| Plan Review Stops For Permit 03011850 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2003-06-03 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-06-03 |
Time |
14:26 |
Rev Time |
0.50 |
| Received By |
sthyng |
Date |
2003-06-03 |
Time |
14:26 |
Sent To |
|
|
| Notes |
| 2003-06-03 00:00:00 | REVISION - ATTACHMENTS OF GIRDER TRUSS | | | TO WOOD BEAM; FRAME WALL W/BEAM | | | DESCRIPTION; SHEET A-100 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2003-03-25 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-02 |
Time |
14:13 |
Rev Time |
3.00 |
| Received By |
sthyng |
Date |
2003-03-25 |
Time |
10:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2003-03-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-03-18 |
Time |
06:06 |
Rev Time |
3.00 |
| Received By |
sthyng |
Date |
2003-03-10 |
Time |
13:18 |
Sent To |
|
|
| Notes |
| 2003-03-10 00:00:00 | **********CORRECTIONS************ | | | | | | 1.)PROVIDE PRODUCT APPROVALS FOR THE | | | FRONT DOOR TO BE RELOCATED IF THE DOOR | | | IS TO RELOCATED TO AN EXTERIOR WALL. | | | | | | 2.)PROVIDE PRODUCT APPROVALS FOR | | | THE WINDOWS TO BE RELOCATED IF THEY | | | ARE TO BE USED IN AN EXTERIOR WALL. | | | | | | 3.)PROVIDE PRODUCT APPROVALS FOR | | | THE MULLIONS TO BE USED TO JOIN THE | | | WINDOWS TOGETHER. | | | | | | 4.)TWO COPIES OF ALL DOCUMENTATION | | | MUST BE SUBMITTED AS PART OF THE PERMIT | | | APPLICATION.PLEASE SUBMIT A SECOND | | | COPY OF THE FOLLOWING ITEMS ALREADY | | | SUBMITTED: | | | A.ENERGY CALCS | | | B.ROOF PRODUCT APPROVAL | | | C.HURRICANE STORM PANEL PRODUCT | | | APPROVALS | | | D.ALL WINDOW PRODUCT APPROVALS | | | E.FRENCH DOOR PRODUCT APPROVAL | | | | | | 5.)PLEASE NOTE THAT THE PRODUCT | | | APPROVAL SUBMITTED FOR THE FRENCH DOOR | | | IS FOR A DOOR ONLY, WITHOUT SIDELITES. | | | PLEASE SUBMIT THE CORRECT PRODUCT | | | APPROVAL FOR THE PRODUCT SPECIFIED. | | | | | | 6.)PROVIDE A DETAIL FOR THE NEW | | | EXTERIOR STEPS ON THE NORTH ELEVATION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | LEA SMITH OR SAMANTHA THYNG | | | 561-659-8096, EXTENSION 8340 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2003-02-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-03-07 |
Time |
14:17 |
Rev Time |
1.50 |
| Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-02-10 00:00:00 | *********************PROVISO*********** | | | | | | 1. NEED PRODUCT APPROVALS FOR FIXED | | | GLASS WINDOWS SHOWN ON PLANS. | | | 2. NEED ENERGY CALC. FOR ADD'L LIVING | | | AREA. | | | 3. PLUMBING PERMIT & PLANS REQUIRED | | | SEPARATELY INCLUDING SANITARY RISER. | | | 4. NEED HISTORIC SIGNOFF ON ROOF MATERIA | | | LS PER SHERRY PILAND | | | ANY QUESTIONS PLEASE CALL: | | | LEA SMITH, BUILDING PLANS EXAMINER | | | 659-8096 EXT. 8394 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
N |
Date |
2003-03-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-03-18 |
Time |
06:06 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2003-03-18 |
Time |
06:06 |
Sent To |
B |
|
| Notes |
| 2003-03-18 00:00:00 | ************ NO ELECTRICAL REVIEW***** | | | SEPARATE PERMIT AND PLANS UNDER SUB. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2003-03-07 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-03-17 |
Time |
16:04 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-03-07 |
Time |
14:17 |
Sent To |
B |
|
| Notes |
| 2003-03-07 00:00:00 | ************** UNSAT ****************** | | | | | | PLEASE SEE ALL NOTES FROM FIRST REVIEW. | | | PLEASE SEE PLANS, THEY ARE THE SMAE ONES | | | THAT CAME IN FOR FIRST REVIEW?? | | | | | | PLEASE MAKE CORRECTIONS AND SUBMIT FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | PLEASE SEE ATTACHED LETTER AS TO DESIGN | | | PROFESSIONALS UNDER FS 553.80(2)(B) | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2003-02-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-03-05 |
Time |
11:31 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-02-11 |
Time |
15:19 |
