| Plan Review Stops For Permit 03012088 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2003-04-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-04-22 |
Time |
08:34 |
Rev Time |
1.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-03-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-02-25 |
Time |
06:00 |
Rev Time |
3.00 |
| Received By |
lhatten |
Date |
2003-03-08 |
Time |
18:44 |
Sent To |
|
|
| Notes |
| 2003-03-12 00:00:00 | 1) NEEDS N.O.C. | | | 2) NEEDS IMPACT FEES PAID | | | 3) NEEDS PRODUCT APPROVALS FOR ALL | | | EXTERIOR DOORS,SIDELITES,ARCH WINDOWS, | | | GARAGE DOORS,MULL BARS AND SHUTTER | | | LAYOUT FOR HOUSE | | | 4) ( 1 ) EXTRA COVER SHEET FROM ENERGY | | | CALS. | | | 5) ROOFING PRODUCT APPROVALS | | | 6)DECORATIVE WOOD LOUVER-24"RADIUS |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2004-05-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-05-18 |
Time |
15:19 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2004-05-18 |
Time |
15:19 |
Sent To |
|
|
| Notes |
| 2004-05-18 00:00:00 | REDLINED 220.3B-4 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2004-05-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2004-05-08 |
Time |
16:39 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2004-05-08 |
Time |
16:39 |
Sent To |
|
|
| Notes |
| 2004-05-08 00:00:00 | ****** UNSAT ********** | | | | | | 1)NOTE: PLEASE SEE FBC 104.2.1, PLANS | | | MUST CONTAIN PRINTED NAME AND SIGNATURE | | | OF PERSON RESPONSIBLE FOR PLANS. | | | PRINTED NAME IS PLANS, HOWEVER, MR JUAN | | | MOLINA NEEDS TO SIGN AND DATE. | | | | | | 2)NOTE: PLEASE SEE MISSING RECEPT ON | | | PLANS, ONE SHEET IS REDLINED. | | | | | | 3 )NOTE: PLEASE SEE 220.3B4. | | | PLEASE SHOW ALL RECESSED LTS BASED ON | | | MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT | | | BE FIGURED IN W/ 3W/PER SQ FT. | | | PLEASE PROVIDE FIXTURE INFORMATION ON | | | LEGEND. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2003-04-22 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-06 |
Time |
10:34 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-04-22 |
Time |
08:34 |
Sent To |
B |
|
| Notes |
| 2003-04-22 00:00:00 | PLANS REDLINED BY DESIGNER. | | | OLD SHEETS STILL NEED TO BE TAKEN OUT OF | | | SETS AND INSERT NEW SHEETS. | | | SENT BACK TO LOU MARTINEZ. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2003-04-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-04-10 |
Time |
05:53 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2003-04-10 |
Time |
05:53 |
Sent To |
P |
|
| Notes |
| 2003-04-10 00:00:00 | ************** UNSAT ********* | | | | | | PLEASE REMOVE ALL OLD SHEETS AND INSERT | | | NEW SHEETS TO MAKE TWO COMPLETE SETS FOR | | | REVIEW AND STAMPING. | | | | | | PLEASE SEE THE FOLLOWING COMMENTS THAT | | | STILL NEED TO BE ADDRESSED FROM FIRST | | | REVIEW. MOST WERE DONE. | | | | | | 1)NOTE: PLEASE SIZE SERVICE ENTRANCE | | | CONDUCTORS PER 310-15 FOR A 350A SERVICE | | | INTO GUTTER. THE CONDUCTORS SHOWN FROM | | | GUTTER TO MAINS ARE OK. | | | | | | 2)NOTE: PLEASE SEE MISSING RECEPT FOR | | | KITCHEN COUNTERSPACE. 210-52C-1 AND | | | PLEASE SHOW AS GFI/GFI PROTECTED. | | | 210-8A-6 | | | PLEASE SEE ONE SET W/ REDLINES. | | | | | | 3)NOTE: PLEASE CALL IN REF TO PANEL "B" | | | GROUNDING ELECTRODE, NOT REQ`D BUT IF | | | SHOWN ON PLAN, IT WILL BE REQ`D TO BE | | | INSTALLED. PLEASE CALL. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. IF A VOICE MAIL IS LEFT, | | | PLEASE LEAVE PHONE # FOR RETURN CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-02-25 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-08 |
Time |
16:25 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2003-02-25 |
Time |
05:59 |
Sent To |
B |
|
| Notes |
