Plan Review Details - Permit 03010610
Plan Review Stops For Permit 03010610
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2003-10-07 Cont ID  
Sent By jwitmer Date 2003-10-07 Time 16:34 Rev Time 0.50
Received By jwitmer Date 2003-10-07 Time 16:34 Sent To  
Notes
2003-10-07 00:00:00REVISION# 10-02-03JW

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2003-09-16 Cont ID  
Sent By csiegber Date 2003-10-03 Time 10:54 Rev Time 0.33
Received By jwitmer Date 2003-09-16 Time 15:02 Sent To  
Notes
2003-09-16 00:00:00REVISION FOOTING OK JW

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-06-19 Cont ID  
Sent By csiegber Date 2003-09-15 Time 13:56 Rev Time 0.75
Received By jwitmer Date 2003-06-19 Time 08:58 Sent To  
Notes
2003-06-19 00:00:00************BUILDING PROVISO************
 PERMIT: 03010610
 ADDRESS: 217 SUNSET ROAD
 CONT: O/B CHRISTODOULIDES, CHRIS
  
 1) PLANS REVIEWED WITH THE UNDERSTANDING
 WINDOWS ARE CASEMENT & FIXED WINDOWS.
 2) THE PROPOESD 2ND FLOOR WINDOWS
 (EMERGENCY EGRESS) MEET CODE.
 3) PROVIDE PRODUCT APPROVALS FOR THE
 FOLLOWING BEFORE ROUGH BUCK INSPECTION:
 A) IMPACT RESISTANT MULLION (IF USED)
 B) EXTERIOR DOOR
 JIM WITMER
 (561)805-6715

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-02-11 Cont ID  
Sent By dpalmer Date 2003-02-10 Time 10:57 Rev Time 2.25
Received By jwitmer Date 2003-02-11 Time 06:54 Sent To  
Notes
2003-02-11 00:00:00BUILDING PLAN REVIEW
 PERMIT: 03010610
 ADD: 217 SUNSET ROAD
 CONT: O/B CHRISTODOULIDERS, DHRIS
 TEL: (561)833-3660
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 PROVIDE NOC RECORDED WITH THE CLERK
 OF COURT BEFORE A PERMIT CAN BE ISSUED.
  
 PLANS, SPECIFICATIONS,REPORTS OR
 OTHER DOCUMENTS PREPARED BY THE DESIGN
 PROFESSIONAL AND BEING FILED FOR PUBLIC
 RECORD SHALL HAVE THE SIGNATURE AND
 SEAL OF THE DESIGN PROFESSIONAL AFFIXED
 TO THE DOCUMENT.
 FL STATE STAT: 61G15-23.002 ENGINEERS
 FL ATATE STAT: 61G16.003 ARCHITECTS
  
 PROVIDE ENERGY CALCULATIONS AND
 EQUIPMENT SIZING CALCULATIONS (MANUAL J)
 AS REQUIRED BY THE 2001 FLORIDA ENERGY
 EFFICIENTCY CODE FOR BUILDING CONSTRUC-
 TION.
  
 FL BLD CODE 104.2.1.2
 ADDITIONAL INFORMATION REQUIRED,
 SHEET 3 DETAIL A/2 INDICATES A WOOD
 FRAME WALL, WHERE IS THIS LOCATED? ALL
 EXTERIOR WALLS ARE BLOCK.
  
 1606.1.4(1) IN WIND BORNE DEBRIS
 REGIONS, EXTERIOR GLAZING THAT RECEIVES
 POSITIVE PRESSURE IN BUILDINGS SHALL BE
 ASSUMED TO BE OPENINGS UNLESS SUCH
 GLAZING IS IMPACT RESISTANT OR PROTECTED
 WITH AN IMPACT RESISTANT COVERING MEET-
 ING THE REQUIREMENTS OF SSTD 12, ASTM
 E 1886 AND ASTM E 1996 OR MIAMI-DADE.
  
 1) GLAZED OPENINGS LOCATED WITHIN 30 FT
 OF GRADE SHALL MEET THE REQUIREMENTS OF
 LARGE MISSLE TEST.
  
 FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORT, SBCCI OR DADE COUNTY
 REPORT ARE ACCEPTED.MISSING REPORTS:
 A)WINDOWS
 B)EXTERIOR DOOR
 C) ROOFING ASSEMBLIES
 D) STORM SHUTTERS
  
 1606.4.4 ANCHOR METHODS. PROVIDE
 INFORMATION FOR INSTALLATION OF DOOR
 AND WINDOW BUCKS.
  
 1707.4.3 EACH EXTERIOR DOOR
 ASSEMBLY NOT COVERED BY 1707.4.2
 (GLAZED DOORS) SHALL BE LISTED AND TEST-
 ED FOR A PERIOD EQUAL TO THE QUANITY
 3600/ V WHERE THE TIME PERIOD IS IN
 SECTIONS AND V IS IN MILES PER HR TAKEN
 FROM FIGURE 1606. THE TIME PERIOD SHALL
 ALSO INCLUDE A 10 SECOND PERIOD AT A
 LOAD EQUAL TO 1.5 TIMES THE DESIGN
 PRESSURE. DADE COUNTY & SBCCI REPORTS
 ARE ACCEPTED.
  
 PROVIDE STORM PANEL INFORMATION WITH
 INSTALLATION SCHEDULE AND KEY PLAN WITH
 SPECIFIC ANCHORS AND MOUNTING TO BE USED
 FOR ALL NON-IMPACT GLAZING.
 FBC 1606.1.4.
  
 FL BLD CODE 2001 SECTION 103.6,
 1606.1.4, 1707.4 & 3401.7.2.4.
 PROCEDURES: 1(B) A COMPLETE INSTALLATION
 SCHEDULE SUMMARIZING & IDENTIFYING
 OPENING SIZES, STORY HEIGHTS, UNIT MARK
 NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM
 BAR REINFORCING REQUIREMENTS, WALL PRES-
 SURE ZONES, SLAT TYPES, ETC., SHALL BE
 SUBMITTED AT TIME OF PERMIT APPLICATION
 TO FACILITATE PLAN REVIEW AND PERMIT
 ISSUANCE.
  
 1503.4.4 PROTECTION AGAINST DECAY &
 TERMITES. CONDENSATE LINES & ROOF DOWN
 SPOUTS SHALL DISCHARGE AT LEAST 1 FT.
 AWAY FROM THE STRUCTURE SIDEWALL,
 WHETHER BY UNDERGROUND PIPING, TAIL EX-
 TENSIONS, OR SPLASH BLOCKS.
  
 RAKE BEAM ADD INFORMATION REQUIRED,
 MINIMUM BEAM SIZE, REBAR?
  
 BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A
 DESCRIPTION OF THE REVISION MADE, IDEN-
 TIFYING THE SHEET OR SPECIFICATION PAGE
 WHERE THE CHANGES CAN BE FOUND, WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU
 FOR YOUR ANTICIPATED COOPERATION.
 JIM WITMER
 PLAN REVIEW
 TEL: (561)659-8096 EX.8412
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-06-25 Cont ID  
Sent By dpalmer Date 2003-06-25 Time 16:56 Rev Time 0.25
Received By dpalmer Date 2003-06-25 Time 16:56 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2003-06-12 Cont ID  
Sent By pkrauss Date 2003-06-18 Time 17:05 Rev Time 0.50
Received By dpalmer Date 2003-06-12 Time 15:24 Sent To P
Notes
2003-06-12 00:00:00***************** UNSAT *************
  
 1)NOTE: PLEASE SEE NOTES FROM FIRST
 REVIEW. SAME PLANS WERE SUBMITTED BACK
 WITH NO CORRECTIONS MADE. PLEASE
 ADDRESS ORIGINAL COMMENTS.
  
 2)NOTE: PLEASE SEE ATTACHED LETTER
 PERTAINING TO FS 553.80(2)(B)
 WITH RESPECT TO DESIGN PROFESSIONAL.
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2003-02-07 Cont ID  
Sent By shernand Date 2003-06-10 Time 16:13 Rev Time 0.50
Received By dpalmer Date 2003-02-07 Time 08:51 Sent To P
Notes
2003-02-07 00:00:00************ UNSAT *****************
  
 1)NOTE: PLEASE SEE FS/FAC, PLANS MUST
 BE SIGNED AND SEALED BY THE ENGINEER OF
 RECORD. 471.025.
  
