| Plan Review Stops For Permit 03011977 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2003-03-07 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-03-07 |
Time |
13:09 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-03-07 |
Time |
12:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-02-11 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-02-11 |
Time |
08:08 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-02-11 |
Time |
08:08 |
Sent To |
|
|
| Notes |
| 2003-02-11 00:00:00 | WHAT IS THE NATURE AND QUANTITY OF THE | | | COMMODITIES TO BE STORED?IF | | | MANUFACTURING IS TO TAKE PLACE PLEASE | | | PROVIDE A BRIEF DESCRIPTION OF THE | | | PROCESS.SEE FBC 104.3. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2003-02-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-02-07 |
Time |
06:57 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-02-07 |
Time |
06:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2003-03-13 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-03-13 |
Time |
15:48 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-03-13 |
Time |
15:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2003-02-07 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-02-07 |
Time |
11:05 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-02-07 |
Time |
11:05 |
Sent To |
|
|
| Notes |
| 2003-02-07 00:00:00 | 1) ENSURE TENANT IDENTIFIER IS PRESENT | | | FOR POLICE AND FIRE RESCUE. | | | | | | 2) PLANS,PERMIT APPLICATION, AND PLAN | | | REVIEW ALL LIST DIFFERENT ADDRESSES. | | | PLEASE CORRECT. | | | | | | 3) EMERGENCY LIGHTING NOT REQUIRED | | | IN SMALL OFFICES. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-03-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-03-05 |
Time |
10:56 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2003-03-05 |
Time |
10:56 |
Sent To |
|
|
| Notes |
| 2003-03-05 00:00:00 | TO COMM BOARD #21 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2003-03-12 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-03-12 |
Time |
10:33 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2003-03-12 |
Time |
10:33 |
Sent To |
|
|
| Notes |
| 2003-03-12 00:00:00 | PROVISO: | | | | | | EQUIPMENT LOCATED ON ROOFS AT A HEIGHT | | | EXCEEDING 16 FT, SHALL HAVE A PERMANENT | | | MEANS OF ACCESS.ACCESS SHALL NOT | | | REQUIREDCLIMBING OVER OBSTRUCTIONS | | | GREATER THAN 30". | | | | | | CONDENSATE SHALL DISCHARGE TO ROOFDRAIN. | | | CONDENSATE DUMPING ONTO THE ROOFTOP IS | | | A SAFETY HAZARD. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2003-02-13 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-02-13 |
Time |
08:38 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2003-02-13 |
Time |
08:19 |
Sent To |
|
|
| Notes |
| 2003-02-13 00:00:00 | DENIED:MECHANICAL PERMIT 03011980 | | | | | | PROVIDE INFORMATION FOR THE CONDENSATE | | | (LINE SIZE & MATERIAL, LAYOUT AND | | | TERMINATION POINT). | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2003-03-26 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-03-26 |
Time |
10:46 |
Rev Time |
2.00 |
| Received By |
kstevens |
Date |
2003-03-21 |
Time |
09:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-02-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-02-05 |
Time |
10:01 |
Rev Time |
0.75 |
| Received By |
kstevens |
Date |
2003-02-05 |
Time |
10:01 |
Sent To |
|
|
| Notes |
| 2003-02-05 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 11 | | | | | | 1) SHT A-1 SEPARATE TOILET FACILITIES | | | ARE REQUIRED PER SECTION 403.2 | | | 2) SHT A-1 WATER COOLER SHALL COMPLY | | | WITH ARI-1010 PER SECTION 410.1. MANUF. | | | INFORMATION REQUIRED AT FINAL. | | | 3) SHT A-1 EMERGENCY EYE WASH/SHOWER, | | | MANUF. INFORMATION REQUIRED FOR REVIEW. | | | 4) SHT P1 PLUMBING SPECIFICATIONS #7, | | | AIR CHAMBERS NOT APPROVED. PLEASE DELETE | | | FROM REFERENCE. | | | 5) SHT P1 WATER RISER, AIR CHAMBERS ARE | | | NOT APPROVED. IF WATER HAMMER ARRESTORS | | | ARE USED, (SEC 604.9), THEY SHALL BE | | | LOCATED NEAR THE FIXTURE IN AN "EFFECT- | | | IVE RANGE" NOT AT THE TOP OF THE DROP IN | | | THE CEILING. | | | 6) SHT P1 SANITARY RISER & FLAT PLAN, | | | ONLY THE FIXTURES WITHIN THE BATHROOM | | | GROUP SHALL CONNECT TO THE WET-VENTED | | | HORIZONTAL BRANCH DRAIN. ANY ADDITIONAL | | | FIXTURES SHALL DISCHARGE DOWNSTREAM OF | | | THE WET VENT. SECTION 909.1 - THE JANIT- | | | OR SINK SHOULD HAVE ITS OUN VENT LINE | | | AND TIE IN DOWNSTREAM OF THE BATHROOM | | | GROUP. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|