| Plan Review Stops For Permit 03011187 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2003-06-30 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-06-30 |
Time |
12:17 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2003-06-30 00:00:00 | REVIEWED AGAIN 6/27/03 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2003-03-14 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2003-03-14 |
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2003-03-14 |
Time |
12:01 |
Sent To |
|
|
| Notes |
| 2003-03-14 00:00:00 | PLANS DATED 2/26/03 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2003-03-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2003-01-28 |
Time |
13:28 |
Rev Time |
1.25 |
| Received By |
hpiskura |
Date |
2003-01-28 |
Time |
13:28 |
Sent To |
|
|
| Notes |
| 2003-01-28 00:00:00 | | | | BUILDING PLAN REVIEW | | | PERMIT: 03011187 | | | ADD: 700 S ROSEMARY # 113 | | | ARCH: HVC ARCHITECTS ( MICHAEL) | | | TEL: (305)567-0602 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | 1) 11-4.23.3 CLEAR FLOOR SPACE. A UNOBST | | | RUCTEDTURNING SPACE COMPLYING WITH | | | 11-4.2.3 SHALL PROVIDED WITHIN AN ACCESS | | | IBLE BATHROOM. | | | | | | 2)704.2.1.4 CORRIDOR PARTITIONS, SMOKE | | | STOP PARTITIONS, HORIZONTAL EXIT PART- | | | ITIONS, EXIT ENCLOSURES, AND FIRE | | | RATED WALLS REQUIRED TO HAVE PROTECTED | | | OPENINGS SHALL BE EFFECTIVELY AND | | | PERMANETLY IDENTIFIED WITH SIGNS OR | | | STENCILING IN A MANNER ACCEPTABLE TO THE | | | AUTHORITY HAVING JURISDICTION. SUCH IDEN | | | TIFICATION SHALL BE ABOVE ANY DECORATIVE | | | CEILING CEILING AND IN CONCEALED SPACES. | | | SUGGESTED WORDING" FIRE & SMOKE BARRIER | | | PROTECT ALL OPENINGS". | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | (561)659-8096 X 8412 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2003-06-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-06-16 |
Time |
16:46 |
Rev Time |
0.50 |
| Received By |
dpalmer |
Date |
2003-06-16 |
Time |
16:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2003-03-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-03-18 |
Time |
17:40 |
Rev Time |
0.25 |
| Received By |
dpalmer |
Date |
2003-03-18 |
Time |
17:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2003-01-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2003-01-27 |
Time |
16:38 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2003-01-27 |
Time |
16:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2003-06-30 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2003-06-30 |
Time |
10:45 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2003-06-30 |
Time |
10:45 |
Sent To |
|
|
| Notes |
| 2003-06-30 00:00:00 | **************PROVISO**************** | | | SEPARATE PLANS AND PERMITS REQUIRED FOR | | | FIRE ALARM AND FIRE SPRINKLER SYSTEMS | | | REVISION. | | | | | | NATE MCCRAY, CAPTAIN | | | 805-6722 OR 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2003-04-02 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-04-02 |
Time |
09:15 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-04-02 |
Time |
09:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2003-01-23 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2003-01-23 |
Time |
15:34 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2003-01-23 |
Time |
15:34 |
Sent To |
|
|
| Notes |
| 2003-01-23 00:00:00 | 1) PLEASE PROVIDE A STROBE IN THE | | | PRIVATE BATHROOM. | | | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2003-08-26 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-08-26 |
Time |
08:22 |
Rev Time |
0.00 |
| Received By |
csiegber |
Date |
2003-08-26 |
Time |
08:22 |
Sent To |
M |
|
| Notes |
| 2003-08-26 00:00:00 | TO PK DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2003-06-30 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-06-30 |
Time |
09:39 |
Rev Time |
0.00 |
| Received By |
sthyng |
Date |
2003-06-30 |
Time |
09:39 |
Sent To |
|
|
| Notes |
| 2003-06-30 00:00:00 | TAKEN OFF OF BOARD, SENT TO FIRE (NM | | | DESK) |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2003-06-06 |
|
|
Cont ID |
|
| Sent By |
shernand |
Date |
2003-06-06 |
Time |
11:32 |
Rev Time |
0.00 |
| Received By |
shernand |
Date |
2003-06-06 |
Time |
11:32 |
Sent To |
|
|
| Notes |
| 2003-06-06 00:00:00 | COMM BOARD #42 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2003-03-13 |
|
|
Cont ID |
|
| Sent By |
sthyng |
Date |
2003-03-13 |
Time |
13:31 |
Rev Time |
0.00 |
| Received By |
sthyng |
Date |
2003-03-13 |
Time |
13:31 |
Sent To |
|
|
| Notes |
| 2003-03-13 00:00:00 | COMM BOARD #30 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2003-01-17 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2003-01-17 |
Time |
18:35 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2003-01-16 |
Time |
18:35 |
Sent To |
|
|
| Notes |
| 2003-01-17 00:00:00 | COM BOARD#28./WRT |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2003-06-27 |
|
|
Cont ID |
|
| Sent By |
csiegber |
Date |
2003-08-26 |
Time |
08:22 |
Rev Time |
0.50 |
| Received By |
hmoser |
Date |
2003-06-27 |
Time |
16:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2003-03-18 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-03-18 |
Time |
16:24 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2003-03-18 |
Time |
16:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2003-02-03 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2003-02-03 |
Time |
15:54 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2003-02-03 |
Time |
15:47 |
Sent To |
|
|
| Notes |
| 2003-02-03 00:00:00 | DENIED: | | | | | | CLARIFY MAKE-UP AIR TO NEW BATHROOM. | | | THE AMOUNT OF SUPPLY AIR SHALL BE | | | APPROXIMATELY EQUAL TO THE AMOUNT OF | | | AIR EXHAUSTED.2001 FBC(M) 403.1 | | | | | | PLAN SHEET A.1 WALL LEGEND "EXISTING 1 | | | HR" RATED CONSTRUCTION.FIRE DAMPERS | | | ARE REQUIRED ON DUCTS PENETRATING WALLS | | | HAVING A FIRE RESISTANCE RATING OF 1 HR | | | OR MORE.2001 FBC(M) 607.1.2 #1. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2003-06-27 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-06-27 |
Time |
14:44 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2003-06-27 |
Time |
14:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2003-03-26 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-03-26 |
Time |
11:04 |
Rev Time |
0.25 |
| Received By |
kstevens |
Date |
2003-03-26 |
Time |
11:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2003-01-25 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2003-01-25 |
Time |
06:27 |
Rev Time |
0.33 |
| Received By |
kstevens |
Date |
2003-01-25 |
Time |
06:27 |
Sent To |
|
|
| Notes |
| 2003-01-25 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 CHAPTER 11 | | | | | | 1) SHT A-1 TOILET ROOM, AN UNOBSTRUCTED | | | TURNING SPACE SHALL BE PROVIDED WITHIN | | | AN ACCESSIBLE TOILET ROOM COMPLYING WITH | | | 11-4.3.2. | | | 2) SHT M.E.P. PLEASE PROVIDE A SANITARY | | | RISER DIAGRAM AND A WATER RISER DIAGRAM. | | | SHOW ALL PIPE SIZES, AND VENT TERMINAT- | | | ION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|