATE TENANT? IF SO THEN | | | EACH UNIT WILL BE REQUIRED TO HAVE IT'S | | | OWN WATER COOLER. | | | 2) SHT P&E-1 PLEASE SUBMIT A WATER RISER | | | DIAGRAM. WATER HAMMER ARRESTORS REQUIRED | | | BY SECTION 604.9 SHALL BE LOCATED NEAR | | | THE FIXTURE IN AN "EFFECTIVE RANGE" NOT | | | IN THE CEILING AT THE TOP OF THE DROP | | | PER PDI-WH 201 AND MANUF. INSTALLATION | | | INSTRUCTIONS. | | | 3) SHT P&E-1 NOTE #8 AIR CHAMBERS ARE | | | NOT APPROVED. PLEASE DELETE REFERENCE. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|