Plan Review Details - Permit 03011850
Plan Review Stops For Permit 03011850
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2003-06-03 Cont ID  
Sent By sthyng Date 2003-06-03 Time 14:26 Rev Time 0.50
Received By sthyng Date 2003-06-03 Time 14:26 Sent To  
Notes
2003-06-03 00:00:00REVISION - ATTACHMENTS OF GIRDER TRUSS
 TO WOOD BEAM; FRAME WALL W/BEAM
 DESCRIPTION; SHEET A-100

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2003-03-25 Cont ID  
Sent By shernand Date 2003-06-02 Time 14:13 Rev Time 3.00
Received By sthyng Date 2003-03-25 Time 10:44 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2003-03-10 Cont ID  
Sent By dpalmer Date 2003-03-18 Time 06:06 Rev Time 3.00
Received By sthyng Date 2003-03-10 Time 13:18 Sent To  
Notes
2003-03-10 00:00:00**********CORRECTIONS************
  
 1.)PROVIDE PRODUCT APPROVALS FOR THE
 FRONT DOOR TO BE RELOCATED IF THE DOOR
 IS TO RELOCATED TO AN EXTERIOR WALL.
  
 2.)PROVIDE PRODUCT APPROVALS FOR
 THE WINDOWS TO BE RELOCATED IF THEY
 ARE TO BE USED IN AN EXTERIOR WALL.
  
 3.)PROVIDE PRODUCT APPROVALS FOR
 THE MULLIONS TO BE USED TO JOIN THE
 WINDOWS TOGETHER.
  
 4.)TWO COPIES OF ALL DOCUMENTATION
 MUST BE SUBMITTED AS PART OF THE PERMIT
 APPLICATION.PLEASE SUBMIT A SECOND
 COPY OF THE FOLLOWING ITEMS ALREADY
 SUBMITTED:
 A.ENERGY CALCS
 B.ROOF PRODUCT APPROVAL
 C.HURRICANE STORM PANEL PRODUCT
 APPROVALS
 D.ALL WINDOW PRODUCT APPROVALS
 E.FRENCH DOOR PRODUCT APPROVAL
  
 5.)PLEASE NOTE THAT THE PRODUCT
 APPROVAL SUBMITTED FOR THE FRENCH DOOR
 IS FOR A DOOR ONLY, WITHOUT SIDELITES.
 PLEASE SUBMIT THE CORRECT PRODUCT
 APPROVAL FOR THE PRODUCT SPECIFIED.
  
 6.)PROVIDE A DETAIL FOR THE NEW
 EXTERIOR STEPS ON THE NORTH ELEVATION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 LEA SMITH OR SAMANTHA THYNG
 561-659-8096, EXTENSION 8340

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2003-02-12 Cont ID  
Sent By dpalmer Date 2003-03-07 Time 14:17 Rev Time 1.50
Received By lsmith Date   Time   Sent To  
Notes
2003-02-10 00:00:00*********************PROVISO***********
  
 1. NEED PRODUCT APPROVALS FOR FIXED
 GLASS WINDOWS SHOWN ON PLANS.
 2. NEED ENERGY CALC. FOR ADD'L LIVING
 AREA.
 3. PLUMBING PERMIT & PLANS REQUIRED
 SEPARATELY INCLUDING SANITARY RISER.
 4. NEED HISTORIC SIGNOFF ON ROOF MATERIA
 LS PER SHERRY PILAND
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 659-8096 EXT. 8394

Review Stop E ELECTRICAL
Rev No 3 Status N Date 2003-03-18 Cont ID  
Sent By dpalmer Date 2003-03-18 Time 06:06 Rev Time 0.25
Received By dpalmer Date 2003-03-18 Time 06:06 Sent To B
Notes
2003-03-18 00:00:00************ NO ELECTRICAL REVIEW*****
 SEPARATE PERMIT AND PLANS UNDER SUB.

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2003-03-07 Cont ID  
Sent By sthyng Date 2003-03-17 Time 16:04 Rev Time 0.50
Received By dpalmer Date 2003-03-07 Time 14:17 Sent To B
Notes
2003-03-07 00:00:00************** UNSAT ******************
  
 PLEASE SEE ALL NOTES FROM FIRST REVIEW.
 PLEASE SEE PLANS, THEY ARE THE SMAE ONES
 THAT CAME IN FOR FIRST REVIEW??
  