 2)NOTE: PLEASE CORRELATE PANEL SCHEDULE
 AND LOAD CALCULATIONS, A/C LOAD SHOWS
 ONLY SHOW ONE 10KW AHU AND PANEL SCHED-
 -ULE SHOWS TWO.
  
 3)NOTE: PLEASE LIST THE REQ`D BEDROOM
 ARC FAULT CIRCUITS PER 210-12
  
 4)NOTE: IT IS NOTED ON RISER THAT METER
 IS EXISTING? PLEASE SUBMIT AIC RATING
 FOR NEW MCB PANEL. 110-9/215-5
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2003-10-03 Cont ID  
Sent By csiegber Date 2003-10-03 Time 10:54 Rev Time 0.00
Received By csiegber Date 2003-10-03 Time 10:54 Sent To B
Notes
2003-10-03 00:00:00TO JW DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-09-15 Cont ID  
Sent By csiegber Date 2003-09-15 Time 13:55 Rev Time 0.00
Received By csiegber Date 2003-09-15 Time 13:55 Sent To B
Notes
2003-09-15 00:00:00TO JW DESK
 TO JW DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-06-25 Cont ID  
Sent By dpalmer Date 2003-06-25 Time 16:56 Rev Time 0.00
Received By dpalmer Date 2003-06-25 Time 16:56 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-06-10 Cont ID  
Sent By shernand Date 2003-06-10 Time 16:13 Rev Time 0.00
Received By shernand Date 2003-06-10 Time 16:13 Sent To E
Notes
2003-06-10 00:00:00DP DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-02-10 Cont ID  
Sent By dpalmer Date 2003-02-10 Time 10:57 Rev Time 0.00
Received By dpalmer Date 2003-02-10 Time 10:57 Sent To B
Notes
2003-02-10 00:00:00TO RES BOX

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2003-07-01 Cont ID  
Sent By pkrauss Date 2003-07-01 Time 09:40 Rev Time 0.05
Received By pkrauss Date   Time   Sent To B
Notes
2003-07-01 00:00:00NO CHANGES APPROVED 6-18-03

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-06-18 Cont ID  
Sent By kstevens Date 2003-06-30 Time 15:38 Rev Time 0.25
Received By pkrauss Date 2003-06-18 Time 16:02 Sent To E
Notes
2003-06-18 00:00:00PROVISO:MECHANICAL PERMIT 03010699
  
 AIR HANDLER UNIT LOCATED IN THE ATTIC
 SHALL COMPLY WITH 2001 FBC CHAPTER 13
 SUB-CHAPTER 610.ABC.3.5.2:
  
 1.THE SERVICE PANEL OF THE EQUIPMENT
 IS LOCATED WITHIN SIX FEET OF AN ATTIC
 ACCESS.
 2.A DEVICE IS INSTALLED TO ALERT THE
 OWNER OR SHUT THE UNIT DOWN WHEN THE
 CONDENSATION DRAIN IS NOT WORKING
 PROPERLY.
 3.THE ATTIC ACCESS OPENING IS OF
 SUFFICIENT SIZE TO REPLACE THE AIR
 HANDLER.
 4.A NOTICE IS POSTED ON THE ELECTRIC
 SERVICE PANEL INDICATING TO THE HOME
 OWNER THAT THE AIR HANDLER IS LOCATED
 IN THE ATTIC.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2003-02-07 Cont ID  
Sent By kstevens Date 2003-06-17 Time 07:46 Rev Time 0.20
Received By pkrauss Date 2003-02-07 Time 15:12 Sent To  
Notes
2003-02-07 00:00:00NO MECHANICAL PLANS SUBMITTED FOR REVIEW
  
 PLEASE PROVIDE MECHANICAL INFORMATION
 (MAKE, MODEL, BTU'S OF AHU & SEER OF THE
 CONDENSER UNIT).
  