Sent To |
B |
|
| Notes |
| 2003-02-11 00:00:00 | ************ UNSAT **************** | | | | | | 1) NOTE: PLEASE SHOW ALL OUTLETS SERVING | | | KITCHEN COUNTERSPACE AS GFI/GFI PROTECT- | | | -ED PER 210-8-A-6. | | | INCLUDES KITCHEN ISLANDS. | | | | | | 2) NOTE: PLEASE SHOW ALL OUTLETS SERVING | | | KITCHEN COUNTERSPACE AS GFI/GFI PROTECT- | | | -ED PER 210-8-A-6. | | | INCLUDES KITCHEN ISLANDS. | | | | | | 3) NOTE: SMOKE DETECTORS ARE REQUIRED | | | INSIDE AND OUTSIDE ALL SLEEPING ROOMS. | | | ALSO ON EACH LEVEL OF A MULTI-LEVEL | | | DWELLING UNIT. ROOMS WITH BATHS AND OR | | | CLOSETS ARE CONSIDERED SLEEPING ROOMS. | | | PER NFPA-72 8-1.4.2 | | | IN THE VICINITY OF BEDROOMS AND CLOSE | | | PROXIMITY OF STAIRWAY. | | | 3'FT FROM BATHS/KITCHENS. | | | | | | 4) NOTE: PLEASE SHOW ALL OUTLET SPACING | | | TO MEET 2`,6`,12` RULE PER 210-52. | | | | | | 5 ) NOTE: PLEASE NOTE FRONT AND REAR | | | RECEPTS REQ`D PER 210-52E | | | | | | 6 )NOTE: PLEASE LIST THE REQ`D ARC | | | FAULT PROTECTED CIRCUITS ON PANEL | | | SCHEDULE OR NOTE ON PLANS FOR BRANCH | | | CIRCUIT PROTECTION. PER 210-12 | | | | | | 7)NOTE: PLEASE SHOW BATHS PER 210-52D | | | 210-11-C3 | | | | | | 8)NOTE: PLEASE SUBMIT PANEL SCHEDULE | | | SHOWING ALL MIN REQ`D CIRCUITS PER | | | 210-52/210-11 ECT. | | | | | | PLEASE COMPLETE PLANS AND SUBMIT THE | | | ABOVE INFORMATION FOR REVIEW. IF THERE | | | ARE ANY QUESTIONS,PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2003-06-02 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-02 |
Time |
14:13 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-06-02 |
Time |
14:13 |
Sent To |
B |
|
| Notes |
| 2003-06-02 00:00:00 | STHYNG DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2003-03-17 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-03-17 |
Time |
16:04 |
Rev Time |
0.00 |
| Received By |
sthyng |
Date |
2003-03-17 |
Time |
16:04 |
Sent To |
E |
|
| Notes |
| 2003-03-17 00:00:00 | TO DP DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2003-03-14 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-03-14 |
Time |
13:26 |
Rev Time |
0.00 |
| Received By |
sthyng |
Date |
2003-03-14 |
Time |
13:26 |
Sent To |
E |
|
| Notes |
| 2003-03-14 00:00:00 | TO DP DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-03-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-03-05 |
Time |
11:31 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2003-03-05 |
Time |
11:31 |
Sent To |
E |
|
| Notes |
| 2003-03-05 00:00:00 | TO DVP'S DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-02-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-02-06 |
Time |
15:46 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2003-02-06 |
Time |
15:46 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-01-31 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-01-31 |
Time |
15:56 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2003-01-31 |
Time |
15:56 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-01-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-01-24 |
Time |
11:08 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2003-01-24 |
Time |
11:08 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2003-02-08 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-02-06 |
Time |
17:03 |
Rev Time |
0.50 |
| Received By |
hmoser |
Date |
2003-02-08 |
Time |
10:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2003-02-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-02-06 |
Time |
15:46 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2003-02-06 |
Time |
16:52 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2003-02-06 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2003-02-06 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2003-01-27 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-01-31 |
Time |
15:56 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-01-27 00:00:00 | DENIED BY ZONING, NEEDSITE PLAN | | | SHOWING THE ADDITIONS |
|
|