| 2003-02-25 00:00:00 | ****************** UNSAT *********** | | | | | | 1)NOTE: PLEASE SIZE SEVICE ENTRANCE | | | CONDUCTORS PER 310-15. 350A SERIVCE. | | | SHOWN AS 3/0`S INTO GUTTER AND 250MCM | | | IN GUTTER. | | | | | | 2)NOTE: PLEASE ALSO SIZE FEEDERS FOR | | | PANELS. SHOWN AS 1/0`S FOR 200A'S? | | | AND #2 FOR 150A'S. PLEASE ALSO SEE | | | 310-15 FOR MIN SIZE. ALSO 310-16 | | | | | | 3)NOTE: PLEASE VERIFY GROUNDING ELEC- | | | -TRODE SYSTEM AT PANEL "B". PLEASE CALL. | | | | | | 4)NOTE: PLEASE SHOW MAINS NEXT TO METER | | | ON PLANS (E-2) AS SHOWN ON RISER. | | | | | | 5)NOTE: PLEASE SEE MISSING OUTLETS | | | ON ISLAND AND COUNTERSPACES IN KITCHEN. | | | PER 210-52-C1,2,3,4,&5, | | | ALSOPENINSULAR. | | | | | | 6)NOTE: PLEASE ALSO SHOW ALL COUNTER- | | | -SPACE RECEPTS AS GFI/GFI PROTECTED | | | PER 210-8-A-6 | | | | | | 7)NOTE: PLEASE NOTE ON PLANS , ALL | | | SD'S TO BE A MIN OF 3' FROM BATHS PER | | | NFPA-72 8-1.4.2 | | | | | | 8)NOTE: PLEASE SEE MISSING GFI RECEPT | | | IN BATH #3. 210-52D | | | | | | 9)NOTE: PLEASE SHOW A/C DISC'S PER | | | 440-11 (COND UNITS). | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2004-05-06 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2004-05-06 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2004-05-06 |
Time |
10:34 |
Sent To |
E |
|
| Notes |
| 2004-05-06 00:00:00 | TO DP DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-05-09 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-09 |
Time |
09:37 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-05-09 |
Time |
09:37 |
Sent To |
P |
|
| Notes |
| 2003-05-09 00:00:00 | KSTEVENS DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-04-08 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-04-08 |
Time |
16:25 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-04-08 |
Time |
16:20 |
Sent To |
E |
|
| Notes |
| 2003-04-08 00:00:00 | DP DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-01-29 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2003-02-12 |
Time |
15:14 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2003-01-29 |
Time |
13:43 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2003-04-16 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-04-16 |
Time |
08:37 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2003-04-16 |
Time |
12:18 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2003-02-22 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2003-02-22 |
Time |
08:19 |
Rev Time |
0.50 |
| Received By |
hmoser |
Date |
2003-02-22 |
Time |
13:24 |
Sent To |
E |
|
| Notes |
| 2003-02-22 00:00:00 | PLAN DENIED | | | NEED DUCT SIZE NO MECHANICAL PLAN. | | | NEED GRILL SIZE AND CFM ON CANS. | | | PLAN REVIEW BY HAROLD MOSER | | | (561)659-8096 EXT.8221 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2003-05-20 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-05-20 |
Time |
10:58 |
Rev Time |
1.00 |
| Received By |
kstevens |
Date |
2003-05-20 |
Time |
10:58 |
Sent To |
|
|
| Notes |
| 2003-05-20 00:00:00 | PROVISO: NO HORIZONTAL DRY VENTS 905.3 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2003-04-16 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-05-09 |
Time |
09:37 |
Rev Time |
0.75 |
| Received By |
kstevens |
Date |
2003-04-16 |
Time |
08:34 |
Sent To |
M |
|
| Notes |
| 2003-04-16 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | 1) PLEASE REMOVE ALL OLD SHEETS AND PUT | | | NEW SHEETS FOR COMPLETE SETS TO REVIEW | | | AND STAMP. | | | 2) SEE ALL RED LINE AND HIGHLIGHTED | | | AREAS ON RISER DIAGRAM AND FLOOR PLAN | | | FLAT DRAWING. PLEASE MAKE CORRECTIONS | | | AND RESUBMIT. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 | | | (561) 805-6721 | | | FAX (561) 653-2692 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-02-22 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2003-02-22 |
Time |
08:19 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2003-02-22 |
Time |
08:19 |
Sent To |
M |
|
| Notes |
| 2003-02-22 00:00:00 | DENIED; | | | PLEASE SUBMIT A SANITARY RISER DIAGRAM. | | | DRAWING ON PAGE P-1 DOES NOT MEET CODE. | | | HORIZONTAL DRY VENTS. | | | UNVENTED FIXTURES. | | | PIPE NOT SIZED. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 659-8096 EXT.8369 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2003-02-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-01-29 |
Time |
13:44 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
I |
|
| Notes |
|
|