 PLEASE MAKE CORRECTIONS AND SUBMIT FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 PLEASE SEE ATTACHED LETTER AS TO DESIGN
 PROFESSIONALS UNDER FS 553.80(2)(B)
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2003-02-11 Cont ID  
Sent By dpalmer Date 2003-03-05 Time 11:31 Rev Time 0.50
Received By dpalmer Date 2003-02-11 Time 15:19 Sent To B
Notes
2003-02-11 00:00:00************ UNSAT ****************
  
 1) NOTE: PLEASE SHOW ALL OUTLETS SERVING
 KITCHEN COUNTERSPACE AS GFI/GFI PROTECT-
 -ED PER 210-8-A-6.
 INCLUDES KITCHEN ISLANDS.
  
 2) NOTE: PLEASE SHOW ALL OUTLETS SERVING
 KITCHEN COUNTERSPACE AS GFI/GFI PROTECT-
 -ED PER 210-8-A-6.
 INCLUDES KITCHEN ISLANDS.
  
 3) NOTE: SMOKE DETECTORS ARE REQUIRED
 INSIDE AND OUTSIDE ALL SLEEPING ROOMS.
 ALSO ON EACH LEVEL OF A MULTI-LEVEL
 DWELLING UNIT. ROOMS WITH BATHS AND OR
 CLOSETS ARE CONSIDERED SLEEPING ROOMS.
 PER NFPA-72 8-1.4.2
 IN THE VICINITY OF BEDROOMS AND CLOSE
 PROXIMITY OF STAIRWAY.
 3'FT FROM BATHS/KITCHENS.
  
 4) NOTE: PLEASE SHOW ALL OUTLET SPACING
 TO MEET 2`,6`,12` RULE PER 210-52.
  
 5 ) NOTE: PLEASE NOTE FRONT AND REAR
 RECEPTS REQ`D PER 210-52E
  
 6 )NOTE: PLEASE LIST THE REQ`D ARC
 FAULT PROTECTED CIRCUITS ON PANEL
 SCHEDULE OR NOTE ON PLANS FOR BRANCH
 CIRCUIT PROTECTION. PER 210-12
  
 7)NOTE: PLEASE SHOW BATHS PER 210-52D
 210-11-C3
  
 8)NOTE: PLEASE SUBMIT PANEL SCHEDULE
 SHOWING ALL MIN REQ`D CIRCUITS PER
 210-52/210-11 ECT.
  
 PLEASE COMPLETE PLANS AND SUBMIT THE
 ABOVE INFORMATION FOR REVIEW. IF THERE
 ARE ANY QUESTIONS,PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2003-06-02 Cont ID  
Sent By shernand Date 2003-06-02 Time 14:13 Rev Time 0.00
Received By shernand Date 2003-06-02 Time 14:13 Sent To B
Notes
2003-06-02 00:00:00STHYNG DESK

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2003-03-17 Cont ID  
Sent By sthyng Date 2003-03-17 Time 16:04 Rev Time 0.00
Received By sthyng Date 2003-03-17 Time 16:04 Sent To E
Notes
2003-03-17 00:00:00TO DP DESK

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2003-03-14 Cont ID  
Sent By sthyng Date 2003-03-14 Time 13:26 Rev Time 0.00
Received By sthyng Date 2003-03-14 Time 13:26 Sent To E
Notes
2003-03-14 00:00:00TO DP DESK

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-03-05 Cont ID  
Sent By dpalmer Date 2003-03-05 Time 11:31 Rev Time 0.00
Received By dpalmer Date 2003-03-05 Time 11:31 Sent To E
Notes
2003-03-05 00:00:00TO DVP'S DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-02-06 Cont ID  
Sent By dpalmer Date 2003-02-06 Time 15:46 Rev Time 0.00
Received By dpalmer Date 2003-02-06 Time 15:46 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-01-31 Cont ID  
Sent By btrobaug Date 2003-01-31 Time 15:56 Rev Time 0.00
Received By btrobaug Date 2003-01-31 Time 15:56 Sent To Z
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-01-24 Cont ID  
Sent By dpalmer Date 2003-01-24 Time 11:08 Rev Time 0.00
Received By dpalmer Date 2003-01-24 Time 11:08 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-02-08 Cont ID  
Sent By kstevens Date 2003-02-06 Time 17:03 Rev Time 0.50
Received By hmoser Date 2003-02-08 Time 10:58 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2003-02-06 Cont ID  
Sent By dpalmer Date 2003-02-06 Time 15:46 Rev Time 0.33
Received By kstevens Date 2003-02-06 Time 16:52 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2003-02-06 Cont ID  
Sent By sgraham Date 2003-02-06 Time 14:48 Rev Time 0.00
Received By sgraham Date   Time   Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2003-01-27 Cont ID  
Sent By btrobaug Date 2003-01-31 Time 15:56 Rev Time 0.00
Received By sgraham Date   Time   Sent To  
Notes
2003-01-27 00:00:00DENIED BY ZONING, NEEDSITE PLAN
 SHOWING THE ADDITIONS