 PROVIDE COMPLETED FORM 600A TO SHOW
 COMPLIANCE WITH 2001 FBC CHAPTER 13
 SECTION 600.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop P PLUMBING
Rev No 3 Status P Date 2003-06-30 Cont ID  
Sent By kstevens Date 2003-06-30 Time 15:38 Rev Time 0.50
Received By kstevens Date 2003-06-30 Time 15:38 Sent To M
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2003-06-17 Cont ID  
Sent By dpalmer Date 2003-06-25 Time 16:56 Rev Time 0.50
Received By kstevens Date 2003-06-17 Time 07:35 Sent To M
Notes
2003-06-17 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1) SANITARY RISER DIAGRAM DOES NOT RE-
 FLECT THE FLOOR PLAN. FIRST FLOOR BATH-
 ROOM HAS A W/C, A BIDET, A SHOWER, AND A
 LAV. RISER ONLY SHOWS W/C AND A LAV.
 FIRST FLOOR FLOOR PLAN DOES NOT SHOW A
 WASH MACHINE OR LAUNDRY SINK, BUT THEY
 ARE SHOWN ON THE RISER DIAGRAM. THE SEC-
 OND FLOOR BATHROOM SHOWS A W/C, A BIDET,
 A SHOWER, AND A LAV, BUT THE RISER DIA-
 GRAM SHOWS A W/C, A TUB, AND A LAV.
 RISER DIAGRAM SHALL REFLECT THE FLOOR
 PLAN. SHOW ONLY THOSE FIXTURES THAT WILL
 BE ADDED TO SYSTEM ON THE FIRST AND SEC-
 OND FLOORS.SHEET 3 OF 6
 2) SHEET 5 0F 6 SECOND SANITARY RISER
 DIARGAM DOES NOT REFLECT THE FLOOR PLAN.
 FIRST FLOOR PLAN SHOWS A BIDET IN BATH-
 ROOM AND RISER DOES NOT SHOW A BIDET.
 SECOND FLOOR PLAN SHOWS A BIDET BUT
 RISER DIAGRAM SHOWS 2 WATER CLOSETS.
 ALSO BOTH BATHROOMS HAVE DRY HORIZONTAL
 VENTS WHICH ARE NOT ALLOWED PER SECTION
 905.3.
 3) SECTION 104.2.1 AS REQUIRED BY SEC
 104.3.1.1 OF THE CODE, TWO OR MORE COP-
 IES OF SPECIFICATIONS, AND OF DRAWINGS
 DRAWN TO SCALE WITH SUFFICIENT CLARITY
 AND DETAIL TO INDICATE THE NATURE AND
 OF THE WORK, SHALL ACCOMPANY THE APPLI-
 CATION FOR A PERMIT.
 4) SEE ATTACHED SHEET CONCERNING FLORIDA
 STATUTE 553.80(2)(B).
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377
 (561) 805-6721
 FAX (561) 653-2692

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-02-07 Cont ID  
Sent By dpalmer Date 2003-06-12 Time 15:25 Rev Time 0.50
Received By kstevens Date 2003-02-07 Time 12:51 Sent To M
Notes
2003-02-07 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1) SANITARY RISER DIAGRAM DOES NOT MEET
 CODE REQUIREMENTS. NO HORIZONTAL DRY
 VENTS, (905.3), LAVS NOT VENTED PROPERLY
 2) SANITARY RISER DIAGRAM DOES NOT RE-
 FLECT THE FLOOR PLAN. BIDET ON 1ST FLOOR
 NOT SHOWN. 2 WATER CLOSETS SHOWN ON 2ND
 FLOOR. ON FLOOR PLAN A BIDET IS SHOWN
 ON EACH FLOOR.
 3) SEE RED LINE AREAS ON SANT. RISER
 DIAGRAM, AND SEE ATTACHED SHEET FOR
 EXAMPLE OF AN APPROVED RISER DIAGRAM.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop Z ZONING
Rev No 2 Status P Date 2003-02-06 Cont ID  
Sent By lmartine Date 2003-02-06 Time 11:06 Rev Time 1.00
Received By lmartine Date   Time   Sent To E
Notes
2003-02-06 00:00:00SEE SURVEY FOR ZONING SIGN OFF

Review Stop Z ZONING
Rev No 1 Status F Date 2003-02-06 Cont ID  
Sent By sgraham Date 2003-02-06 Time 10:57 Rev Time 0.00
Received By sgraham Date   Time   Sent To  
Notes
2003-02-06 00:00:00DENIED, NEED SITE PLAN


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved